Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2047017
Status: Active
Facility Name: 7-Eleven Store #38585
Address: 560 W Grenshaw Chicago, IL 60607
County: Cook
Property Parcel: 17-16-328-026-000; 17-16-328-027-0000
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: BB01886
Green Tag Issue Date: 4/28/2026
Green Tag Expire Date: 12/31/2028
MFD Type: Self Service

Owner Details

Owner Name: Wabash-Van Buren Park One, LLC
Owner Address: 65 E. Harrison Street Chicago, IL 60605
Owner Status: Current Owner
Purchase Date: 1/3/2020
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 12/8/2026

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0041395 Wabash-Van Buren Park One, LLC Current Owner 1/3/2020
U0039361 GW South Loop, LLC Former Owner 6/25/2018

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 20000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 6/25/2020 Abandoned Material:
Current Age: 6 Abandoned Date:
Install Date: 6/18/2020 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 6/24/2026 6/24/2027
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 6/24/2026 6/24/2027
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 8/12/2026 8/12/2027
Overfill Prev Device Overfill Drop Tube Valve 6/24/2026 6/24/2029
Piping Polyethylene Chase Not applicable Not applicable
Piping Flexible Double Wall OPW Flexworks Not applicable Not applicable
Piping Fiberglass Single Wall Piping Not applicable Not applicable
Piping Single Wall STP/Tanktop Sump 5/28/2026 5/28/2029
Leak Detect - Piping Sump Sensor with positive shutdown 5/28/2026 5/28/2029
Spill Contain Device Double Wall Spill Bucket 6/24/2026 6/24/2029
Tank Fiberglass Double Wall XERXES Not applicable Not applicable

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test (Piping) Pass 6/24/2026
Piping Flexible Double Wall OPW Flexworks Precision Test (Piping) Pass 6/24/2026
Piping Polyethylene Chase Precision Test (Piping) Pass 6/24/2026
Tank Fiberglass Double Wall XERXES Precision Test (Tank) Pass 10/30/2020



Tank Number 2

Capacity: 8000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 6/25/2020 Abandoned Material:
Current Age: 6 Abandoned Date:
Install Date: 6/18/2020 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 6/24/2026 6/24/2027
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 6/24/2026 6/24/2027
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 6/24/2026 6/24/2027
Overfill Prev Device Overfill Drop Tube Valve 6/24/2026 6/24/2029
Piping Polyethylene Chase Not applicable Not applicable
Piping Flexible Double Wall OPW Flexworks Not applicable Not applicable
Piping Fiberglass Single Wall Piping Not applicable Not applicable
Piping Single Wall STP/Tanktop Sump 5/28/2026 5/28/2029
Leak Detect - Piping Sump Sensor with positive shutdown 5/28/2026 5/28/2029
Spill Contain Device Double Wall Spill Bucket 6/24/2026 6/24/2029
Tank Fiberglass Double Wall XERXES Not applicable Not applicable

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test (Piping) Pass 6/24/2026
Piping Flexible Double Wall OPW Flexworks Precision Test (Piping) Pass 6/24/2026
Piping Polyethylene Chase Precision Test (Piping) Pass 6/24/2026
Tank Fiberglass Double Wall XERXES Precision Test (Tank) Pass 10/30/2020



Tank Number 3

Capacity: 12000 Petroleum Use: None
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 6/25/2020 Abandoned Material:
Current Age: 6 Abandoned Date:
Install Date: 6/18/2020 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 6/24/2026 6/24/2027
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 6/24/2026 6/24/2027
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 6/24/2026 6/24/2027
Overfill Prev Device Overfill Drop Tube Valve 6/24/2026 6/24/2029
Piping Polyethylene Chase Not applicable Not applicable
Piping Flexible Double Wall OPW Flexworks Not applicable Not applicable
Piping Fiberglass Single Wall Piping Not applicable Not applicable
Piping Single Wall STP/Tanktop Sump 5/28/2026 5/28/2029
Leak Detect - Piping Sump Sensor with positive shutdown 5/28/2026 5/28/2029
Spill Contain Device Double Wall Spill Bucket 6/24/2026 6/24/2029
Tank Fiberglass Double Wall XERXES Not applicable Not applicable

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test (Piping) Pass 6/24/2026
Piping Flexible Double Wall OPW Flexworks Precision Test (Piping) Pass 6/24/2026
Piping Polyethylene Chase Precision Test (Piping) Pass 6/24/2026
Tank Fiberglass Double Wall XERXES Precision Test (Tank) Pass 10/30/2020

Failed test = the latest test has failed.

Not applicable = a test does not apply to this equipment type or configuration.

No passing test found = a passing test is expected but was not found from the source data.


Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 5/28/2026 5/28/2029
Leak Detect - Piping Sump Sensor with positive shutdown 6/24/2026 6/24/2027



Name\ID 11/12

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 5/28/2026 5/28/2029
Leak Detect - Piping Sump Sensor with positive shutdown 6/24/2026 6/24/2027



Name\ID 13/14

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 5/28/2026 5/28/2029
Leak Detect - Piping Sump Sensor with positive shutdown 6/24/2026 6/24/2027



Name\ID 15/16

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 5/28/2026 5/28/2029
Leak Detect - Piping Sump Sensor with positive shutdown 6/24/2026 6/24/2027



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 5/28/2026 5/28/2029
Leak Detect - Piping Sump Sensor with positive shutdown 6/24/2026 6/24/2027



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 5/28/2026 5/28/2029
Leak Detect - Piping Sump Sensor with positive shutdown 6/24/2026 6/24/2027



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 5/28/2026 5/28/2029
Leak Detect - Piping Sump Sensor with positive shutdown 6/24/2026 6/24/2027



Name\ID 9/10

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 5/28/2026 5/28/2029
Leak Detect - Piping Sump Sensor with positive shutdown 6/24/2026 6/24/2027

Failed test = the latest test has failed.

Not applicable = a test does not apply to this equipment type or configuration.

No passing test found = a passing test is expected but was not found from the source data.


MFD Motorfuel Dispensing Forms

Facility Number Name City Received Date Letter
2047017 7-Eleven Store #38585 Chicago 11/12/2020 Letter Form