Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2047518
Status: Active
Facility Name: QuikTrip #7195
Address: 415 N Swift Road
Addison, IL 60101
County: Du Page
Property Parcel: 02-24-400-041
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Y002434
Green Tag Issue Date: 11/9/2023
Green Tag Expiration Date: 12/31/2025

Owner Details

Owner Name: QuikTrip Corporation
Owner Address: 4705 South 129th East Ave.
Tulsa, OK 74134
Owner Status: Current Owner
Purchase Date: 5/14/2021
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 4/29/2025

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 11/9/2023 12/31/2025

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0034559 QuikTrip Corporation Current Owner 5/14/2021

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 20000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 2/6/2023 Abandoned Material:
Current Age: 2 Abandoned Date:
Install Date: 12/7/2022 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 10/27/2024 10/27/2025
Leak Detect - Piping Siphon Bar N/A N/A
Leak Detect - Tank Hydrostatic Reservoir Interstitial Monitoring Sensors with monitor 10/27/2024 10/27/2025
Overfill Prev Device Overfill Alarm 11/6/2023 11/6/2026
Overfill Prev Device Overfill Drop Tube Valve 11/6/2023 11/6/2026
Piping Flexible Double Wall Franklin Fueling Systems UPP N/A N/A
Piping Single Wall STP/Tanktop Sump 11/6/2023 11/6/2026
Leak Detect - Piping Sump Sensor with positive shutdown 10/27/2024 10/27/2025
Piping Single Wall Transition Sump 11/6/2023 11/6/2026
Leak Detect - Piping Sump Sensor with positive shutdown 10/27/2024 10/27/2025
Piping Single Wall Transition Sump 11/6/2023 11/6/2026
Leak Detect - Piping Sump Sensor with positive shutdown 10/27/2024 10/27/2025
Spill Contain Device Double Wall Spill Bucket 11/6/2023 11/6/2026
Tank Fiberglass Brine Filled Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Leak Detect - Piping Siphon Bar Functional Pass 10/27/2024
Piping Flexible Double Wall Franklin Fueling Systems UPP Precision Test (Piping) Pass 11/6/2023
Tank Fiberglass Brine Filled Double Wall XERXES Precision Test (Tank) Pass 11/6/2023



Tank Number 2

Capacity: 20000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 2/6/2023 Abandoned Material:
Current Age: 2 Abandoned Date:
Install Date: 12/7/2022 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 10/27/2024 10/27/2025
Leak Detect - Piping Siphon Bar N/A N/A
Leak Detect - Tank Hydrostatic Reservoir Interstitial Monitoring Sensors with monitor 10/27/2024 10/27/2025
Overfill Prev Device Overfill Alarm 11/6/2023 11/6/2026
Overfill Prev Device Overfill Drop Tube Valve 11/6/2023 11/6/2026
Piping Flexible Double Wall Franklin Fueling Systems UPP N/A N/A
Piping Single Wall STP/Tanktop Sump 11/6/2023 11/6/2026
Leak Detect - Piping Sump Sensor with positive shutdown 10/27/2024 10/27/2025
Piping Single Wall Transition Sump 11/6/2023 11/6/2026
Leak Detect - Piping Sump Sensor with positive shutdown 10/27/2024 10/27/2025
Piping Single Wall Transition Sump 11/6/2023 11/6/2026
Leak Detect - Piping Sump Sensor with positive shutdown 10/27/2024 10/27/2025
Spill Contain Device Double Wall Spill Bucket 11/6/2023 11/6/2026
Tank Fiberglass Brine Filled Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Leak Detect - Piping Siphon Bar Functional Pass 10/27/2024
Piping Flexible Double Wall Franklin Fueling Systems UPP Precision Test (Piping) Pass 11/6/2023
Tank Fiberglass Brine Filled Double Wall XERXES Precision Test (Tank) Pass 11/6/2023



Tank Number 3

Capacity: 20000 Petroleum Use:
Product: E15 CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 2/6/2023 Abandoned Material:
Current Age: 2 Abandoned Date:
Install Date: 12/7/2022 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 10/27/2024 10/27/2025
Leak Detect - Tank Hydrostatic Reservoir Interstitial Monitoring Sensors with monitor 10/27/2024 10/27/2025
Overfill Prev Device Overfill Alarm 11/6/2023 11/6/2026
Overfill Prev Device Overfill Drop Tube Valve 11/6/2023 11/6/2026
Piping Flexible Double Wall Franklin Fueling Systems UPP N/A N/A
Piping Single Wall STP/Tanktop Sump 11/6/2023 11/6/2026
Leak Detect - Piping Sump Sensor with positive shutdown 10/27/2024 10/27/2025
Piping Single Wall Transition Sump 11/6/2023 11/6/2026
Leak Detect - Piping Sump Sensor with positive shutdown 10/27/2024 10/27/2025
Piping Single Wall Transition Sump 11/6/2023 11/6/2026
Leak Detect - Piping Sump Sensor with positive shutdown 10/27/2024 10/27/2025
Spill Contain Device Double Wall Spill Bucket 11/6/2023 11/6/2026
Tank Fiberglass Brine Filled Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Franklin Fueling Systems UPP Precision Test (Piping) Pass 11/6/2023
Tank Fiberglass Brine Filled Double Wall XERXES Precision Test (Tank) Pass 11/6/2023



Tank Number 4

Capacity: 20000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 2/6/2023 Abandoned Material:
Current Age: 2 Abandoned Date:
Install Date: 12/7/2022 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 10/27/2024 10/27/2025
Leak Detect - Tank Hydrostatic Reservoir Interstitial Monitoring Sensors with monitor 10/27/2024 10/27/2025
Overfill Prev Device Overfill Alarm 11/6/2023 11/6/2026
Overfill Prev Device Overfill Drop Tube Valve 11/6/2023 11/6/2026
Piping Flexible Double Wall Franklin Fueling Systems UPP N/A N/A
Piping Single Wall STP/Tanktop Sump 11/6/2023 11/6/2026
Leak Detect - Piping Sump Sensor with positive shutdown 10/27/2024 10/27/2025
Piping Single Wall Transition Sump 11/6/2023 11/6/2026
Leak Detect - Piping Sump Sensor with positive shutdown 10/27/2024 10/27/2025
Piping Single Wall Transition Sump 11/6/2023 11/6/2026
Leak Detect - Piping Sump Sensor with positive shutdown 10/27/2024 10/27/2025
Spill Contain Device Double Wall Spill Bucket 11/6/2023 11/6/2026
Tank Fiberglass Brine Filled Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Franklin Fueling Systems UPP Precision Test (Piping) Pass 11/6/2023
Tank Fiberglass Brine Filled Double Wall XERXES Precision Test (Tank) Pass 11/6/2023



Tank Number 5

Capacity: 18000 Petroleum Use: None
Product: B-99 CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 2/6/2023 Abandoned Material:
Current Age: 2 Abandoned Date:
Install Date: 12/21/2022 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 10/27/2024 10/27/2025
Leak Detect - Tank Hydrostatic Reservoir Interstitial Monitoring Sensors with monitor 10/27/2024 10/27/2025
Overfill Prev Device Overfill Alarm 11/6/2023 11/6/2026
Overfill Prev Device Overfill Drop Tube Valve 11/6/2023 11/6/2026
Piping Blending Sump 11/6/2023 11/6/2026
Leak Detect - Piping Sump Sensor with positive shutdown 10/27/2024 10/27/2025
Piping Blending Sump 11/6/2023 11/6/2026
Leak Detect - Piping Sump Sensor with positive shutdown 10/27/2024 10/27/2025
Piping Blending Sump 11/6/2023 11/6/2026
Leak Detect - Piping Sump Sensor with positive shutdown 10/27/2024 10/27/2025
Piping Blending Sump 11/6/2023 11/6/2026
Leak Detect - Piping Sump Sensor with positive shutdown 10/27/2024 10/27/2025
Piping Flexible Double Wall Franklin Fueling Systems UPP N/A N/A
Piping Single Wall STP/Tanktop Sump 11/6/2023 11/6/2026
Leak Detect - Piping Sump Sensor with positive shutdown 10/27/2024 10/27/2025
Spill Contain Device Double Wall Spill Bucket 11/6/2023 11/6/2026
Tank Fiberglass Brine Filled Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Franklin Fueling Systems UPP Precision Test (Piping) Pass 11/6/2023
Tank Fiberglass Brine Filled Double Wall XERXES Precision Test (Tank) Pass 11/6/2023



Tank Number 6

Capacity: 30000 Petroleum Use: None
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 2/6/2023 Abandoned Material:
Current Age: 2 Abandoned Date:
Install Date: 12/21/2022 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 10/27/2024 10/27/2025
Leak Detect - Piping Siphon Bar N/A N/A
Leak Detect - Tank Hydrostatic Reservoir Interstitial Monitoring Sensors with monitor 10/27/2024 10/27/2025
Overfill Prev Device Overfill Alarm 11/6/2023 11/6/2026
Overfill Prev Device Overfill Drop Tube Valve 11/6/2023 11/6/2026
Piping Blending Sump 11/6/2023 11/6/2026
Leak Detect - Piping Sump Sensor with positive shutdown 10/27/2024 10/27/2025
Piping Blending Sump 11/6/2023 11/6/2026
Leak Detect - Piping Sump Sensor with positive shutdown 10/27/2024 10/27/2025
Piping Flexible Double Wall Franklin Fueling Systems UPP N/A N/A
Piping Single Wall STP/Tanktop Sump 11/6/2023 11/6/2026
Leak Detect - Piping Sump Sensor with positive shutdown 10/27/2024 10/27/2025
Piping Single Wall Transition Sump 11/6/2023 11/6/2026
Leak Detect - Piping Sump Sensor with positive shutdown 10/27/2024 10/27/2025
Piping Single Wall Transition Sump 11/6/2023 11/6/2026
Leak Detect - Piping Sump Sensor with positive shutdown 10/27/2024 10/27/2025
Piping Single Wall Transition Sump 11/6/2023 11/6/2026
Leak Detect - Piping Sump Sensor with positive shutdown 10/27/2024 10/27/2025
Spill Contain Device Double Wall Spill Bucket 11/6/2023 11/6/2026
Tank Fiberglass Brine Filled Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Leak Detect - Piping Siphon Bar Functional Pass 10/27/2024
Piping Flexible Double Wall Franklin Fueling Systems UPP Precision Test (Piping) Pass 11/6/2023
Tank Fiberglass Brine Filled Double Wall XERXES Precision Test (Tank) Pass 11/6/2023



Tank Number 7

Capacity: 30000 Petroleum Use: None
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 2/6/2023 Abandoned Material:
Current Age: 2 Abandoned Date:
Install Date: 12/21/2022 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 10/27/2024 10/27/2025
Leak Detect - Piping Siphon Bar N/A N/A
Leak Detect - Tank Hydrostatic Reservoir Interstitial Monitoring Sensors with monitor 10/27/2024 10/27/2025
Overfill Prev Device Overfill Alarm 11/6/2023 11/6/2026
Overfill Prev Device Overfill Drop Tube Valve 11/6/2023 11/6/2026
Piping Blending Sump 11/6/2023 11/6/2026
Leak Detect - Piping Sump Sensor with positive shutdown 10/27/2024 10/27/2025
Piping Flexible Double Wall Franklin Fueling Systems UPP N/A N/A
Piping Single Wall Transition Sump 11/6/2023 11/6/2026
Leak Detect - Piping Sump Sensor with positive shutdown 10/27/2024 10/27/2025
Spill Contain Device Double Wall Spill Bucket 11/6/2023 11/6/2026
Tank Fiberglass Brine Filled Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Leak Detect - Piping Siphon Bar Functional Pass 10/27/2024
Piping Flexible Double Wall Franklin Fueling Systems UPP Precision Test (Piping) Pass 11/6/2023
Tank Fiberglass Brine Filled Double Wall XERXES Precision Test (Tank) Pass 11/6/2023



Tank Number 8

Capacity: 30000 Petroleum Use: None
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 2/6/2023 Abandoned Material:
Current Age: 2 Abandoned Date:
Install Date: 12/29/2022 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 10/27/2024 10/27/2025
Leak Detect - Piping Siphon Bar N/A N/A
Leak Detect - Tank Hydrostatic Reservoir Interstitial Monitoring Sensors with monitor 10/27/2024 10/27/2025
Overfill Prev Device Overfill Alarm 11/6/2023 11/6/2026
Overfill Prev Device Overfill Drop Tube Valve 11/6/2023 11/6/2026
Piping Blending Sump 11/6/2023 11/6/2026
Leak Detect - Piping Sump Sensor with positive shutdown 10/27/2024 10/27/2025
Piping Flexible Double Wall Franklin Fueling Systems UPP N/A N/A
Piping Single Wall STP/Tanktop Sump 11/6/2023 11/6/2026
Leak Detect - Piping Sump Sensor with positive shutdown 10/27/2024 10/27/2025
Spill Contain Device Double Wall Spill Bucket 11/6/2023 11/6/2026
Tank Fiberglass Brine Filled Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Leak Detect - Piping Siphon Bar Functional Pass 10/27/2024
Piping Flexible Double Wall Franklin Fueling Systems UPP Precision Test (Piping) Pass 11/6/2023
Tank Fiberglass Brine Filled Double Wall XERXES Precision Test (Tank) Pass 11/6/2023

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 11/6/2023 11/6/2026
Leak Detect - Piping Sump Sensor with positive shutdown 10/27/2024 10/27/2025



Name\ID 11/12

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 11/6/2023 11/6/2026
Leak Detect - Piping Sump Sensor with positive shutdown 10/27/2024 10/27/2025



Name\ID 13/14

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 11/6/2023 11/6/2026
Leak Detect - Piping Sump Sensor with positive shutdown 10/27/2024 10/27/2025



Name\ID 15/16

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 11/6/2023 11/6/2026
Leak Detect - Piping Sump Sensor with positive shutdown 10/27/2024 10/27/2025



Name\ID 17/18

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 11/6/2023 11/6/2026
Leak Detect - Piping Sump Sensor with positive shutdown 10/27/2024 10/27/2025



Name\ID 19/20

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 11/6/2023 11/6/2026
Leak Detect - Piping Sump Sensor with positive shutdown 10/27/2024 10/27/2025



Name\ID 1D/2D

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 11/6/2023 11/6/2026
Leak Detect - Piping Sump Sensor with positive shutdown 10/27/2024 10/27/2025



Name\ID 2D/3D

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 11/6/2023 11/6/2026
Leak Detect - Piping Sump Sensor with positive shutdown 10/27/2024 10/27/2025



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 11/6/2023 11/6/2026
Leak Detect - Piping Sump Sensor with positive shutdown 10/27/2024 10/27/2025



Name\ID 3D/4D

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 11/6/2023 11/6/2026
Leak Detect - Piping Sump Sensor with positive shutdown 10/27/2024 10/27/2025



Name\ID 4D/5D

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 11/6/2023 11/6/2026
Leak Detect - Piping Sump Sensor with positive shutdown 10/27/2024 10/27/2025



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 11/6/2023 11/6/2026
Leak Detect - Piping Sump Sensor with positive shutdown 10/27/2024 10/27/2025



Name\ID 5D/6D

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 11/6/2023 11/6/2026
Leak Detect - Piping Sump Sensor with positive shutdown 10/27/2024 10/27/2025



Name\ID 6D/7D

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 11/6/2023 11/6/2026
Leak Detect - Piping Sump Sensor with positive shutdown 10/27/2024 10/27/2025



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 11/6/2023 11/6/2026
Leak Detect - Piping Sump Sensor with positive shutdown 10/27/2024 10/27/2025



Name\ID 9/10

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 11/6/2023 11/6/2026
Leak Detect - Piping Sump Sensor with positive shutdown 10/27/2024 10/27/2025

MFD Motorfuel Dispensing Forms

Facility Number Name City Received Date Letter
2047518 QuikTrip #7195 Addison 09/27/2023 Letter Form