Information
JB Pritzker, Governor
Michele L Pankow, State Fire Marshal
Division of Petroleum & Chemical Safety
State of Illinois
Employment Opportunities
Ready Illinois
Find us on Facebook
UST
Search
Contractor Search
Permit Search
Disclaimer & Rules/Statutes
Disclaimer
Rules
Statutes
Statistics & Reports
Statistics
Red Tag Tanks
Blended Fuel Tanks
Federal Energy Act Reports
Help
Division of Petroleum & Chemical Safety
Facility Details
Facility Number:
3006041
Status:
Active
Facility Name:
H&S Gas and Food, Inc.
Address:
501 24th Street Rock Island, IL 61201
County:
Rock Island
Property Parcel:
07-36-301-001
Facility Type:
Attended Self-Service Station
Owner Type:
Private
Green Tag Decal:
Z000401
Green Tag Issue Date:
6/12/2024
Green Tag Expiration Date:
12/31/2026
Owner Details
Owner Name:
CK United, LLC
Owner Address:
300 N. Martingale Rd. Suite 750 Schaumburg, IL 60173
Owner Status:
Current Owner
Purchase Date:
4/26/2024
Type of Financial Responsibility:
Designated Savings Account
Financial Responsibility Reporting Due Date:
4/21/2026
Motor Fuel Dispensing Permits
MFD Permit Type
Issue Date
Expiration Date
Self Service
6/12/2024
12/31/2026
Owner Summary
Click for Facility/Tank Ownership history
Owner Number
Owner Name
Owner Status
Purchase Date
U0040495
CK United, LLC
Current Owner
4/26/2024
U0030949
Mac's Convenience Stores, LLC
Former Owner
6/29/2021
U0029789
Clark Retail Enterprises, Inc.
Former Owner
3/7/2001
U0015991
Wareco Service, Inc.
Former Owner
Permits (Unexpired)
Click for permit history
No Active Permits Found
Notice of Violatlions (Current)
No Notice of Violations Found
IEMA Numbers Associated with the Facility
IEMA Number
Inspection Date
Inspection Type
Permit Number
94-1542
7/12/1994
Removal Log
LUST
Fund Eligibility and Deductibility Determinations
IEMA Number
Status
OSFM Received Date
OSFM Response Date
Deductible
Letter
94-1542
Eligible
10/19/1995
11/27/1995
$10,000
94-1542
Eligible
5/25/2006
6/27/2006
$10,000
Pay Tank Fees Online
Tank Information
Tank Number 1
Capacity:
6000
Petroleum Use:
Product:
Gasoline
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
7/12/1994
OSFM
First Notify Date:
12/10/1985
Abandoned Material:
Current Age:
21
Abandoned Date:
Install Date:
1/1/1973
Red Tag Issue Date:
Last Used Date:
7/12/1994
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 2
Capacity:
6000
Petroleum Use:
Product:
Gasoline
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
7/12/1994
OSFM
First Notify Date:
12/10/1985
Abandoned Material:
Current Age:
21
Abandoned Date:
Install Date:
1/1/1973
Red Tag Issue Date:
Last Used Date:
7/12/1994
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 3
Capacity:
4000
Petroleum Use:
Product:
Gasoline
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
7/12/1994
OSFM
First Notify Date:
12/10/1985
Abandoned Material:
Current Age:
21
Abandoned Date:
Install Date:
1/1/1973
Red Tag Issue Date:
Last Used Date:
7/12/1994
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 5
Capacity:
6000
Petroleum Use:
Product:
Diesel Fuel
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
7/12/1994
OSFM
First Notify Date:
12/10/1985
Abandoned Material:
Current Age:
15
Abandoned Date:
Install Date:
1/1/1979
Red Tag Issue Date:
Last Used Date:
7/12/1994
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 6
Capacity:
275
Petroleum Use:
Product:
Used Oil
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Exempt
Removed Date:
7/12/1994
OSFM
First Notify Date:
12/5/1994
Abandoned Material:
Current Age:
23
Abandoned Date:
Install Date:
1/1/1971
Red Tag Issue Date:
Last Used Date:
12/31/1973
Fee Due:
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 7
Capacity:
10000
Petroleum Use:
Product:
Gasoline - Regular
CERCLA Substance:
Status:
Currently in use
CAS Code:
Regulated Status:
Federal
Removed Date:
OSFM
First Notify Date:
12/5/1994
Abandoned Material:
Current Age:
31
Abandoned Date:
Install Date:
8/2/1994
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Flexible Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Fiberglass Non-Corrosive
N/A
N/A
Leak Detect - Piping
Electronic Pressurized Line Leak Detection
7/14/2025
7/14/2026
Leak Detect - Tank
Automatic Tank Gauging Veeder Root TLS 350 Plus with CSLD
7/14/2025
7/14/2026
Leak Detect - Tank
Hydrostatic Reservoir Interstitial Monitoring Sensors
7/14/2025
7/14/2026
Overfill Prev Device
Overfill Drop Tube Valve
3/8/2022
3/8/2025
Piping
Flexible Double Wall Environ Geo Flex
N/A
N/A
Piping
Single Wall STP/Tanktop Sump
4/17/2024
4/17/2027
Leak Detect - Piping
Sump Sensor
7/14/2025
7/14/2026
Spill Contain Device
Single Wall Spill Bucket
2/1/2024
2/1/2027
Tank
Fiberglass Double Wall Owens Corning
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Piping
Flexible Double Wall Environ Geo Flex
Precision Test (Piping)
Pass
2/1/2024
Tank Number 8
Capacity:
10000
Petroleum Use:
Product:
Gasoline - Regular
CERCLA Substance:
Status:
Currently in use
CAS Code:
Regulated Status:
Federal
Removed Date:
OSFM
First Notify Date:
12/5/1994
Abandoned Material:
Current Age:
31
Abandoned Date:
Install Date:
8/2/1994
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Flexible Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Fiberglass Non-Corrosive
N/A
N/A
Leak Detect - Piping
Electronic Pressurized Line Leak Detection
7/14/2025
7/14/2026
Leak Detect - Tank
Automatic Tank Gauging Veeder Root TLS 350 Plus with CSLD
7/14/2025
7/14/2026
Leak Detect - Tank
Hydrostatic Reservoir Interstitial Monitoring Sensors
7/14/2025
7/14/2026
Overfill Prev Device
Overfill Drop Tube Valve
3/8/2022
3/8/2025
Piping
Flexible Double Wall Environ Geo Flex
N/A
N/A
Piping
Single Wall STP/Tanktop Sump
4/17/2024
4/17/2027
Leak Detect - Piping
Sump Sensor
7/14/2025
7/14/2026
Spill Contain Device
Single Wall Spill Bucket
2/1/2024
2/1/2027
Tank
Fiberglass Double Wall Owens Corning
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Piping
Flexible Double Wall Environ Geo Flex
Precision Test (Piping)
Pass
2/1/2024
Tank Number 9
Capacity:
10000
Petroleum Use:
Product:
Gasoline - Premium
CERCLA Substance:
Status:
Currently in use
CAS Code:
Regulated Status:
Federal
Removed Date:
OSFM
First Notify Date:
12/5/1994
Abandoned Material:
Current Age:
31
Abandoned Date:
Install Date:
8/2/1994
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Flexible Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Fiberglass Non-Corrosive
N/A
N/A
Leak Detect - Piping
Electronic Pressurized Line Leak Detection
7/14/2025
7/14/2026
Leak Detect - Tank
Automatic Tank Gauging Veeder Root TLS 350 Plus with CSLD
7/14/2025
7/14/2026
Leak Detect - Tank
Hydrostatic Reservoir Interstitial Monitoring Sensors
7/14/2025
7/14/2026
Overfill Prev Device
Overfill Drop Tube Valve
3/8/2022
3/8/2025
Piping
Flexible Double Wall Environ Geo Flex
N/A
N/A
Piping
Single Wall STP/Tanktop Sump
4/17/2024
4/17/2027
Leak Detect - Piping
Sump Sensor
7/14/2025
7/14/2026
Spill Contain Device
Single Wall Spill Bucket
2/1/2024
2/1/2027
Tank
Fiberglass Double Wall Owens Corning
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Piping
Flexible Double Wall Environ Geo Flex
Precision Test (Piping)
Pass
2/1/2024
Dispenser Information
Name\ID 1/2
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
Leak Detect - Piping
Piping Sump Sensors Not Regulated Not Installed
N/A
N/A
Name\ID 3/4
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
Leak Detect - Piping
Piping Sump Sensors Not Regulated Not Installed
N/A
N/A
Name\ID 5/6
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
Leak Detect - Piping
Piping Sump Sensors Not Regulated Not Installed
N/A
N/A
MFD
Motorfuel Dispensing Forms
No Forms Found