Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2045427
Status: Active
Facility Name: Greco and Sons, Inc.
Address: 1550 Hecht Dr. Bartlett, IL 60103
County: Du Page
Property Parcel:
Facility Type: Commercial / Retail
Owner Type: Private
Green Tag Decal: Y003816
Green Tag Issue Date: 8/31/2023
Green Tag Expiration Date: 12/31/2025

Owner Details

Owner Name: Greco and Sons, Inc.
Owner Address: 1550 Hecht Dr. Bartlett, IL 60103
Owner Status: Current Owner
Purchase Date:
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 2/9/2024

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Fleet 8/31/2023 12/31/2025

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0036963 Greco and Sons, Inc. Current Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violatlions (Current)

NOV Number: E0020252906 (Pending)    Issue Date: 10/29/2025    Expiration Date: 12/28/2025    View NOV Form

Tanks Violations
Facility Annual Emergency Stop Inspection not completed or inspection report not available. - Emergency shut off switch needs annual testing performed. OSFM form shall be kept on site.
1 Annual leak detection certification not completed (Required annually). - Annual leak detection testing shall be performed and passing results entered on OSFM portal.
1 Annual leak detection certification not completed (Required annually). - Line leak detectors need annual testing. Testing shall be performed and passing results entered on OSFM portal.
1 Document that emergency shut-off (shear valves) are in proper working order - Shear valves need annual testing performed. OSFM form shall be completed and kept on site.
Facility Emergency contact information for A/B & C Operators not posted at unmanned facility - Sign needs to be installed near tank stating "In Case Of Fueling Emergencies Contact A/B Operator Phone Number"
Facility Financial responsibility must be reported yearly - Section 176.220 Proof of Financial Responsibility a) Proof of financial responsibility for Section 176.215(a), (b), (c), (d) or (e) shall be maintained on the respective OSFM forms, which may be complemented by industry customs and practices so long as the OSFM form language is utilized. The forms are available at https://sfm.illinois.gov/about/divisions/petroleumchemical- safety/applications-and-forms.html
1 Line interstitial sensor functional test not accomplished (Required annually). - STP and UDC Sump Sensors need annual testing. STP and UDC sump sensors need annual testing performed. Passing results shall be entered on OSFM portal.
1 Line interstitial sensors have been raised and rendered inoperational. - Section 175.640 a)2) All new and existing sump sensors must be installed so as to detect liquid per manufacturer's specifications or, if not specified by the manufacturer, at the lowest point in the sump.
Facility Missing copies of Annual Walkthrough Inspection Report. - Annual walkthrough needs to be performed. OSFM form shall be completed and kept on site.
1 Overfill alarm does not appear to function properly. - Overfill alarm audible alarm does not work when tested.
1 Tank interstitial sensor functional test not accomplished (Required annually). - Annual leak detection testing shall be performed and passing results entered on OSFM portal.

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 10000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 12/3/2013 Abandoned Material:
Current Age: 12 Abandoned Date:
Install Date: 9/6/2013 Red Tag Issue Date:
Last Used Date: Fee Due:
Product Date: 10/15/2013

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 10/30/2025 10/30/2026
Leak Detect - Tank Automatic Tank Gauging OPW Site Sentinel Nano 10/30/2025 10/30/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 10/30/2025 10/30/2026
Overfill Prev Device Overfill Alarm 2/8/2024 2/8/2027
Overfill Prev Device Overfill Drop Tube Valve 2/8/2024 2/8/2027
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 2/8/2024 2/8/2027
Leak Detect - Piping Non-Discriminating Sump Sensor 6/17/2019 6/17/2020
Leak Detect - Piping Sump Sensor with positive shutdown 10/30/2025 10/30/2026
Spill Contain Device Single Wall Spill Bucket 2/8/2024 2/8/2027
Tank Fiberglass Double Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 2/16/2022

Dispenser Information



Name\ID 1 Master

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 2/8/2024 2/8/2027
Leak Detect - Piping Sump Sensor with positive shutdown 10/30/2025 10/30/2026



Name\ID 1 Sat

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 2/8/2024 2/8/2027
Leak Detect - Piping Sump Sensor with positive shutdown 10/30/2025 10/30/2026

MFD Motorfuel Dispensing Forms

No Forms Found