Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2046697
Status: Active
Facility Name: Speedway #7764
Address: 1031 E Main Street East Dundee, IL 60118
County: Kane
Property Parcel: 03-25-126-005
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: AA001211
Green Tag Issue Date: 3/26/2025
Green Tag Expire Date: 12/31/2027
MFD Type: Self Service

Owner Details

Owner Name: Speedway, LLC
Owner Address: P.O. Box 1500 Springfield, OH 45501
Owner Status: Current Owner
Purchase Date: 6/21/2017
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 12/8/2026

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0026552 Speedway, LLC Current Owner 6/21/2017

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 6000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 6/21/2021 Abandoned Material:
Current Age: 5 Abandoned Date:
Install Date: 9/25/2018 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 6/2/2021

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Electronic Pressurized Line Leak Detection 6/4/2026 6/4/2027
Leak Detect - Tank Automatic Tank Gauging Incon TS 550 EVO 6/4/2026 6/4/2027
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 6/4/2026 6/4/2027
Overfill Prev Device Overfill Alarm 6/11/2024 6/11/2027
Overfill Prev Device Overfill Drop Tube Valve 6/11/2024 6/11/2027
Piping Flexible Double Wall Franklin Fueling Systems UPP Not applicable Not applicable
Piping Single Wall STP/Tanktop Sump 6/1/2024 6/1/2027
Leak Detect - Piping Sump Sensor with positive shutdown 6/1/2024 6/1/2027
Spill Contain Device Single Wall Spill Bucket 6/1/2024 6/1/2027
Tank Fiberglass Double Wall Containment Solutions Not applicable Not applicable

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Franklin Fueling Systems UPP Precision Test (Piping) Pass 6/14/2021
Tank Fiberglass Double Wall Containment Solutions Precision Test (Tank) Pass 6/14/2021



Tank Number 2

Capacity: 6000 Petroleum Use:
Product: E85 CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 6/21/2021 Abandoned Material:
Current Age: 5 Abandoned Date:
Install Date: 9/25/2018 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 6/2/2021

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Electronic Pressurized Line Leak Detection 6/4/2026 6/4/2027
Leak Detect - Tank Automatic Tank Gauging Incon TS 550 EVO 6/4/2026 6/4/2027
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 6/4/2026 6/4/2027
Overfill Prev Device Overfill Alarm 6/11/2024 6/11/2027
Overfill Prev Device Overfill Drop Tube Valve 6/11/2024 6/11/2027
Piping Flexible Double Wall Franklin Fueling Systems UPP Not applicable Not applicable
Piping Single Wall STP/Tanktop Sump 6/1/2024 6/1/2027
Leak Detect - Piping Sump Sensor with positive shutdown 6/1/2024 6/1/2027
Spill Contain Device Single Wall Spill Bucket 6/1/2024 6/1/2027
Tank Fiberglass Double Wall Containment Solutions Not applicable Not applicable

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Franklin Fueling Systems UPP Precision Test (Piping) Pass 6/14/2021
Tank Fiberglass Double Wall Containment Solutions Precision Test (Tank) Pass 6/14/2021



Tank Number 3

Capacity: 12000 Petroleum Use: None
Product: B-11 CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 6/21/2021 Abandoned Material:
Current Age: 5 Abandoned Date:
Install Date: 9/25/2018 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 6/2/2021

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Electronic Pressurized Line Leak Detection 6/4/2026 6/4/2027
Leak Detect - Tank Automatic Tank Gauging Incon TS 550 EVO 6/4/2026 6/4/2027
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 6/4/2026 6/4/2027
Overfill Prev Device Overfill Alarm 6/11/2024 6/11/2027
Overfill Prev Device Overfill Drop Tube Valve 6/11/2024 6/11/2027
Piping Flexible Double Wall Franklin Fueling Systems UPP Not applicable Not applicable
Piping Single Wall STP/Tanktop Sump 6/1/2024 6/1/2027
Leak Detect - Piping Sump Sensor with positive shutdown 6/1/2024 6/1/2027
Spill Contain Device Single Wall Spill Bucket 6/1/2024 6/1/2027
Tank Fiberglass Double Wall Containment Solutions Not applicable Not applicable

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Franklin Fueling Systems UPP Precision Test (Piping) Pass 6/14/2021
Tank Fiberglass Double Wall Containment Solutions Precision Test (Tank) Pass 6/14/2021



Tank Number 4

Capacity: 20000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 6/21/2021 Abandoned Material:
Current Age: 5 Abandoned Date:
Install Date: 9/25/2018 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 6/2/2021

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Electronic Pressurized Line Leak Detection 6/4/2026 6/4/2027
Leak Detect - Tank Automatic Tank Gauging Incon TS 550 EVO 6/4/2026 6/4/2027
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 6/4/2026 6/4/2027
Overfill Prev Device Overfill Alarm 6/11/2024 6/11/2027
Overfill Prev Device Overfill Drop Tube Valve 6/11/2024 6/11/2027
Overfill Prev Device Overfill Drop Tube Valve 6/11/2024 6/11/2027
Piping Flexible Double Wall Franklin Fueling Systems UPP Not applicable Not applicable
Piping Single Wall STP/Tanktop Sump 6/1/2024 6/1/2027
Leak Detect - Piping Sump Sensor with positive shutdown 6/1/2024 6/1/2027
Spill Contain Device Single Wall Spill Bucket 6/1/2024 6/1/2027
Spill Contain Device Single Wall Spill Bucket 6/1/2024 6/1/2027
Tank Fiberglass Double Wall Containment Solutions Not applicable Not applicable

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Franklin Fueling Systems UPP Precision Test (Piping) Pass 6/14/2021
Tank Fiberglass Double Wall Containment Solutions Precision Test (Tank) Pass 6/14/2021



Tank Number 5

Capacity: 20000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 6/21/2021 Abandoned Material:
Current Age: 5 Abandoned Date:
Install Date: 9/25/2018 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 6/2/2021

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Mechanical Other Non-vented check valve Not applicable Not applicable
Leak Detect - Tank Automatic Tank Gauging Incon TS 550 EVO 6/4/2026 6/4/2027
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 6/4/2026 6/4/2027
Overfill Prev Device Overfill Alarm 6/11/2024 6/11/2027
Overfill Prev Device Overfill Drop Tube Valve 6/11/2024 6/11/2027
Overfill Prev Device Overfill Drop Tube Valve 6/11/2024 6/11/2027
Piping Flexible Double Wall Franklin Fueling Systems UPP Not applicable Not applicable
Piping Single Wall STP/Tanktop Sump 6/1/2024 6/1/2027
Leak Detect - Piping Sump Sensor with positive shutdown 6/1/2024 6/1/2027
Spill Contain Device Single Wall Spill Bucket 6/1/2024 6/1/2027
Spill Contain Device Single Wall Spill Bucket 6/1/2024 6/1/2027
Tank Fiberglass Double Wall Containment Solutions Not applicable Not applicable

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Franklin Fueling Systems UPP Precision Test (Piping) Pass 6/14/2021
Tank Fiberglass Double Wall Containment Solutions Precision Test (Tank) Pass 6/14/2021



Tank Number 6

Capacity: 20000 Petroleum Use: None
Product: B-11 CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 6/21/2021 Abandoned Material:
Current Age: 5 Abandoned Date:
Install Date: 10/2/2018 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 6/2/2021

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Electronic Pressurized Line Leak Detection 6/4/2026 6/4/2027
Leak Detect - Tank Automatic Tank Gauging Incon TS 550 EVO 6/4/2026 6/4/2027
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 6/4/2026 6/4/2027
Overfill Prev Device Overfill Alarm 6/11/2024 6/11/2027
Overfill Prev Device Overfill Drop Tube Valve 6/11/2024 6/11/2027
Overfill Prev Device Overfill Drop Tube Valve 6/11/2024 6/11/2027
Piping Flexible Double Wall Franklin Fueling Systems UPP Not applicable Not applicable
Piping Single Wall STP/Tanktop Sump 6/1/2024 6/1/2027
Leak Detect - Piping Sump Sensor with positive shutdown 6/1/2024 6/1/2027
Spill Contain Device Single Wall Spill Bucket 6/1/2024 6/1/2027
Spill Contain Device Single Wall Spill Bucket 6/1/2024 6/1/2027
Tank Fiberglass Double Wall Containment Solutions Not applicable Not applicable

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Franklin Fueling Systems UPP Precision Test (Piping) Pass 7/9/2024
Tank Fiberglass Double Wall Containment Solutions Precision Test (Tank) Pass 6/14/2021



Tank Number 7

Capacity: 20000 Petroleum Use: None
Product: B-11 CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 6/21/2021 Abandoned Material:
Current Age: 5 Abandoned Date:
Install Date: 10/2/2018 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 6/2/2021

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Mechanical Other Non-vented check valve Not applicable Not applicable
Leak Detect - Tank Automatic Tank Gauging Incon TS 550 EVO 6/4/2026 6/4/2027
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 6/4/2026 6/4/2027
Overfill Prev Device Overfill Alarm 6/11/2024 6/11/2027
Overfill Prev Device Overfill Drop Tube Valve 6/11/2024 6/11/2027
Overfill Prev Device Overfill Drop Tube Valve 6/11/2024 6/11/2027
Piping Flexible Double Wall Franklin Fueling Systems UPP Not applicable Not applicable
Piping Single Wall STP/Tanktop Sump 6/1/2024 6/1/2027
Leak Detect - Piping Sump Sensor with positive shutdown 6/1/2024 6/1/2027
Spill Contain Device Single Wall Spill Bucket 6/1/2024 6/1/2027
Spill Contain Device Single Wall Spill Bucket 6/1/2024 6/1/2027
Tank Fiberglass Double Wall Containment Solutions Not applicable Not applicable

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Franklin Fueling Systems UPP Precision Test (Piping) Pass 7/9/2024
Tank Fiberglass Double Wall Containment Solutions Precision Test (Tank) Pass 6/14/2021



Tank Number 8

Capacity: 10000 Petroleum Use: None
Product: Diesel Exhaust Fluid (Non-Regulated) CERCLA Substance:
Status: Unknown CAS Code:
Regulated Status: Non-Regulated Removed Date:
OSFM First Notify Date: 6/21/2021 Abandoned Material:
Current Age: 5 Abandoned Date:
Install Date: 10/2/2018 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 6/2/2021

Equipment Information

No Equipment Listed


Additional Tests

No Tests Listed


Failed test = the latest test has failed.

Not applicable = a test does not apply to this equipment type or configuration.

No passing test found = a passing test is expected but was not found from the source data.


Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/1/2024 6/1/2027
Leak Detect - Piping Sump Sensor with positive shutdown 6/4/2026 6/4/2027



Name\ID 11/12

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/1/2024 6/1/2027
Leak Detect - Piping Sump Sensor with positive shutdown 6/4/2026 6/4/2027



Name\ID 13/14

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/1/2024 6/1/2027
Leak Detect - Piping Sump Sensor with positive shutdown 6/4/2026 6/4/2027



Name\ID 15/16

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/1/2024 6/1/2027
Leak Detect - Piping Sump Sensor with positive shutdown 6/4/2026 6/4/2027



Name\ID 17/18

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/1/2024 6/1/2027
Leak Detect - Piping Sump Sensor with positive shutdown 6/4/2026 6/4/2027



Name\ID 19/20

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/1/2024 6/1/2027
Leak Detect - Piping Sump Sensor with positive shutdown 6/4/2026 6/4/2027



Name\ID 21M/22S

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/1/2024 6/1/2027
Leak Detect - Piping Sump Sensor with positive shutdown 6/4/2026 6/4/2027



Name\ID 21S

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/1/2024 6/1/2027
Leak Detect - Piping Sump Sensor with positive shutdown 6/4/2026 6/4/2027



Name\ID 22M/23S

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/1/2024 6/1/2027
Leak Detect - Piping Sump Sensor with positive shutdown 6/4/2026 6/4/2027



Name\ID 23M/24S

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/1/2024 6/1/2027
Leak Detect - Piping Sump Sensor with positive shutdown 6/4/2026 6/4/2027



Name\ID 24M

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/1/2024 6/1/2027
Leak Detect - Piping Sump Sensor with positive shutdown 6/4/2026 6/4/2027



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/1/2024 6/1/2027
Leak Detect - Piping Sump Sensor with positive shutdown 6/4/2026 6/4/2027



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/1/2024 6/1/2027
Leak Detect - Piping Sump Sensor with positive shutdown 6/4/2026 6/4/2027



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/1/2024 6/1/2027
Leak Detect - Piping Sump Sensor with positive shutdown 6/4/2026 6/4/2027



Name\ID 9/10

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/1/2024 6/1/2027
Leak Detect - Piping Sump Sensor with positive shutdown 6/4/2026 6/4/2027

Failed test = the latest test has failed.

Not applicable = a test does not apply to this equipment type or configuration.

No passing test found = a passing test is expected but was not found from the source data.


MFD Motorfuel Dispensing Forms

Facility Number Name City Received Date Letter
2046697 Speedway #7764 East Dundee 06/16/2021 Letter Form