Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2046680
Status: Active
Facility Name: Love's Travel Stop #763
Address: 201 Love's Crossing
Hampshire, IL 60140
County: Kane
Property Parcel: 03-01-101-009
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Y001662
Green Tag Issue Date: 3/1/2023
Green Tag Expiration Date: 12/31/2025

Owner Details

Owner Name: Love's Travel Stops & Country Stores, Inc.
Owner Address: 10601 N. Penn
P.O. Box 26210
Oklahoma City, OK 73120
Owner Status: Current Owner
Purchase Date:
Type of Financial Responsibility: Self-Insurance
Financial Responsibility Reporting Due Date: 6/29/2026

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 3/1/2023 12/31/2025

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0030965 Love's Travel Stops & Country Stores, Inc. Current Owner

Permits (Unexpired)

Click for permit history
Permit Number Type Status OSFM Receive Date Issue Date Expiration Date Documents
00196-2025UPG Upgrade Approved / Issued 2/21/2025 2/24/2025 8/26/2025 Documents

Notice of Violations (Current)

NOV Number: E0020251133 (Pending)    Issue Date: 4/29/2025    Expiration Date: 6/28/2025    View NOV Form

Tanks Violation
Facility Annual Emergency Stop Inspection not completed or inspection report not available. - All emergency shutoff switches shall be tested annually to verify they shut down all STPs or dispensers. Perform test, complete form (form is available at www.sfm.illinois.gov) and maintain 2 years on site with other annual testing documentation. NO RESULTS AT FACILITY FOR 2024 OR 2025.
1 Containment support components are cracked, deteriorated or missing. The cover and supporting components that are defective shall be replaced with factory manufactured components. - Section 175.410 Submersible, Under-dispenser, Transition and Other Containment Sumps a) All containment sumps must consist of a factory manufactured containment that is liquid-tight on its sides, bottom and at any penetrations and is compatible with the substance conveyed by the piping. Such containment shall also have a factory manufactured protective cover and supporting components that are properly maintained. If the protective cover or its supporting components are cracked, deteriorated or missing, the cover and supporting components that are defective shall be replaced. SPECIFICALLY THE HANDLE FOR THE RUL STP LID.
Facility Missing copies of Annual Walkthrough Inspection Report. - Annual Walkthrough by a licensed contractor shall be conducted and 2 years documentation maintained on site. NO RESULTS AT FACILITY FOR 2024 OR 2025.
8, 9, 10, 11, 12, 13, 14 Precision tank test required. - Precision tank test is required on tank(s) if you cannot provide 24 months’ worth of tank “NORMAL/OK” from ATG.
1, 2, 3, 4, 5, 6, 8, 9, 10, 11, 12, 13, 14 Required monthly tank leak test records not available. - Maintain one NORMAL report per TANK, per month, from ATG. Must maintain 24 months’ worth. Tanks 8-14 missing March - Dec of 2023 and Jan - June, Sep, & Dec of 2024, also Jan and March of 2025. Tanks 1 - 6 were missing Oct & Nov of 2023, Apr & Nov of 2024, and Jan of 2025.
1, 2, 3, 4, 5, 6 Shear valve inspection report not completed (Required during Annual Walkthrough Inspection). - Provide documentation that annual testing of all shear valves has been conducted and passed. Must maintain 2 years of inspection reports. NO RESULTS AT FACILITY FOR 2024 OR 2025.

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 20000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 5/24/2019 Abandoned Material:
Current Age: 6 Abandoned Date:
Install Date: 8/31/2018 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 2/5/2025 2/5/2026
Leak Detect - Piping Siphon Bar N/A N/A
Leak Detect - Tank Automatic Tank Gauging Incon TS 550 EVO 2/5/2025 2/5/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 2/5/2025 2/5/2026
Manway At Grade Accessible Manway Accessible at Grade N/A N/A
Overfill Prev Device Overfill Alarm 2/24/2025 2/24/2028
Overfill Prev Device Overfill Drop Tube Valve 3/16/2023 3/16/2026
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 3/19/2025 3/19/2028
Leak Detect - Piping Sump Sensor with positive shutdown 2/5/2025 2/5/2026
Spill Contain Device Single Wall Spill Bucket 3/28/2025 3/28/2028
Tank Fiberglass Double Wall ZCL, USA Prezerver N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Leak Detect - Piping Siphon Bar Functional Pass 3/16/2023
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 5/5/2020
Tank Fiberglass Double Wall ZCL, USA Prezerver Precision Test (Tank) Pass 6/4/2019



Tank Number 2

Capacity: 12000 Petroleum Use:
Product: E98 CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 5/24/2019 Abandoned Material:
Current Age: 6 Abandoned Date:
Install Date: 8/31/2018 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 2/5/2025 2/5/2026
Leak Detect - Piping Siphon Bar N/A N/A
Leak Detect - Tank Automatic Tank Gauging Incon TS 550 EVO 2/5/2025 2/5/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 2/5/2025 2/5/2026
Manway At Grade Accessible Manway Accessible at Grade N/A N/A
Overfill Prev Device Overfill Alarm 3/16/2023 3/16/2026
Overfill Prev Device Overfill Drop Tube Valve 12/27/2024 12/27/2027
Piping Blending Sump 3/19/2025 3/19/2028
Leak Detect - Piping Sump Sensor with positive shutdown 2/5/2025 2/5/2026
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 3/19/2025 3/19/2028
Leak Detect - Piping Sump Sensor with positive shutdown 2/5/2025 2/5/2026
Spill Contain Device Single Wall Spill Bucket 3/28/2025 3/28/2028
Tank Fiberglass Double Wall ZCL, USA Prezerver N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Leak Detect - Piping Siphon Bar Functional Pass 3/16/2023
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 5/5/2020
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 12/27/2024
Tank Fiberglass Double Wall ZCL, USA Prezerver Precision Test (Tank) Pass 6/4/2019



Tank Number 3

Capacity: 8000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 5/24/2019 Abandoned Material:
Current Age: 6 Abandoned Date:
Install Date: 8/31/2018 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 2/5/2025 2/5/2026
Leak Detect - Tank Automatic Tank Gauging Incon TS 550 EVO 2/5/2025 2/5/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 2/5/2025 2/5/2026
Manway At Grade Accessible Manway Accessible at Grade N/A N/A
Overfill Prev Device Overfill Alarm 2/24/2025 2/24/2028
Overfill Prev Device Overfill Drop Tube Valve 3/16/2023 3/16/2026
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 3/19/2025 3/19/2028
Leak Detect - Piping Sump Sensor with positive shutdown 2/5/2025 2/5/2026
Spill Contain Device Single Wall Spill Bucket 3/28/2025 3/28/2028
Tank Fiberglass Double Wall ZCL, USA Prezerver N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 5/5/2020
Tank Fiberglass Double Wall ZCL, USA Prezerver Precision Test (Tank) Pass 6/4/2019



Tank Number 4

Capacity: 30000 Petroleum Use: None
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 5/24/2019 Abandoned Material:
Current Age: 6 Abandoned Date:
Install Date: 8/31/2018 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 2/5/2025 2/5/2026
Leak Detect - Piping Siphon Bar N/A N/A
Leak Detect - Tank Automatic Tank Gauging Incon TS 550 EVO 2/5/2025 2/5/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 2/5/2025 2/5/2026
Manway At Grade Accessible Manway Accessible at Grade N/A N/A
Overfill Prev Device Overfill Alarm 2/24/2025 2/24/2028
Overfill Prev Device Overfill Drop Tube Valve 3/16/2023 3/16/2026
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 3/19/2025 3/19/2028
Leak Detect - Piping Sump Sensor with positive shutdown 2/5/2025 2/5/2026
Piping Single Wall Transition Sump 3/19/2025 3/19/2028
Leak Detect - Piping Sump Sensor with positive shutdown 2/5/2025 2/5/2026
Spill Contain Device Single Wall Spill Bucket 3/28/2025 3/28/2028
Tank Fiberglass Double Wall ZCL, USA Prezerver N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Leak Detect - Piping Siphon Bar Functional Pass 3/16/2023
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 5/5/2020
Tank Fiberglass Double Wall ZCL, USA Prezerver Precision Test (Tank) Pass 6/4/2019



Tank Number 5

Capacity: 30000 Petroleum Use: None
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 5/24/2019 Abandoned Material:
Current Age: 6 Abandoned Date:
Install Date: 8/31/2018 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 2/5/2025 2/5/2026
Leak Detect - Piping Siphon Bar N/A N/A
Leak Detect - Tank Automatic Tank Gauging Incon TS 550 EVO 2/5/2025 2/5/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 2/5/2025 2/5/2026
Manway At Grade Accessible Manway Accessible at Grade N/A N/A
Overfill Prev Device Overfill Alarm 2/24/2025 2/24/2028
Overfill Prev Device Overfill Drop Tube Valve 3/16/2023 3/16/2026
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 3/19/2025 3/19/2028
Leak Detect - Piping Sump Sensor with positive shutdown 2/5/2025 2/5/2026
Piping Single Wall Transition Sump 3/19/2025 3/19/2028
Leak Detect - Piping Sump Sensor with positive shutdown 2/5/2025 2/5/2026
Spill Contain Device Single Wall Spill Bucket 3/28/2025 3/28/2028
Tank Fiberglass Double Wall ZCL, USA Prezerver N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Leak Detect - Piping Siphon Bar Functional Pass 3/16/2023
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 5/5/2020
Tank Fiberglass Double Wall ZCL, USA Prezerver Precision Test (Tank) Pass 6/4/2019



Tank Number 6

Capacity: 20000 Petroleum Use:
Product: B-99 CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 5/24/2019 Abandoned Material:
Current Age: 6 Abandoned Date:
Install Date: 8/31/2018 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 2/5/2025 2/5/2026
Leak Detect - Tank Automatic Tank Gauging Incon TS 550 EVO 2/5/2025 2/5/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 2/5/2025 2/5/2026
Manway At Grade Accessible Manway Accessible at Grade N/A N/A
Overfill Prev Device Overfill Alarm 3/16/2023 3/16/2026
Overfill Prev Device Overfill Drop Tube Valve 11/22/2023 11/22/2026
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 3/19/2025 3/19/2028
Leak Detect - Piping Sump Sensor with positive shutdown 2/5/2025 2/5/2026
Piping Single Wall Transition Sump 3/19/2025 3/19/2028
Leak Detect - Piping Sump Sensor with positive shutdown 2/5/2025 2/5/2026
Spill Contain Device Single Wall Spill Bucket 3/28/2025 3/28/2028
Tank Fiberglass Double Wall ZCL, USA Prezerver N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 2/5/2025
Tank Fiberglass Double Wall ZCL, USA Prezerver Precision Test (Tank) Pass 6/4/2019



Tank Number 7

Capacity: 20000 Petroleum Use: None
Product: Diesel Exhaust Fluid (Non-Regulated) CERCLA Substance:
Status: Unknown CAS Code:
Regulated Status: Non-Regulated Removed Date:
OSFM First Notify Date: 5/24/2019 Abandoned Material:
Current Age: 6 Abandoned Date:
Install Date: 8/31/2018 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection
Leak Detect - Tank Automatic Tank Gauging Incon TS 550 EVO
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors
Overfill Prev Device Overfill Alarm
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump
Spill Contain Device Field Constructed
Tank Fiberglass Double Wall ZCL, USA Prezerver N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 8

Capacity: 2000 Petroleum Use:
Product: Motor Oil CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 7/1/2019 Abandoned Material:
Current Age: 5 Abandoned Date:
Install Date: 10/25/2018 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 6/18/2019

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping European with No Test Req Suction N/A N/A
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 2/5/2025 2/5/2026
Overfill Prev Device Overfill Alarm 2/5/2025 2/5/2028
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall Transition Sump
Leak Detect - Piping Non-Discriminating Sump Sensor with positive shutdown 3/31/2022 3/31/2023
Leak Detect - Piping Piping Sump Sensors Not Regulated N/A N/A
Spill Contain Device Single Wall Spill Bucket 2/5/2025 2/5/2028
Tank Composite Double Wall Modern Welding Glasteel II N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 6/24/2019
Tank Composite Double Wall Modern Welding Glasteel II Precision Test (Tank) Pass 6/24/2019



Tank Number 9

Capacity: 8000 Petroleum Use:
Product: Motor Oil CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 7/1/2019 Abandoned Material:
Current Age: 5 Abandoned Date:
Install Date: 10/25/2018 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 6/18/2019

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping European with No Test Req Suction N/A N/A
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 2/5/2025 2/5/2026
Overfill Prev Device Overfill Alarm 2/5/2025 2/5/2028
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall Transition Sump
Leak Detect - Piping Non-Discriminating Sump Sensor with positive shutdown 3/31/2022 3/31/2023
Leak Detect - Piping Piping Sump Sensors Not Regulated N/A N/A
Spill Contain Device Single Wall Spill Bucket 2/5/2025 2/5/2028
Tank Composite Double Wall Modern Welding Glasteel II N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 6/24/2019
Tank Composite Double Wall Modern Welding Glasteel II Precision Test (Tank) Pass 6/24/2019



Tank Number 10

Capacity: 2000 Petroleum Use:
Product: Motor Oil CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 7/1/2019 Abandoned Material:
Current Age: 5 Abandoned Date:
Install Date: 10/25/2018 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 6/18/2019

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping European with No Test Req Suction N/A N/A
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 2/5/2025 2/5/2026
Overfill Prev Device Overfill Alarm 2/5/2025 2/5/2028
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall Transition Sump
Leak Detect - Piping Non-Discriminating Sump Sensor with positive shutdown 3/31/2022 3/31/2023
Leak Detect - Piping Piping Sump Sensors Not Regulated N/A N/A
Spill Contain Device Single Wall Spill Bucket 2/5/2025 2/5/2028
Tank Composite Double Wall Modern Welding Glasteel II N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 6/24/2019
Tank Composite Double Wall Modern Welding Glasteel II Precision Test (Tank) Pass 6/24/2019



Tank Number 11

Capacity: 8000 Petroleum Use:
Product: Motor Oil CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 7/1/2019 Abandoned Material:
Current Age: 5 Abandoned Date:
Install Date: 10/25/2018 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 6/18/2019

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping European with No Test Req Suction N/A N/A
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 2/5/2025 2/5/2026
Overfill Prev Device Overfill Alarm 2/5/2025 2/5/2028
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall Transition Sump
Leak Detect - Piping Non-Discriminating Sump Sensor with positive shutdown 3/31/2022 3/31/2023
Leak Detect - Piping Piping Sump Sensors Not Regulated N/A N/A
Spill Contain Device Single Wall Spill Bucket 2/5/2025 2/5/2028
Tank Composite Double Wall Modern Welding Glasteel II N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 6/24/2019
Tank Composite Double Wall Modern Welding Glasteel II Precision Test (Tank) Pass 6/24/2019



Tank Number 12

Capacity: 2000 Petroleum Use:
Product: Motor Oil CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 7/1/2019 Abandoned Material:
Current Age: 5 Abandoned Date:
Install Date: 10/25/2018 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 6/18/2019

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping European with No Test Req Suction N/A N/A
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 2/5/2025 2/5/2026
Overfill Prev Device Overfill Alarm 2/5/2025 2/5/2028
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall Transition Sump
Leak Detect - Piping Non-Discriminating Sump Sensor with positive shutdown 3/31/2022 3/31/2023
Leak Detect - Piping Piping Sump Sensors Not Regulated N/A N/A
Spill Contain Device Single Wall Spill Bucket 2/5/2025 2/5/2028
Tank Composite Double Wall Modern Welding Glasteel II N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 6/24/2019
Tank Composite Double Wall Modern Welding Glasteel II Precision Test (Tank) Pass 6/24/2019



Tank Number 13

Capacity: 7000 Petroleum Use:
Product: Used Oil CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 7/1/2019 Abandoned Material:
Current Age: 5 Abandoned Date:
Install Date: 10/25/2018 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 6/18/2019

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping European with No Test Req Suction N/A N/A
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 2/5/2025 2/5/2026
Overfill Prev Device Less than 25 gallon fills N/A N/A
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall Transition Sump
Leak Detect - Piping Non-Discriminating Sump Sensor with positive shutdown 3/31/2022 3/31/2023
Leak Detect - Piping Piping Sump Sensors Not Regulated N/A N/A
Spill Contain Device Single Wall Spill Bucket 3/28/2025 3/28/2028
Tank Composite Double Wall Modern Welding Glasteel II N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 4/15/2021
Piping Fiberglass Secondary Containment Ameron Precision Test (Piping) Pass 4/15/2021
Tank Composite Double Wall Modern Welding Glasteel II Precision Test (Tank) Pass 6/24/2019



Tank Number 14

Capacity: 2000 Petroleum Use:
Product: Motor Oil CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 7/1/2019 Abandoned Material:
Current Age: 5 Abandoned Date:
Install Date: 10/25/2018 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 6/18/2019

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping European with No Test Req Suction N/A N/A
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 2/5/2025 2/5/2026
Overfill Prev Device Overfill Alarm 2/5/2025 2/5/2028
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall Transition Sump
Leak Detect - Piping Non-Discriminating Sump Sensor with positive shutdown 3/31/2022 3/31/2023
Leak Detect - Piping Piping Sump Sensors Not Regulated N/A N/A
Spill Contain Device Single Wall Spill Bucket 2/5/2025 2/5/2028
Tank Composite Double Wall Modern Welding Glasteel II N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 6/24/2019
Tank Composite Double Wall Modern Welding Glasteel II Precision Test (Tank) Pass 6/24/2019

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/19/2025 3/19/2028
Leak Detect - Piping Sump Sensor with positive shutdown 2/5/2025 2/5/2026



Name\ID 11/12

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/19/2025 3/19/2028
Leak Detect - Piping Sump Sensor with positive shutdown 2/5/2025 2/5/2026



Name\ID 13/14

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/19/2025 3/19/2028
Leak Detect - Piping Sump Sensor with positive shutdown 2/5/2025 2/5/2026



Name\ID 17

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/19/2025 3/19/2028
Leak Detect - Piping Sump Sensor with positive shutdown 2/5/2025 2/5/2026



Name\ID 17/18

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/19/2025 3/19/2028
Leak Detect - Piping Sump Sensor with positive shutdown 2/5/2025 2/5/2026



Name\ID 18/19

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/19/2025 3/19/2028
Leak Detect - Piping Sump Sensor with positive shutdown 2/5/2025 2/5/2026



Name\ID 19/20

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/19/2025 3/19/2028
Leak Detect - Piping Sump Sensor with positive shutdown 2/5/2025 2/5/2026



Name\ID 20/21

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/19/2025 3/19/2028
Leak Detect - Piping Sump Sensor with positive shutdown 2/5/2025 2/5/2026



Name\ID 21/22

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/19/2025 3/19/2028
Leak Detect - Piping Sump Sensor with positive shutdown 2/5/2025 2/5/2026



Name\ID 22/23

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/19/2025 3/19/2028
Leak Detect - Piping Sump Sensor with positive shutdown 2/5/2025 2/5/2026



Name\ID 23/24

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/19/2025 3/19/2028
Leak Detect - Piping Sump Sensor with positive shutdown 2/5/2025 2/5/2026



Name\ID 24/25

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/19/2025 3/19/2028
Leak Detect - Piping Sump Sensor with positive shutdown 2/5/2025 2/5/2026



Name\ID 25

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/19/2025 3/19/2028
Leak Detect - Piping Sump Sensor with positive shutdown 2/5/2025 2/5/2026



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/19/2025 3/19/2028
Leak Detect - Piping Sump Sensor with positive shutdown 2/5/2025 2/5/2026



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/19/2025 3/19/2028
Leak Detect - Piping Sump Sensor with positive shutdown 2/5/2025 2/5/2026



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/19/2025 3/19/2028
Leak Detect - Piping Sump Sensor with positive shutdown 2/5/2025 2/5/2026



Name\ID 9/10

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/19/2025 3/19/2028
Leak Detect - Piping Sump Sensor with positive shutdown 2/5/2025 2/5/2026

MFD Motorfuel Dispensing Forms

Facility Number Name City Received Date Letter
2046680 Love's Travel Stop #763 Hampshire 06/10/2019 Letter Form