Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2047753
Status: Installed/Not in Use
Facility Name: Lenny's Gas N Wash 65th & Central, LLC
Address: 5611 W 65th Street
Bedford Park, IL 60638
County: Cook
Property Parcel: 19-20-217-068-0000
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal:
Green Tag Issue Date:
Green Tag Expiration Date:

Owner Details

Owner Name: Lenny's Gas N Wash 65th & Central, LLC
Owner Address: 8200 W 185th St. Unit K
Tinley Park, IL 60487
Owner Status: Current Owner
Purchase Date:
Type of Financial Responsibility: Designated Savings Account
Financial Responsibility Reporting Due Date: 4/16/2026

Motor Fuel Dispensing Permits

No MFD Permits Found

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0041208 Lenny's Gas N Wash 65th & Central, LLC Current Owner

Permits (Unexpired)

Click for permit history
Permit Number Type Status OSFM Receive Date Issue Date Expiration Date Documents
01627-2024INS Install Approved / Revised 12/17/2024 12/17/2024 6/17/2025 Documents

Notice of Violations (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 20000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Installed/Not in Use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/14/2025 Abandoned Material:
Current Age: 0 Abandoned Date:
Install Date: 7/31/2024 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Leak Detect - Piping Electronic Pressurized Line Leak Detection 5/15/2025 5/15/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 Plus 5/15/2025 5/15/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 5/15/2025 5/15/2026
Overfill Prev Device Overfill Drop Tube Valve 4/11/2025 4/11/2028
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 1/31/2025 1/31/2028
Leak Detect - Piping Sump Sensor with positive shutdown 5/15/2025 5/15/2026
Spill Contain Device Double Wall Spill Bucket 1/31/2025 1/31/2028
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 5/15/2025
Tank Fiberglass Double Wall XERXES Precision Test (Tank) Pass 5/15/2025



Tank Number 2

Capacity: 6000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Installed/Not in Use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/14/2025 Abandoned Material:
Current Age: 0 Abandoned Date:
Install Date: 7/31/2024 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Leak Detect - Piping Electronic Pressurized Line Leak Detection 5/15/2025 5/15/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 Plus 5/15/2025 5/15/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 5/15/2025 5/15/2026
Overfill Prev Device Overfill Drop Tube Valve 4/11/2025 4/11/2028
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 1/31/2025 1/31/2028
Leak Detect - Piping Sump Sensor with positive shutdown 5/15/2025 5/15/2026
Spill Contain Device Double Wall Spill Bucket 1/31/2025 1/31/2028
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 5/15/2025
Tank Fiberglass Double Wall XERXES Precision Test (Tank) Pass 5/15/2025



Tank Number 3

Capacity: 10000 Petroleum Use:
Product: E85 CERCLA Substance:
Status: Installed/Not in Use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/14/2025 Abandoned Material:
Current Age: 0 Abandoned Date:
Install Date: 7/31/2024 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Leak Detect - Piping Electronic Pressurized Line Leak Detection 5/15/2025 5/15/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 Plus 5/15/2025 5/15/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 5/15/2025 5/15/2026
Overfill Prev Device Overfill Drop Tube Valve 4/11/2025 4/11/2028
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 1/31/2025 1/31/2028
Leak Detect - Piping Sump Sensor with positive shutdown 5/15/2025 5/15/2026
Spill Contain Device Double Wall Spill Bucket 1/31/2025 1/31/2028
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 5/15/2025
Tank Fiberglass Double Wall XERXES Precision Test (Tank) Pass 5/15/2025



Tank Number 4

Capacity: 6000 Petroleum Use: None
Product: Diesel Fuel CERCLA Substance:
Status: Installed/Not in Use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/14/2025 Abandoned Material:
Current Age: 0 Abandoned Date:
Install Date: 7/31/2024 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Leak Detect - Piping Electronic Pressurized Line Leak Detection 5/15/2025 5/15/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 Plus 5/15/2025 5/15/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 5/15/2025 5/15/2026
Overfill Prev Device Overfill Drop Tube Valve 4/11/2025 4/11/2028
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 1/31/2025 1/31/2028
Leak Detect - Piping Sump Sensor with positive shutdown 5/15/2025 5/15/2026
Spill Contain Device Double Wall Spill Bucket 1/31/2025 1/31/2028
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 5/15/2025
Tank Fiberglass Double Wall XERXES Precision Test (Tank) Pass 5/15/2025



Tank Number 5

Capacity: 20000 Petroleum Use: None
Product: Diesel Fuel CERCLA Substance:
Status: Installed/Not in Use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/14/2025 Abandoned Material:
Current Age: 0 Abandoned Date:
Install Date: 8/7/2024 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Leak Detect - Piping Electronic Pressurized Line Leak Detection 5/15/2025 5/15/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 Plus 5/15/2025 5/15/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 5/15/2025 5/15/2026
Overfill Prev Device Overfill Drop Tube Valve 4/11/2025 4/11/2028
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 1/31/2025 1/31/2028
Leak Detect - Piping Sump Sensor with positive shutdown 5/15/2025 5/15/2026
Spill Contain Device Double Wall Spill Bucket 1/31/2025 1/31/2028
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 5/15/2025
Tank Fiberglass Double Wall XERXES Precision Test (Tank) Pass 5/15/2025

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 1/31/2025 1/31/2028
Leak Detect - Piping Sump Sensor with positive shutdown 5/15/2025 5/15/2026



Name\ID 11/12

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 1/31/2025 1/31/2028
Leak Detect - Piping Sump Sensor with positive shutdown 5/15/2025 5/15/2026



Name\ID 13/14

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 1/31/2025 1/31/2028
Leak Detect - Piping Sump Sensor with positive shutdown 5/15/2025 5/15/2026



Name\ID 15/16

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 1/31/2025 1/31/2028
Leak Detect - Piping Sump Sensor with positive shutdown 5/15/2025 5/15/2026



Name\ID 17/18

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 1/31/2025 1/31/2028
Leak Detect - Piping Sump Sensor with positive shutdown 5/15/2025 5/15/2026



Name\ID 19/20

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 1/31/2025 1/31/2028
Leak Detect - Piping Sump Sensor with positive shutdown 5/15/2025 5/15/2026



Name\ID 21/22

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 1/31/2025 1/31/2028
Leak Detect - Piping Sump Sensor with positive shutdown 5/15/2025 5/15/2026



Name\ID 23/24

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 1/31/2025 1/31/2028
Leak Detect - Piping Sump Sensor with positive shutdown 5/15/2025 5/15/2026



Name\ID 25/26

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 1/31/2025 1/31/2028
Leak Detect - Piping Sump Sensor with positive shutdown 5/15/2025 5/15/2026



Name\ID 27/28

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 1/31/2025 1/31/2028
Leak Detect - Piping Sump Sensor with positive shutdown 5/15/2025 5/15/2026



Name\ID 29M

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 1/31/2025 1/31/2028
Leak Detect - Piping Sump Sensor with positive shutdown 5/15/2025 5/15/2026



Name\ID 29S/30M

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 1/31/2025 1/31/2028
Leak Detect - Piping Sump Sensor with positive shutdown 5/15/2025 5/15/2026



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 1/31/2025 1/31/2028
Leak Detect - Piping Sump Sensor with positive shutdown 5/15/2025 5/15/2026



Name\ID 30S/31M

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 1/31/2025 1/31/2028
Leak Detect - Piping Sump Sensor with positive shutdown 5/15/2025 5/15/2026



Name\ID 31S/32M

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 1/31/2025 1/31/2028
Leak Detect - Piping Sump Sensor with positive shutdown 5/15/2025 5/15/2026



Name\ID 32S

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 1/31/2025 1/31/2028
Leak Detect - Piping Sump Sensor with positive shutdown 5/15/2025 5/15/2026



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 1/31/2025 1/31/2028
Leak Detect - Piping Sump Sensor with positive shutdown 5/15/2025 5/15/2026



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 1/31/2025 1/31/2028
Leak Detect - Piping Sump Sensor with positive shutdown 5/15/2025 5/15/2026



Name\ID 9/10

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 1/31/2025 1/31/2028
Leak Detect - Piping Sump Sensor with positive shutdown 5/15/2025 5/15/2026

MFD Motorfuel Dispensing Forms

No Forms Found