Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2045627
Status: Active
Facility Name: Costco Gasoline #383
Address: 7220 Melvina Ave Niles, IL 60714
County: Cook
Property Parcel:
Facility Type: Unattended Self-Service Station
Owner Type: Private
Green Tag Decal: Z001234
Green Tag Issue Date: 11/1/2024
Green Tag Expiration Date: 12/31/2026

Owner Details

Owner Name: Costco Wholesale Corporation
Owner Address: P.O. Box 35005 Seattle, WA 98124
Owner Status: Current Owner
Purchase Date: 8/14/2014
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 6/3/2026

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Unattended Self Service 11/1/2024 12/31/2026

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0029489 Costco Wholesale Corporation Current Owner 8/14/2014
U0037514 Costco Wholesale Licensing Department Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violatlions (Current)

NOV Number: E0020251983 (Pending)    Issue Date: 8/7/2025    Expiration Date: 10/6/2025    View NOV Form

Tanks Violations
4 Overfill prevention equipment does not appear to function properly. - Section 175.405 Spill Containment and Overfill Prevention Equipment c) Overfill prevention equipment must be inspected at installation, immediately after any repairs, and at least once every three years, and the inspection shall meet the following criteria: 1) At a minimum, the inspection must ensure that overfill prevention equipment is set to activate at the correct level specified in subsection (a); 2) The overfill prevention equipment will activate when the regulated substance reaches that level; and 3) Inspections must be conducted in accordance with inspection requirements developed by the manufacturer.

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 30000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 10/22/2014 Abandoned Material:
Current Age: 10 Abandoned Date:
Install Date: 8/14/2014 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 10/20/2014

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 7/31/2025 7/31/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 7/31/2025 7/31/2026
Overfill Prev Device Ball Only Removed Ball Float Vent Valve N/A N/A
Overfill Prev Device Overfill Alarm 7/31/2025 7/31/2028
Overfill Prev Device Overfill Drop Tube Valve 7/31/2025 7/31/2028
Piping Blending Sump 8/8/2024 8/8/2027
Piping Fiberglass Double Wall A.O. Smith N/A N/A
Piping Single Wall STP/Tanktop Sump 8/8/2024 8/8/2027
Leak Detect - Piping Sump Sensor with positive shutdown 7/31/2025 7/31/2026
Spill Contain Device Double Wall Spill Bucket 9/9/2024 9/9/2027
Tank Fiberglass Double Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Blending Sump Precision Test (Piping) Pass 7/31/2025
Piping Fiberglass Double Wall A.O. Smith Precision Test (Piping) Pass 7/31/2025
Tank Fiberglass Double Wall Containment Solutions Precision Test (Tank) Pass 8/8/2024



Tank Number 2

Capacity: 30000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 10/22/2014 Abandoned Material:
Current Age: 10 Abandoned Date:
Install Date: 8/14/2014 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 10/20/2014

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 7/31/2025 7/31/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 7/31/2025 7/31/2026
Overfill Prev Device Ball Only Removed Ball Float Vent Valve N/A N/A
Overfill Prev Device Overfill Alarm 7/31/2025 7/31/2028
Overfill Prev Device Overfill Drop Tube Valve 7/31/2025 7/31/2028
Piping Blending Sump 8/8/2024 8/8/2027
Piping Fiberglass Double Wall A.O. Smith N/A N/A
Piping Single Wall STP/Tanktop Sump 8/8/2024 8/8/2027
Leak Detect - Piping Sump Sensor with positive shutdown 8/8/2024 8/8/2025
Leak Detect - Piping Sump Sensor with positive shutdown 7/31/2025 7/31/2026
Spill Contain Device Double Wall Spill Bucket 9/9/2024 9/9/2027
Tank Fiberglass Double Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Blending Sump Precision Test (Piping) Pass 7/31/2025
Piping Fiberglass Double Wall A.O. Smith Precision Test (Piping) Pass 7/31/2025
Tank Fiberglass Double Wall Containment Solutions Precision Test (Tank) Pass 8/8/2024



Tank Number 3

Capacity: 30000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 10/22/2014 Abandoned Material:
Current Age: 10 Abandoned Date:
Install Date: 8/14/2014 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 10/20/2014

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 7/31/2025 7/31/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 7/31/2025 7/31/2026
Overfill Prev Device Ball Only Removed Ball Float Vent Valve N/A N/A
Overfill Prev Device Overfill Alarm 7/31/2025 7/31/2028
Overfill Prev Device Overfill Drop Tube Valve 7/31/2025 7/31/2028
Piping Fiberglass Double Wall A.O. Smith N/A N/A
Piping Single Wall STP/Tanktop Sump 8/8/2024 8/8/2027
Leak Detect - Piping Sump Sensor with positive shutdown 8/8/2024 8/8/2025
Leak Detect - Piping Sump Sensor with positive shutdown 7/31/2025 7/31/2026
Spill Contain Device Double Wall Spill Bucket 9/9/2024 9/9/2027
Tank Fiberglass Double Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall A.O. Smith Precision Test (Piping) Pass 7/31/2025
Tank Fiberglass Double Wall Containment Solutions Precision Test (Tank) Pass 8/8/2024



Tank Number 4

Capacity: 1500 Petroleum Use:
Product: Ultrazol - Fuel Additive CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 10/22/2014 Abandoned Material:
Current Age: 10 Abandoned Date:
Install Date: 8/14/2014 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 10/20/2014

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 7/31/2025 7/31/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 7/31/2025 7/31/2026
Overfill Prev Device Overfill Alarm 7/31/2025 7/31/2028
Overfill Prev Device Overfill Drop Tube Valve 8/8/2024 7/31/2025
Piping Fiberglass Double Wall A.O. Smith N/A N/A
Piping Single Wall STP/Tanktop Sump 8/8/2024 8/8/2027
Leak Detect - Piping Sump Sensor with positive shutdown 7/31/2025 7/31/2026
Piping Single Wall Transition Sump 8/8/2024 8/8/2027
Leak Detect - Piping Sump Sensor with positive shutdown 7/31/2025 7/31/2026
Piping Single Wall Transition Sump 8/8/2024 8/8/2027
Leak Detect - Piping Sump Sensor with positive shutdown 7/31/2025 7/31/2026
Piping Single Wall Transition Sump 8/8/2024 8/8/2027
Leak Detect - Piping Sump Sensor with positive shutdown 7/31/2025 7/31/2026
Spill Contain Device Double Wall Spill Bucket 8/11/2024 8/11/2027
Tank Fiberglass Double Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall A.O. Smith Precision Test (Piping) Pass 8/30/2022
Piping Fiberglass Double Wall A.O. Smith Precision Test (Piping) Pass 7/31/2025

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 8/8/2024 8/8/2027
Leak Detect - Piping Sump Sensor with positive shutdown 7/31/2025 7/31/2026



Name\ID 11/12

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 8/8/2024 8/8/2027
Leak Detect - Piping Sump Sensor with positive shutdown 7/31/2025 7/31/2026



Name\ID 13/14

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 8/8/2024 8/8/2027
Leak Detect - Piping Sump Sensor with positive shutdown 7/31/2025 7/31/2026



Name\ID 15/16

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 8/8/2024 8/8/2027
Leak Detect - Piping Sump Sensor with positive shutdown 7/31/2025 7/31/2026



Name\ID 17/18

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 8/8/2024 8/8/2027
Leak Detect - Piping Sump Sensor with positive shutdown 7/31/2025 7/31/2026



Name\ID 19/20

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 8/8/2024 8/8/2027
Leak Detect - Piping Sump Sensor with positive shutdown 7/31/2025 7/31/2026



Name\ID 21/22

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 8/8/2024 8/8/2027
Leak Detect - Piping Sump Sensor with positive shutdown 7/31/2025 7/31/2026



Name\ID 23/24

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 8/8/2024 8/8/2027
Leak Detect - Piping Sump Sensor with positive shutdown 7/31/2025 7/31/2026



Name\ID 25/26

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 8/8/2024 8/8/2027
Leak Detect - Piping Sump Sensor with positive shutdown 7/31/2025 7/31/2026



Name\ID 27/28

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 8/8/2024 8/8/2027
Leak Detect - Piping Sump Sensor with positive shutdown 7/31/2025 7/31/2026



Name\ID 29/30

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 8/8/2024 8/8/2027
Leak Detect - Piping Sump Sensor with positive shutdown 7/31/2025 7/31/2026



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 8/8/2024 8/8/2027
Leak Detect - Piping Sump Sensor with positive shutdown 7/31/2025 7/31/2026



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 8/8/2024 8/8/2027
Leak Detect - Piping Sump Sensor with positive shutdown 7/31/2025 7/31/2026



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 8/8/2024 8/8/2027
Leak Detect - Piping Sump Sensor with positive shutdown 7/31/2025 7/31/2026



Name\ID 9/10

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 8/8/2024 8/8/2027
Leak Detect - Piping Sump Sensor with positive shutdown 7/31/2025 7/31/2026

MFD Motorfuel Dispensing Forms

Facility Number Name City Received Date Letter
2045627 Costco Gasoline #383 Niles 05/31/2024 Letter Form
2045627 Costco Gasoline #383 Niles 02/12/2020 Letter Form