Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2045955
Status: Active
Facility Name: Petro Stopping Center
Address: 24263 W. Lorenzo Road
Wilmington, IL 60481
County: Will
Property Parcel:
Facility Type: Commercial / Retail
Owner Type: Private
Green Tag Decal: X000330
Green Tag Issue Date: 3/16/2022
Green Tag Expiration Date: 12/31/2024

Owner Details

Owner Name: HPT TA Properties, LLC
Owner Address: 24601 Center Ridge Road
Westlake, OH 44145
Owner Status: Current Owner
Purchase Date: 6/30/2016
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 2/28/2025

Motor Fuel Dispensing Permits

No MFD Permits Found

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0034157 HPT TA Properties, LLC Current Owner 6/30/2016
U0026726 TA Operating, LLC Former Owner 9/2/2015

Permits (Unexpired)

Click for permit history

No Active Permits Found

Deficiencies (Current)

No Deficiencies Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 8000 Petroleum Use:
Product: Bulk Oil CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 3/23/2016 Abandoned Material:
Current Age: 8 Abandoned Date:
Install Date: 9/11/2015 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 3/8/2016

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping European with No Test Req Suction N/A N/A
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 300 8/13/2023 8/13/2024
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 8/13/2023 8/13/2024
Overfill Prev Device Overfill Drop Tube Valve 10/11/2021 10/11/2024
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated N/A N/A
Spill Contain Device Double Wall Spill Bucket 10/11/2021 10/11/2024
Tank Fiberglass Double Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 4000 Petroleum Use:
Product: Used Oil CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 3/23/2016 Abandoned Material:
Current Age: 8 Abandoned Date:
Install Date: 9/11/2015 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 3/8/2016

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Gravity Feed N/A N/A
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 300 8/13/2023 8/13/2024
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 8/13/2023 8/13/2024
Overfill Prev Device Less than 25 gallon fills N/A N/A
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated N/A N/A
Spill Contain Device Double Wall Spill Bucket 10/11/2021 10/11/2024
Tank Fiberglass Double Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 2500 Petroleum Use: None
Product: Used Oil CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 3/23/2016 Abandoned Material:
Current Age: 8 Abandoned Date:
Install Date: 9/11/2015 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 3/8/2016

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Gravity Feed N/A N/A
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 300 8/13/2023 8/13/2024
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 8/13/2023 8/13/2024
Overfill Prev Device Less than 25 gallon fills N/A N/A
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated N/A N/A
Spill Contain Device Double Wall Spill Bucket 10/11/2021 10/11/2024
Tank Fiberglass Double Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



MFD Motorfuel Dispensing Forms

No Forms Found