Information
JB Pritzker, Governor
James A. Rivera, State Fire Marshal
Division of Petroleum & Chemical Safety
State of Illinois
Employment Opportunities
Ready Illinois
Find us on Facebook
UST
Search
Contractor Search
Permit Search
Disclaimer & Rules/Statutes
Disclaimer
Rules
Statutes
Statistics & Reports
Statistics
Red Tag Tanks
Blended Fuel Tanks
Federal Energy Act Reports
Help
Division of Petroleum & Chemical Safety
Facility Details
Facility Number:
2047734
Status:
Installed/Not in Use
Facility Name:
Speed Trek Joliet
Address:
2565 Plainfield Rd.
Joliet, IL 60435
County:
Will
Property Parcel:
06-03-25-423-035-0000
Facility Type:
Attended Self-Service Station
Owner Type:
Private
Green Tag Decal:
Green Tag Issue Date:
Green Tag Expiration Date:
Owner Details
Owner Name:
OM Joliet Realty LLC
Owner Address:
200 S. Frontage Rd.
Suite 310
Burr Ridge, IL 60527
Owner Status:
Current Owner
Purchase Date:
11/13/2023
Type of Financial Responsibility:
Commercial Insurance
Financial Responsibility Reporting Due Date:
5/16/2026
Motor Fuel Dispensing Permits
No MFD Permits Found
Owner Summary
Click for Facility/Tank Ownership history
Owner Number
Owner Name
Owner Status
Purchase Date
U0041496
OM Joliet Realty LLC
Current Owner
11/13/2023
U0039701
OM Group
Former Owner
Permits (Unexpired)
Click for permit history
Permit Number
Type
Status
OSFM Receive Date
Issue Date
Expiration Date
Documents
00509-2025INS
Install
Approved / Revised
4/28/2025
4/29/2025
10/29/2025
Documents
Notice of Violations (Current)
No Notice of Violations Found
IEMA Numbers Associated with the Facility
No IEMA Numbers Found
LUST
Fund Eligibility and Deductibility Determinations
No Applications Found
Pay Tank Fees Online
Tank Information
Tank Number 1
Capacity:
20000
Petroleum Use:
Product:
Gasoline - Regular
CERCLA Substance:
Status:
Installed/Not in Use
CAS Code:
Regulated Status:
Federal
Removed Date:
OSFM
First Notify Date:
5/20/2025
Abandoned Material:
Current Age:
0
Abandoned Date:
Install Date:
6/27/2024
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
4/15/2025
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Leak Detect - Tank
Automatic Tank Gauging Veeder Root TLS 450 Plus with CSLD
4/23/2025
4/23/2026
Leak Detect - Tank
Non-Discriminating Interstitial Monitoring Sensors
4/23/2025
4/23/2026
Overfill Prev Device
Overfill Alarm
4/23/2025
4/23/2028
Piping
Flexible Double Wall A.P.T. Poly Tech P150SC
N/A
N/A
Piping
Single Wall STP/Tanktop Sump
4/23/2025
4/23/2028
Leak Detect - Piping
Sump Sensor with positive shutdown
4/23/2025
4/23/2026
Spill Contain Device
Double Wall Spill Bucket
9/12/2024
9/12/2027
Tank
Fiberglass Double Wall XERXES
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Piping
Flexible Double Wall A.P.T. Poly Tech P150SC
Precision Test (Piping)
Pass
4/30/2025
Tank
Fiberglass Double Wall XERXES
Precision Test (Tank)
Pass
4/30/2025
Tank Number 2
Capacity:
8000
Petroleum Use:
Product:
Gasoline - Premium
CERCLA Substance:
Status:
Installed/Not in Use
CAS Code:
Regulated Status:
Federal
Removed Date:
OSFM
First Notify Date:
5/20/2025
Abandoned Material:
Current Age:
0
Abandoned Date:
Install Date:
6/27/2024
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
4/15/2025
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Leak Detect - Tank
Automatic Tank Gauging Veeder Root TLS 450 Plus with CSLD
4/23/2025
4/23/2026
Leak Detect - Tank
Non-Discriminating Interstitial Monitoring Sensors
4/23/2025
4/23/2026
Overfill Prev Device
Overfill Alarm
4/23/2025
4/23/2028
Piping
Flexible Double Wall A.P.T. Poly Tech P150SC
N/A
N/A
Piping
Single Wall STP/Tanktop Sump
4/23/2025
4/23/2028
Leak Detect - Piping
Sump Sensor with positive shutdown
4/23/2025
4/23/2026
Spill Contain Device
Double Wall Spill Bucket
9/12/2024
9/12/2027
Tank
Fiberglass Double Wall XERXES
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Piping
Flexible Double Wall A.P.T. Poly Tech P150SC
Precision Test (Piping)
Pass
4/30/2025
Tank
Fiberglass Double Wall XERXES
Precision Test (Tank)
Pass
4/30/2025
Tank Number 3
Capacity:
12000
Petroleum Use:
Product:
Diesel Fuel
CERCLA Substance:
Status:
Installed/Not in Use
CAS Code:
Regulated Status:
Federal
Removed Date:
OSFM
First Notify Date:
5/20/2025
Abandoned Material:
Current Age:
0
Abandoned Date:
Install Date:
7/3/2024
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
4/15/2025
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Leak Detect - Tank
Automatic Tank Gauging Veeder Root TLS 450 Plus with CSLD
4/23/2025
4/23/2026
Leak Detect - Tank
Non-Discriminating Interstitial Monitoring Sensors
4/23/2025
4/23/2026
Overfill Prev Device
Overfill Alarm
4/23/2025
4/23/2028
Piping
Flexible Double Wall A.P.T. Poly Tech P200SC
N/A
N/A
Piping
Single Wall STP/Tanktop Sump
4/23/2025
4/23/2028
Leak Detect - Piping
Sump Sensor with positive shutdown
4/23/2025
4/23/2026
Spill Contain Device
Double Wall Spill Bucket
9/12/2024
9/12/2027
Tank
Fiberglass Double Wall XERXES
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Piping
Flexible Double Wall A.P.T. Poly Tech P200SC
Precision Test (Piping)
Pass
4/30/2025
Tank
Fiberglass Double Wall XERXES
Precision Test (Tank)
Pass
4/30/2025
Dispenser Information
Name\ID 1/2
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
4/23/2025
4/23/2028
Leak Detect - Piping
Sump Sensor with positive shutdown
4/23/2025
4/23/2026
Name\ID 11/12
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
4/23/2025
4/23/2028
Leak Detect - Piping
Sump Sensor with positive shutdown
4/23/2025
4/23/2026
Name\ID 13/14
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
4/23/2025
4/23/2028
Leak Detect - Piping
Sump Sensor with positive shutdown
4/23/2025
4/23/2026
Name\ID 15/16
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
4/23/2025
4/23/2028
Leak Detect - Piping
Sump Sensor with positive shutdown
4/23/2025
4/23/2026
Name\ID 3/4
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
4/23/2025
4/23/2028
Leak Detect - Piping
Sump Sensor with positive shutdown
4/23/2025
4/23/2026
Name\ID 5/6
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
4/23/2025
4/23/2028
Leak Detect - Piping
Sump Sensor with positive shutdown
4/23/2025
4/23/2026
Name\ID 7/8
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
4/23/2025
4/23/2028
Leak Detect - Piping
Sump Sensor with positive shutdown
4/23/2025
4/23/2026
Name\ID 9/10
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
9/12/2024
9/12/2027
Leak Detect - Piping
Sump Sensor with positive shutdown
4/23/2025
4/23/2026
Name\ID Master 17
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
4/23/2025
4/23/2028
Leak Detect - Piping
Sump Sensor with positive shutdown
4/23/2025
4/23/2026
Name\ID Master 18
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
4/23/2025
4/23/2028
Leak Detect - Piping
Sump Sensor with positive shutdown
4/23/2025
4/23/2026
Name\ID Satellite
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
4/23/2025
4/23/2028
Leak Detect - Piping
Sump Sensor with positive shutdown
4/23/2025
4/23/2026
MFD
Motorfuel Dispensing Forms
Facility Number
Name
City
Received Date
Letter
2047734
Speed Trek Joliet
Joliet
04/29/2025
Letter
Form