Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2046221
Status: Active
Facility Name: Bucky's Express #6907
Address: 1095 Pyott Road Crystal Lake, IL 60156
County: McHenry
Property Parcel: 19-16-100-020
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Y002707
Green Tag Issue Date: 5/15/2023
Green Tag Expiration Date: 12/31/2025

Owner Details

Owner Name: Casey's Retail Company
Owner Address: 3305 SE Delaware Ave. P.O. Box 3004 Ankeny, IA 50021
Owner Status: Current Owner
Purchase Date: 5/18/2021
Type of Financial Responsibility: Self-Insurance
Financial Responsibility Reporting Due Date: 1/29/2026

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 5/15/2023 12/31/2025

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0002560 Casey's Retail Company Current Owner 5/18/2021
U0032355 Buck's, Inc. Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violatlions (Current)

NOV Number: E0020251608 (Pending)    Issue Date: 6/26/2025    Expiration Date: 8/25/2025    View NOV Form

Tanks Violations
1, 2, 3 Piping interstitial must be open in all sumps - Remove all jumper tubing/pull back test boots for piping interstitial. 175.420 b. UDC'S 5/6 THROUGH 15/16.
1, 2, 3 Precision tank test required. - Precision tank test is required on tanks if you cannot provide 24 months’ worth of tank “NORMAL” from ATG WITH THE PROPER DATE.
1, 2, 3 Required monthly tank interstitial sensor records not available. - Maintain one NORMAL report per TANK, per month, from ATG. Must maintain 24 months’ worth. THE PRINTED ATG TAPES DO NOT SHOW A PROPER DATE FOR STSS TO VERIFY THE MONTH IT WAS PRINTED.

NOV Number: E0020251609 (Pending)    Issue Date: 6/26/2025    Expiration Date: 8/25/2025    View NOV Form

Tanks Violations
Facility Attendant does not have means to remotely monitor or no emergency shutoff switch 20' to 50' from dispenser - Section 175.210g; All dispensing units shall be readily visible from the control station without assistive devices. If view is permanently obstructed, or the dispenser is located so that activity is not readily visible, closed-circuit cameras that provide a view of each side of the dispensing unit and project an image on a screen at least 6 inches in diagonal located at the control station may be used. You may also elect to install an emergency stop switch at least 20 feet but no more than 50 feet from any dispenser with a permanently obstructed view.
Facility Farthest dispenser is greater than 40' and site lacks a communication system or system is inoperable - Intercom system not functional; repair/replace as necessary to provide communication at dispensers.

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 20000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/18/2017 Abandoned Material:
Current Age: 8 Abandoned Date:
Install Date: 8/25/2016 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 4/10/2017

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 1/29/2025 1/29/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 with CSLD 1/29/2025 1/29/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 1/29/2025 1/29/2026
Overfill Prev Device Overfill Alarm 2/21/2023 2/21/2026
Overfill Prev Device Overfill Drop Tube Valve 2/21/2023 2/21/2026
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 2/21/2023 2/21/2026
Leak Detect - Piping Sump Sensor with positive shutdown 1/29/2025 1/29/2026
Spill Contain Device Single Wall Spill Bucket 2/21/2023 2/21/2026
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 12000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/18/2017 Abandoned Material:
Current Age: 8 Abandoned Date:
Install Date: 8/25/2016 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 4/10/2017

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 1/29/2025 1/29/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 with CSLD 1/29/2025 1/29/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 1/29/2025 1/29/2026
Overfill Prev Device Overfill Alarm 2/21/2023 2/21/2026
Overfill Prev Device Overfill Drop Tube Valve 2/21/2023 2/21/2026
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 2/21/2023 2/21/2026
Leak Detect - Piping Sump Sensor with positive shutdown 1/29/2025 1/29/2026
Spill Contain Device Single Wall Spill Bucket 2/21/2023 2/21/2026
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 8000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/18/2017 Abandoned Material:
Current Age: 8 Abandoned Date:
Install Date: 8/25/2016 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 4/10/2017

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 1/29/2025 1/29/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 with CSLD 1/29/2025 1/29/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 1/29/2025 1/29/2026
Overfill Prev Device Overfill Alarm 2/21/2023 2/21/2026
Overfill Prev Device Overfill Drop Tube Valve 2/21/2023 2/21/2026
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 2/21/2023 2/21/2026
Leak Detect - Piping Sump Sensor with positive shutdown 1/29/2025 1/29/2026
Spill Contain Device Single Wall Spill Bucket 2/21/2023 2/21/2026
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 2/21/2023 2/21/2026
Leak Detect - Piping Sump Sensor with positive shutdown 1/29/2025 1/29/2026



Name\ID 11/12

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 2/21/2023 2/21/2026
Leak Detect - Piping Sump Sensor with positive shutdown 1/29/2025 1/29/2026



Name\ID 13/14

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 2/21/2023 2/21/2026
Leak Detect - Piping Sump Sensor with positive shutdown 1/29/2025 1/29/2026



Name\ID 15/16

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 2/21/2023 2/21/2026
Leak Detect - Piping Sump Sensor with positive shutdown 1/29/2025 1/29/2026



Name\ID 17/18

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 2/21/2023 2/21/2026
Leak Detect - Piping Sump Sensor with positive shutdown 1/29/2025 1/29/2026



Name\ID 19/20

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 2/21/2023 2/21/2026
Leak Detect - Piping Sump Sensor with positive shutdown 1/29/2025 1/29/2026



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 2/21/2023 2/21/2026
Leak Detect - Piping Sump Sensor with positive shutdown 1/29/2025 1/29/2026



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 2/21/2023 2/21/2026
Leak Detect - Piping Sump Sensor with positive shutdown 1/29/2025 1/29/2026



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 2/21/2023 2/21/2026
Leak Detect - Piping Sump Sensor with positive shutdown 1/29/2025 1/29/2026



Name\ID 9/10

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 2/21/2023 2/21/2026
Leak Detect - Piping Sump Sensor with positive shutdown 1/29/2025 1/29/2026

MFD Motorfuel Dispensing Forms

Facility Number Name City Received Date Letter
2046221 Bucky's Express #6907 Crystal Lake 04/18/2017 Letter Form
2046221 Bucky's Express #6907 Crystal Lake 04/18/2017 Letter Form