Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2046799
Status: Active
Facility Name: Skystar of IL, LLC
Address: 7050 S. Archer Rd. Bedford Park, IL 60458
County: Cook
Property Parcel:
Facility Type: Trucking Company
Owner Type: Private
Green Tag Decal: AA03483
Green Tag Issue Date: 3/19/2025
Green Tag Expire Date: 12/31/2027
MFD Type: Fleet

Owner Details

Owner Name: Skystar of IL, LLC
Owner Address: 7050 S. Archer Rd. Bedford Park, IL 60458
Owner Status: Current Owner
Purchase Date: 1/1/2019
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 3/19/2026

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0039474 Skystar of IL, LLC Current Owner 1/1/2019

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 6000 Petroleum Use: None
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 5/22/2019 Abandoned Material:
Current Age: 7 Abandoned Date:
Install Date: 4/24/2019 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 4/25/2019

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping European with No Test Req Suction Not applicable Not applicable
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS - 4c 4/16/2026 4/16/2027
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 4/16/2026 4/16/2027
Manway At Grade Accessible Manway Accessible at Grade Not applicable Not applicable
Overfill Prev Device Overfill Drop Tube Valve 4/18/2025 4/18/2028
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Not applicable Not applicable
Piping Single Wall STP/Tanktop Sump Not applicable Not applicable
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required Not applicable Not applicable
Spill Contain Device Single Wall Spill Bucket 4/18/2025 4/18/2028
Tank Fiberglass Double Wall XERXES Not applicable Not applicable
Vent, Riser, Fill Piping Steel risers Not applicable Not applicable

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 6/11/2021
Tank Fiberglass Double Wall XERXES Precision Test (Tank) Pass 5/17/2019



Tank Number 2

Capacity: 4000 Petroleum Use: None
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 5/22/2019 Abandoned Material:
Current Age: 7 Abandoned Date:
Install Date: 4/24/2019 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 4/25/2019

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping European with No Test Req Suction Not applicable Not applicable
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS - 4c 4/16/2026 4/16/2027
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 4/16/2026 4/16/2027
Manway At Grade Accessible Manway Accessible at Grade Not applicable Not applicable
Overfill Prev Device Overfill Drop Tube Valve 4/18/2025 4/18/2028
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Not applicable Not applicable
Piping Single Wall STP/Tanktop Sump Not applicable Not applicable
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required Not applicable Not applicable
Spill Contain Device Single Wall Spill Bucket 4/18/2025 4/18/2028
Tank Fiberglass Double Wall XERXES Not applicable Not applicable
Vent, Riser, Fill Piping Steel risers Not applicable Not applicable

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 6/11/2021
Tank Fiberglass Double Wall XERXES Precision Test (Tank) Pass 5/17/2019

Failed test = the latest test has failed.

Not applicable = a test does not apply to this equipment type or configuration.

No passing test found = a passing test is expected but was not found from the source data.


Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump Not applicable Not applicable
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required Not applicable Not applicable

Failed test = the latest test has failed.

Not applicable = a test does not apply to this equipment type or configuration.

No passing test found = a passing test is expected but was not found from the source data.


MFD Motorfuel Dispensing Forms

Facility Number Name City Received Date Letter
2046799 Skystar of IL, LLC Bedford Park 04/25/2019 Letter Form