Information
JB Pritzker, Governor
James A. Rivera, State Fire Marshal
Division of Petroleum & Chemical Safety
State of Illinois
Employment Opportunities
Ready Illinois
Find us on Facebook
UST
Search
Contractor Search
Permit Search
Disclaimer & Rules/Statutes
Disclaimer
Rules
Statutes
Statistics & Reports
Statistics
Red Tag Tanks
Blended Fuel Tanks
Federal Energy Act Reports
Help
Division of Petroleum & Chemical Safety
Facility Details
Facility Number:
3002148
Status:
Closed
Facility Name:
BP Macomb
Address:
225 West Jackson
Macomb, IL 61455
County:
McDonough
Property Parcel:
11-400-047-00
Facility Type:
Attended Self-Service Station
Owner Type:
Private
Green Tag Decal:
N002387
Green Tag Issue Date:
8/8/2012
Green Tag Expiration Date:
12/31/2014
Owner Details
Owner Name:
Nadir Khan
Owner Address:
113 Fawn Ridge
Macomb, IL 61455
Owner Status:
Current Owner
Purchase Date:
2/22/2010
Type of Financial Responsibility:
Financial Responsibility Reporting Due Date:
Motor Fuel Dispensing Permits
MFD Permit Type
Issue Date
Expiration Date
Self Service
8/8/2012
12/31/2014
Owner Summary
Click for Facility/Tank Ownership history
Owner Number
Owner Name
Owner Status
Purchase Date
U0038585
Khan, Nadir
Current Owner
2/22/2010
U0035824
T $ Ventures, Inc.
Former Owner
2/22/2010
U0025095
Norm's Amoco/BP
Former Owner
8/15/1993
U0001962
Brillhart Rebecca J
Former Owner
12/31/1967
Permits (Unexpired)
Click for permit history
No Active Permits Found
Notice of Violations (Current)
No Notice of Violations Found
IEMA Numbers Associated with the Facility
IEMA Number
Inspection Date
Inspection Type
Permit Number
16-1148
1/25/2017
Removal Log
00063-2017REM
LUST
Fund Eligibility and Deductibility Determinations
IEMA Number
Status
OSFM Received Date
OSFM Response Date
Deductible
Letter
20161148
Eligible
2/2/2017
2/3/2017
$5,000
Letter
Pay Tank Fees Online
Tank Information
Tank Number 1
Capacity:
6000
Petroleum Use:
Product:
Gasoline
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
7/20/1988
OSFM
First Notify Date:
3/17/1986
Abandoned Material:
Current Age:
27
Abandoned Date:
Install Date:
Red Tag Issue Date:
Last Used Date:
7/20/1988
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 2
Capacity:
8000
Petroleum Use:
Product:
Gasoline
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
7/20/1988
OSFM
First Notify Date:
3/17/1986
Abandoned Material:
Current Age:
35
Abandoned Date:
Install Date:
Red Tag Issue Date:
Last Used Date:
7/20/1988
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 3
Capacity:
8000
Petroleum Use:
Product:
Gasoline
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
7/20/1988
OSFM
First Notify Date:
3/17/1986
Abandoned Material:
Current Age:
35
Abandoned Date:
Install Date:
Red Tag Issue Date:
Last Used Date:
7/20/1988
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 4
Capacity:
500
Petroleum Use:
Product:
Used Oil
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
OSFM
First Notify Date:
3/17/1986
Abandoned Material:
Current Age:
35
Abandoned Date:
Install Date:
Red Tag Issue Date:
Last Used Date:
1/1/1993
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 5
Capacity:
300
Petroleum Use:
Consumptive Use on Premises for Heating
Product:
Heating Oil
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
State
Removed Date:
7/20/1988
OSFM
First Notify Date:
3/17/1986
Abandoned Material:
Current Age:
35
Abandoned Date:
Install Date:
Red Tag Issue Date:
Last Used Date:
10/1/1980
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 6
Capacity:
8000
Petroleum Use:
Product:
Gasoline
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
1/25/2017
OSFM
First Notify Date:
11/25/1992
Abandoned Material:
Current Age:
28
Abandoned Date:
Install Date:
8/8/1988
Red Tag Issue Date:
Last Used Date:
2/1/2013
Fee Due:
$0.00
Product Date:
8/8/1988
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Sacrificial Anode Flex Connector
6/10/2010
6/10/2013
Corrosion Prot - Piping
Fiberglass Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Fiberglass Non-Corrosive
N/A
N/A
Leak Detect - Piping
Mechanical Pressurized Line Leak Detection
6/26/2012
6/26/2013
Leak Detect - Tank
Automatic Tank Gauging Veeder Root TLS 250
Overfill Prev Device
Ball Float Vent Valve
Piping
Fiberglass Single Wall Piping Ameron
N/A
N/A
Spill Contain Device
Single Wall Spill Bucket
Tank
Fiberglass Single Wall
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 7
Capacity:
8000
Petroleum Use:
Product:
Gasoline
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
1/25/2017
OSFM
First Notify Date:
11/25/1992
Abandoned Material:
Current Age:
28
Abandoned Date:
Install Date:
8/8/1988
Red Tag Issue Date:
Last Used Date:
2/1/2013
Fee Due:
$0.00
Product Date:
8/8/1988
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Sacrificial Anode Flex Connector
6/10/2010
6/10/2013
Corrosion Prot - Piping
Fiberglass Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Fiberglass Non-Corrosive
N/A
N/A
Leak Detect - Piping
Mechanical Pressurized Line Leak Detection
6/26/2012
6/26/2013
Leak Detect - Tank
Automatic Tank Gauging Veeder Root TLS 250
Overfill Prev Device
Ball Float Vent Valve
Piping
Fiberglass Single Wall Piping Ameron
N/A
N/A
Spill Contain Device
Single Wall Spill Bucket
Tank
Fiberglass Single Wall
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 8
Capacity:
8000
Petroleum Use:
Product:
Gasoline
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
1/25/2017
OSFM
First Notify Date:
11/25/1992
Abandoned Material:
Current Age:
28
Abandoned Date:
Install Date:
8/8/1988
Red Tag Issue Date:
Last Used Date:
2/1/2013
Fee Due:
$0.00
Product Date:
8/8/1988
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Sacrificial Anode Flex Connector
6/10/2010
6/10/2013
Corrosion Prot - Piping
Fiberglass Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Fiberglass Non-Corrosive
N/A
N/A
Leak Detect - Piping
Mechanical Pressurized Line Leak Detection
6/26/2012
6/26/2013
Leak Detect - Tank
Automatic Tank Gauging Veeder Root TLS 250
Overfill Prev Device
Ball Float Vent Valve
Piping
Fiberglass Single Wall Piping Ameron
N/A
N/A
Spill Contain Device
Single Wall Spill Bucket
Tank
Fiberglass Single Wall
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 9
Capacity:
560
Petroleum Use:
Product:
Used Oil
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
8/21/2014
OSFM
First Notify Date:
11/25/1992
Abandoned Material:
Current Age:
26
Abandoned Date:
Install Date:
8/8/1988
Red Tag Issue Date:
Last Used Date:
12/31/2008
Fee Due:
$0.00
Product Date:
8/8/1988
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Dispenser Information
MFD
Motorfuel Dispensing Forms
No Forms Found