Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2045445
Status: Active
Facility Name: Thorntons Inc #314
Address: 601 Rt 83
Bensenville, IL 60106
County: Du Page
Property Parcel:
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Z000208
Green Tag Issue Date: 6/11/2024
Green Tag Expiration Date: 12/31/2026

Owner Details

Owner Name: Thorntons, LLC
Owner Address: 2600 James Thornton Way
Louisville, KY 40245
Owner Status: Current Owner
Purchase Date: 2/11/2019
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 2/18/2026

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 6/11/2024 12/31/2026

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0039521 Thorntons, LLC Current Owner 2/11/2019
U0014995 Thornton's, Inc. - DO NOT USE THIS OWNER ID Former Owner 10/1/2013

Permits (Unexpired)

Click for permit history
Permit Number Type Status OSFM Receive Date Issue Date Expiration Date Documents
00275-2025UPG Upgrade Approved / Issued 3/6/2025 3/6/2025 9/8/2025 Documents

Notice of Violations (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 20000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 10/6/2014 Abandoned Material:
Current Age: 10 Abandoned Date:
Install Date: 5/27/2014 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 8/19/2014

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 3/7/2025 3/7/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 Plus 3/7/2025 3/7/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 3/7/2025 3/7/2026
Overfill Prev Device Ball Only Removed Ball Float Vent Valve N/A N/A
Overfill Prev Device Overfill Drop Tube Valve 3/7/2025 3/7/2028
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 3/13/2023 3/13/2026
Leak Detect - Piping Sump Sensor with positive shutdown 3/7/2025 3/7/2026
Spill Contain Device Single Wall Spill Bucket 3/13/2023 3/13/2026
Tank Fiberglass Brine Filled Double Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 3/10/2022
Tank Fiberglass Brine Filled Double Wall Containment Solutions Precision Test (Tank) Pass 3/10/2022



Tank Number 2

Capacity: 6000 Petroleum Use:
Product: E85 CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 10/6/2014 Abandoned Material:
Current Age: 10 Abandoned Date:
Install Date: 5/27/2014 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 8/19/2014

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 3/7/2025 3/7/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 Plus 3/7/2025 3/7/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 3/7/2025 3/7/2026
Overfill Prev Device Ball Only Removed Ball Float Vent Valve N/A N/A
Overfill Prev Device Overfill Drop Tube Valve 3/7/2025 3/7/2028
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 3/13/2023 3/13/2026
Leak Detect - Piping Sump Sensor with positive shutdown 3/7/2025 3/7/2026
Spill Contain Device Single Wall Spill Bucket 3/13/2023 3/13/2026
Tank Fiberglass Brine Filled Double Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 3/10/2022
Tank Fiberglass Brine Filled Double Wall Containment Solutions Precision Test (Tank) Pass 3/10/2022



Tank Number 3

Capacity: 10000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 10/6/2014 Abandoned Material:
Current Age: 10 Abandoned Date:
Install Date: 5/27/2014 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 8/19/2014

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 3/7/2025 3/7/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 Plus 3/7/2025 3/7/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 3/7/2025 3/7/2026
Overfill Prev Device Ball Float Vent Valve OPW 53VML 3/7/2025 3/7/2028
Overfill Prev Device Overfill Drop Tube Valve 3/7/2025 3/7/2028
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 3/13/2023 3/13/2026
Leak Detect - Piping Sump Sensor with positive shutdown 3/7/2025 3/7/2026
Spill Contain Device Single Wall Spill Bucket 3/13/2023 3/13/2026
Tank Fiberglass Brine Filled Double Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 3/10/2022
Tank Fiberglass Brine Filled Double Wall Containment Solutions Precision Test (Tank) Pass 3/10/2022



Tank Number 4

Capacity: 6000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 10/6/2014 Abandoned Material:
Current Age: 10 Abandoned Date:
Install Date: 5/27/2014 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 8/19/2014

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 3/7/2025 3/7/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 Plus 3/7/2025 3/7/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 3/7/2025 3/7/2026
Overfill Prev Device Ball Only Removed Ball Float Vent Valve N/A N/A
Overfill Prev Device Overfill Drop Tube Valve 3/7/2025 3/7/2028
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 3/13/2023 3/13/2026
Leak Detect - Piping Sump Sensor with positive shutdown 3/12/2024 3/12/2025
Leak Detect - Piping Sump Sensor with positive shutdown 3/7/2025 3/7/2026
Spill Contain Device Single Wall Spill Bucket 3/13/2023 3/13/2026
Tank Fiberglass Brine Filled Double Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 3/10/2022
Tank Fiberglass Brine Filled Double Wall Containment Solutions Precision Test (Tank) Pass 3/10/2022



Tank Number 5

Capacity: 30000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 10/6/2014 Abandoned Material:
Current Age: 10 Abandoned Date:
Install Date: 5/30/2014 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 8/19/2014

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 3/7/2025 3/7/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 Plus 3/7/2025 3/7/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 3/7/2025 3/7/2026
Overfill Prev Device Ball Float Vent Valve OPW 53VML 3/7/2025 3/7/2028
Overfill Prev Device Overfill Drop Tube Valve 3/7/2025 3/7/2028
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 3/13/2023 3/13/2026
Leak Detect - Piping Sump Sensor with positive shutdown 3/7/2025 3/7/2026
Piping Single Wall STP/Tanktop Sump 3/13/2023 3/13/2026
Leak Detect - Piping Non-Discriminating Sump Sensor with positive shutdown 4/16/2020 4/16/2021
Leak Detect - Piping Sump Sensor with positive shutdown 3/7/2025 3/7/2026
Spill Contain Device Single Wall Spill Bucket 3/13/2023 3/13/2026
Tank Fiberglass Brine Filled Double Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 3/1/2025
Tank Fiberglass Brine Filled Double Wall Containment Solutions Precision Test (Tank) Pass 3/10/2022



Tank Number 6

Capacity: 8000 Petroleum Use:
Product: Diesel Exhaust Fluid (Non-Regulated) CERCLA Substance:
Status: Unknown CAS Code:
Regulated Status: Non-Regulated Removed Date:
OSFM First Notify Date: 10/6/2014 Abandoned Material:
Current Age: 10 Abandoned Date:
Install Date: 5/30/2014 Red Tag Issue Date:
Last Used Date: Fee Due:
Product Date: 8/19/2014

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection
Leak Detect - Piping Sump Sensor
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 Plus
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors
Overfill Prev Device Ball Float Vent Valve OPW 53VML
Overfill Prev Device Overfill Alarm
Spill Contain Device Single Wall Spill Bucket
Tank Fiberglass Double Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/13/2023 3/13/2026
Leak Detect - Piping Sump Sensor with positive shutdown 3/7/2025 3/7/2026



Name\ID 11/12

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/13/2023 3/13/2026
Leak Detect - Piping Sump Sensor with positive shutdown 3/7/2025 3/7/2026



Name\ID 13/14

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/13/2023 3/13/2026
Leak Detect - Piping Sump Sensor with positive shutdown 3/7/2025 3/7/2026



Name\ID 15/16

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/13/2023 3/13/2026
Leak Detect - Piping Sump Sensor with positive shutdown 3/7/2025 3/7/2026



Name\ID 17/18

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/13/2023 3/13/2026
Leak Detect - Piping Sump Sensor with positive shutdown 3/7/2025 3/7/2026



Name\ID 19/20

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/13/2023 3/13/2026
Leak Detect - Piping Sump Sensor with positive shutdown 3/7/2025 3/7/2026



Name\ID 21

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/13/2023 3/13/2026
Leak Detect - Piping Sump Sensor with positive shutdown 3/7/2025 3/7/2026



Name\ID 22

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/13/2023 3/13/2026
Leak Detect - Piping Sump Sensor with positive shutdown 3/7/2025 3/7/2026



Name\ID 23

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/13/2023 3/13/2026
Leak Detect - Piping Sump Sensor with positive shutdown 3/7/2025 3/7/2026



Name\ID 24

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/13/2023 3/13/2026
Leak Detect - Piping Sump Sensor with positive shutdown 3/7/2025 3/7/2026



Name\ID 25

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/13/2023 3/13/2026
Leak Detect - Piping Sump Sensor with positive shutdown 3/12/2024 3/12/2025



Name\ID 26

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/13/2023 3/13/2026
Leak Detect - Piping Sump Sensor with positive shutdown 3/7/2025 3/7/2026



Name\ID 27/28

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/13/2023 3/13/2026
Leak Detect - Piping Sump Sensor with positive shutdown 3/7/2025 3/7/2026



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/13/2023 3/13/2026
Leak Detect - Piping Sump Sensor with positive shutdown 3/7/2025 3/7/2026



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/13/2023 3/13/2026
Leak Detect - Piping Sump Sensor with positive shutdown 3/7/2025 3/7/2026



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/13/2023 3/13/2026
Leak Detect - Piping Sump Sensor with positive shutdown 3/7/2025 3/7/2026



Name\ID 9/10

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/13/2023 3/13/2026
Leak Detect - Piping Sump Sensor with positive shutdown 3/7/2025 3/7/2026

MFD Motorfuel Dispensing Forms

No Forms Found