Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2045417
Status: Active
Facility Name: New Prime, Inc.
Address: 5444 W. 73rd St. Bedford Park, IL 60501
County: Cook
Property Parcel: 19-28-100-049
Facility Type: Trucking Company
Owner Type: Private
Green Tag Decal: Z000282
Green Tag Issue Date: 6/13/2024
Green Tag Expiration Date: 12/31/2026

Owner Details

Owner Name: New Prime, Inc.
Owner Address: 2740 N. Mayfair Avenue Springfield, MO 65803
Owner Status: Current Owner
Purchase Date: 6/23/2023
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 5/22/2026

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Fleet 1/27/2022 12/31/2024

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0041218 New Prime, Inc. Current Owner 6/23/2023
U0036943 Intermodal Maintenance Former Owner 9/1/2014
U0039443 Pasco, Julia Former Owner 6/12/2014

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violatlions (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 10000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 10/6/2014 Abandoned Material:
Current Age: 11 Abandoned Date:
Install Date: 9/18/2013 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 10/24/2024 10/24/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 300c 10/24/2024 10/24/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 10/24/2024 10/24/2025
Overfill Prev Device Overfill Drop Tube Valve 10/20/2022 10/20/2025
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 10/20/2022 10/20/2025
Leak Detect - Piping Non-Discriminating Sump Sensor 10/23/2019 10/23/2020
Leak Detect - Piping Non-Discriminating Sump Sensor with positive shutdown 10/23/2020 10/23/2021
Leak Detect - Piping Sump Sensor with positive shutdown 10/24/2024 10/24/2025
Spill Contain Device Single Wall Spill Bucket 10/20/2022 10/20/2025
Tank Fiberglass Double Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 10/24/2024

Dispenser Information



Name\ID East

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 10/20/2022 10/20/2025
Leak Detect - Piping Sump Sensor with positive shutdown 10/24/2024 10/24/2025



Name\ID West

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 10/20/2022 10/20/2025
Leak Detect - Piping Sump Sensor with positive shutdown 10/24/2024 10/24/2025

MFD Motorfuel Dispensing Forms

No Forms Found