Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 3001625
Status: Closed
Facility Name: Alcast Company
Address: 8821 North University Peoria, IL 61615
County: Peoria
Property Parcel:
Facility Type: Industrial / Manufacturing
Owner Type: Private
Green Tag Decal: N002440
Green Tag Issue Date: 12/3/2012
Green Tag Expire Date: 12/31/2014
MFD Type: N/A

Owner Details

Owner Name: Alcast Company
Owner Address: 8821 North University Peoria, IL 61615
Owner Status: Current Owner
Purchase Date: 4/20/1988
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 8/21/2015

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0000329 Alcast Company Current Owner 4/20/1988

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 2000 Petroleum Use: Back-up Generator
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 9/23/2014
OSFM First Notify Date: 4/20/1988 Abandoned Material:
Current Age: 26 Abandoned Date:
Install Date: 4/20/1988 Red Tag Issue Date:
Last Used Date: 7/1/2014 Fee Due: $0.00
Product Date: 4/20/1988

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank STIP3 Cathodic Protection with Dielectric Coating 1/16/2012 1/16/2015
Leak Detect - Piping European with No Test Req Suction Not applicable Not applicable
Leak Detect - Piping Sump Sensor 1/16/2012 1/16/2013
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 No passing test found No passing test found
Overfill Prev Device Overfill Drop Tube Valve No passing test found No passing test found
Piping Fiberglass Secondary Containment Copper Primary with Non Corrosive Secondary Not applicable Not applicable
Spill Contain Device Single Wall Spill Bucket No passing test found No passing test found
Tank STIP3 Single Wall Not applicable Not applicable

Additional Tests

No Tests Listed


Failed test = the latest test has failed.

Not applicable = a test does not apply to this equipment type or configuration.

No passing test found = a passing test is expected but was not found from the source data.


Dispenser Information




Failed test = the latest test has failed.

Not applicable = a test does not apply to this equipment type or configuration.

No passing test found = a passing test is expected but was not found from the source data.


MFD Motorfuel Dispensing Forms