Facility Details
Facility Number:
2047650
Status:
Active
Facility Name:
Speed Trek
Address:
2020 E. Laraway Road
New Lenox, IL 60451
County:
Will
Property Parcel:
15-08-36-100-005-0000
Facility Type:
Attended Self-Service Station
Owner Type:
Private
Green Tag Decal:
Z001317
Green Tag Issue Date:
8/5/2024
Green Tag Expiration Date:
12/31/2026
Owner Details
Owner Name:
Terraco-OM Real Estate Partners - New Lenox, LLC
Owner Address:
3201 Old Glenview Road, Suite 300
Wilmette, IL 60091
Owner Status:
Current Owner
Purchase Date:
11/7/2022
Type of Financial Responsibility:
Commercial Insurance
Financial Responsibility Reporting Due Date:
3/22/2025
Motor Fuel Dispensing Permits
MFD Permit Type
Issue Date
Expiration Date
Self Service
8/5/2024
12/31/2026
Owner Summary
Click for Facility/Tank Ownership history
Owner Number
Owner Name
Owner Status
Purchase Date
U0041134
Terraco-OM Real Estate Partners - New Lenox, LLC
Current Owner
11/7/2022
U0039701
OM Group
Former Owner
Permits (Unexpired)
Click for permit history
Permit Number
Type
Status
OSFM Receive Date
Issue Date
Expiration Date
Documents
00459-2025UPG
Upgrade
Approved / Issued
4/18/2025
4/19/2025
10/21/2025
Documents
Notice of Violations (Current)
No Notice of Violations Found
IEMA Numbers Associated with the Facility
No IEMA Numbers Found
LUST
Fund Eligibility and Deductibility Determinations
No Applications Found
Pay Tank Fees Online
Tank Information
Tank Number 1
Capacity:
20000
Petroleum Use:
Product:
Gasoline - Regular
CERCLA Substance:
Status:
Currently in use
CAS Code:
Regulated Status:
Federal
Removed Date:
OSFM
First Notify Date:
3/4/2024
Abandoned Material:
Current Age:
1
Abandoned Date:
Install Date:
10/5/2023
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Flexible Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Fiberglass Non-Corrosive
N/A
N/A
Leak Detect - Piping
Electronic Pressurized Line Leak Detection
7/17/2024
7/17/2025
Leak Detect - Tank
Non-Discriminating Interstitial Monitoring Sensors With Monitor
7/17/2024
7/17/2025
Overfill Prev Device
Overfill Alarm
7/17/2024
7/17/2027
Overfill Prev Device
Overfill Drop Tube Valve
7/17/2024
7/17/2027
Piping
Flexible Double Wall A.P.T. Poly Tech XP 1500
N/A
N/A
Piping
Single Wall STP/Tanktop Sump
3/29/2024
3/29/2027
Leak Detect - Piping
Sump Sensor with positive shutdown
7/17/2024
7/17/2025
Spill Contain Device
Double Wall Spill Bucket
3/29/2024
3/29/2027
Tank
Fiberglass Double Wall KBK Industries
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Piping
Flexible Double Wall A.P.T. Poly Tech XP 1500
Precision Test (Piping)
Pass
7/17/2024
Tank
Fiberglass Double Wall KBK Industries
Precision Test (Tank)
Pass
7/17/2024
Tank Number 2
Capacity:
6000
Petroleum Use:
Product:
Gasoline - Premium
CERCLA Substance:
Status:
Currently in use
CAS Code:
Regulated Status:
Federal
Removed Date:
OSFM
First Notify Date:
3/4/2024
Abandoned Material:
Current Age:
1
Abandoned Date:
Install Date:
10/5/2023
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Flexible Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Fiberglass Non-Corrosive
N/A
N/A
Leak Detect - Piping
Electronic Pressurized Line Leak Detection
7/17/2024
7/17/2025
Leak Detect - Tank
Non-Discriminating Interstitial Monitoring Sensors With Monitor
7/17/2024
7/17/2025
Overfill Prev Device
Overfill Alarm
7/17/2024
7/17/2027
Overfill Prev Device
Overfill Drop Tube Valve
7/17/2024
7/17/2027
Piping
Flexible Double Wall A.P.T. Poly Tech XP 1500
N/A
N/A
Piping
Single Wall STP/Tanktop Sump
3/29/2024
3/29/2027
Leak Detect - Piping
Sump Sensor with positive shutdown
7/17/2024
7/17/2025
Spill Contain Device
Double Wall Spill Bucket
3/29/2024
3/29/2027
Tank
Fiberglass Double Wall KBK Industries
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Piping
Flexible Double Wall A.P.T. Poly Tech XP 1500
Precision Test (Piping)
Pass
7/17/2024
Tank
Fiberglass Double Wall KBK Industries
Precision Test (Tank)
Pass
7/17/2024
Tank Number 3
Capacity:
14000
Petroleum Use:
None
Product:
Diesel Fuel
CERCLA Substance:
Status:
Currently in use
CAS Code:
Regulated Status:
Federal
Removed Date:
OSFM
First Notify Date:
3/4/2024
Abandoned Material:
Current Age:
1
Abandoned Date:
Install Date:
10/5/2023
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Flexible Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Fiberglass Non-Corrosive
N/A
N/A
Leak Detect - Piping
Electronic Pressurized Line Leak Detection
7/17/2024
7/17/2025
Leak Detect - Tank
Non-Discriminating Interstitial Monitoring Sensors With Monitor
7/17/2024
7/17/2025
Overfill Prev Device
Overfill Alarm
7/17/2024
7/17/2027
Overfill Prev Device
Overfill Drop Tube Valve
7/17/2024
7/17/2027
Piping
Flexible Double Wall A.P.T. Poly Tech XP 1500
N/A
N/A
Piping
Single Wall STP/Tanktop Sump
3/29/2024
3/29/2027
Leak Detect - Piping
Sump Sensor with positive shutdown
7/17/2024
7/17/2025
Spill Contain Device
Double Wall Spill Bucket
3/29/2024
3/29/2027
Tank
Fiberglass Double Wall KBK Industries
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Piping
Flexible Double Wall A.P.T. Poly Tech XP 1500
Precision Test (Piping)
Pass
7/17/2024
Tank
Fiberglass Double Wall KBK Industries
Precision Test (Tank)
Pass
7/17/2024
Dispenser Information
Name\ID 1/2
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
3/29/2024
3/29/2027
Leak Detect - Piping
Sump Sensor with positive shutdown
7/17/2024
7/17/2025
Name\ID 11/12
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
3/29/2024
3/29/2027
Leak Detect - Piping
Sump Sensor with positive shutdown
7/17/2024
7/17/2025
Name\ID 13/14
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
3/29/2024
3/29/2027
Leak Detect - Piping
Sump Sensor with positive shutdown
7/17/2024
7/17/2025
Name\ID 15/16
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
3/29/2024
3/29/2027
Leak Detect - Piping
Sump Sensor with positive shutdown
7/17/2024
7/17/2025
Name\ID 17M/18S
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
3/29/2024
3/29/2027
Leak Detect - Piping
Sump Sensor with positive shutdown
7/17/2024
7/17/2025
Name\ID 17S
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
3/29/2024
3/29/2027
Leak Detect - Piping
Sump Sensor with positive shutdown
7/17/2024
7/17/2025
Name\ID 18M
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
3/29/2024
3/29/2027
Leak Detect - Piping
Sump Sensor with positive shutdown
7/17/2024
7/17/2025
Name\ID 3/4
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
3/29/2024
3/29/2027
Leak Detect - Piping
Sump Sensor with positive shutdown
7/17/2024
7/17/2025
Name\ID 5/6
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
3/29/2024
3/29/2027
Leak Detect - Piping
Sump Sensor with positive shutdown
7/17/2024
7/17/2025
Name\ID 7/8
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
3/29/2024
3/29/2027
Leak Detect - Piping
Sump Sensor with positive shutdown
7/17/2024
7/17/2025
Name\ID 9/10
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
3/29/2024
3/29/2027
Leak Detect - Piping
Sump Sensor with positive shutdown
7/17/2024
7/17/2025
MFD
Motorfuel Dispensing Forms
Facility Number
Name
City
Received Date
Letter
2047650
Speed Trek
New Lenox
07/31/2024
Letter
Form
2047650
Speed Trek
New Lenox
07/25/2024
Letter
Form
2047650
Speed Trek
New Lenox
09/21/2023
Letter
Form