Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2046170
Status: Active
Facility Name: Grove Mart Shell
Address: 385 E. Higgins Road
Gilberts, IL 60136
County: Kane
Property Parcel:
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Z001405
Green Tag Issue Date: 3/19/2024
Green Tag Expiration Date: 12/31/2026

Owner Details

Owner Name: Jeff Glogovsky
Owner Address: 385 E. Higgins Rd.
Gilberts, IL 60136
Owner Status: Current Owner
Purchase Date:
Type of Financial Responsibility: Self-Insurance
Financial Responsibility Reporting Due Date: 6/28/2025

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 3/19/2024 12/31/2026

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0038327 Jeff Glogovsky Current Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 20000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/17/2018 Abandoned Material:
Current Age: 7 Abandoned Date:
Install Date: 9/12/2017 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 3/26/2018

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 12/3/2024 12/3/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 12/3/2024 12/3/2025
Overfill Prev Device Overfill Alarm 3/11/2025 3/11/2028
Overfill Prev Device Overfill Drop Tube Valve 3/11/2025 3/11/2028
Piping Fiberglass Double Wall NOV Fiberglass Systems Red Thread IIA fiberglass piping N/A N/A
Piping Single Wall STP/Tanktop Sump 3/11/2025 3/11/2028
Leak Detect - Piping Sump Sensor with positive shutdown 12/3/2024 12/3/2025
Spill Contain Device Double Wall Spill Bucket 3/11/2025 3/11/2028
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall NOV Fiberglass Systems Red Thread IIA fiberglass piping Precision Test (Piping) Pass 3/29/2021



Tank Number 2

Capacity: 8000 Petroleum Use:
Product: E85 CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/17/2018 Abandoned Material:
Current Age: 7 Abandoned Date:
Install Date: 9/12/2017 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 3/26/2018

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 12/3/2024 12/3/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 12/3/2024 12/3/2025
Overfill Prev Device Overfill Alarm 3/11/2025 3/11/2028
Overfill Prev Device Overfill Drop Tube Valve 3/11/2025 3/11/2028
Piping Fiberglass Double Wall NOV Fiberglass Systems Red Thread IIA fiberglass piping N/A N/A
Piping Single Wall STP/Tanktop Sump 3/11/2025 3/11/2028
Leak Detect - Piping Sump Sensor with positive shutdown 12/3/2024 12/3/2025
Spill Contain Device Double Wall Spill Bucket 3/11/2025 3/11/2028
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall NOV Fiberglass Systems Red Thread IIA fiberglass piping Precision Test (Piping) Pass 3/29/2021



Tank Number 3

Capacity: 12000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/17/2018 Abandoned Material:
Current Age: 7 Abandoned Date:
Install Date: 9/12/2017 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 3/26/2018

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 12/3/2024 12/3/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 12/3/2024 12/3/2025
Overfill Prev Device Overfill Alarm 3/11/2025 3/11/2028
Overfill Prev Device Overfill Drop Tube Valve 3/11/2025 3/11/2028
Piping Fiberglass Double Wall NOV Fiberglass Systems Red Thread IIA fiberglass piping N/A N/A
Piping Single Wall STP/Tanktop Sump 3/11/2025 3/11/2028
Leak Detect - Piping Sump Sensor with positive shutdown 12/3/2024 12/3/2025
Spill Contain Device Double Wall Spill Bucket 3/11/2025 3/11/2028
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall NOV Fiberglass Systems Red Thread IIA fiberglass piping Precision Test (Piping) Pass 3/29/2021



Tank Number 4

Capacity: 20000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/17/2018 Abandoned Material:
Current Age: 7 Abandoned Date:
Install Date: 9/12/2017 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 3/26/2018

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 12/3/2024 12/3/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 12/3/2024 12/3/2025
Overfill Prev Device Overfill Alarm 3/11/2025 3/11/2028
Overfill Prev Device Overfill Drop Tube Valve 3/11/2025 3/11/2028
Piping Fiberglass Double Wall NOV Fiberglass Systems Red Thread IIA fiberglass piping N/A N/A
Piping Single Wall STP/Tanktop Sump 3/11/2025 3/11/2028
Leak Detect - Piping Sump Sensor with positive shutdown 12/3/2024 12/3/2025
Spill Contain Device Double Wall Spill Bucket 3/11/2025 3/11/2028
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall NOV Fiberglass Systems Red Thread IIA fiberglass piping Precision Test (Piping) Pass 3/29/2021



Tank Number 5

Capacity: 6000 Petroleum Use:
Product: Diesel Exhaust Fluid (Non-Regulated) CERCLA Substance:
Status: Unknown CAS Code:
Regulated Status: Non-Regulated Removed Date:
OSFM First Notify Date: 4/17/2018 Abandoned Material:
Current Age: 7 Abandoned Date:
Install Date: 9/12/2017 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 3/26/2018

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 3/29/2018 3/29/2019
Leak Detect - Piping Sump Sensor 3/29/2018 3/29/2019
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 3/29/2018 3/29/2019
Overfill Prev Device Overfill Alarm
Piping Flexible Double Wall OmegaFlex DoubleTrac N/A N/A
Piping Other Submersible Pump N/A N/A
Piping Ball Valves N/A N/A
Piping Extractor Fitting Valves N/A N/A
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/11/2025 3/11/2028
Leak Detect - Piping Sump Sensor with positive shutdown 12/3/2024 12/3/2025



Name\ID 11/12

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/11/2025 3/11/2028
Leak Detect - Piping Sump Sensor with positive shutdown 12/3/2024 12/3/2025



Name\ID 13/14

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/11/2025 3/11/2028
Leak Detect - Piping Sump Sensor with positive shutdown 12/3/2024 12/3/2025



Name\ID 15/16

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/11/2025 3/11/2028
Leak Detect - Piping Sump Sensor with positive shutdown 12/3/2024 12/3/2025



Name\ID 17

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/11/2025 3/11/2028
Leak Detect - Piping Sump Sensor with positive shutdown 12/3/2024 12/3/2025



Name\ID 18

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/11/2025 3/11/2028
Leak Detect - Piping Sump Sensor with positive shutdown 12/3/2024 12/3/2025



Name\ID 19

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/11/2025 3/11/2028
Leak Detect - Piping Sump Sensor with positive shutdown 12/3/2024 12/3/2025



Name\ID 19 Drone

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/11/2025 3/11/2028
Leak Detect - Piping Sump Sensor with positive shutdown 12/3/2024 12/3/2025



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/11/2025 3/11/2028
Leak Detect - Piping Sump Sensor with positive shutdown 12/3/2024 12/3/2025



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/11/2025 3/11/2028
Leak Detect - Piping Sump Sensor with positive shutdown 12/3/2024 12/3/2025



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/11/2025 3/11/2028
Leak Detect - Piping Sump Sensor with positive shutdown 12/3/2024 12/3/2025



Name\ID 9/10

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/11/2025 3/11/2028
Leak Detect - Piping Sump Sensor with positive shutdown 12/3/2024 12/3/2025

MFD Motorfuel Dispensing Forms

Facility Number Name City Received Date Letter
2046170 Grove Mart Shell Gilberts 03/15/2018 Letter Form