Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2045225
Status: Closed
Facility Name: Midway Between Runway 4R & 4L
Address: 5169 W. 63rd Street Chicago, IL 60638
County: Cook
Property Parcel:
Facility Type: Airport
Owner Type: Federal
Green Tag Decal: R001564
Green Tag Issue Date: 9/22/2016
Green Tag Expire Date: 12/31/2018
MFD Type: N/A

Owner Details

Owner Name: Federal Aviation Administration
Owner Address: 1100 Bowes Road Chicago System Management Office Elgin, IL 60123
Owner Status: Current Owner
Purchase Date:
Type of Financial Responsibility: Self-Insurance
Financial Responsibility Reporting Due Date: 6/30/2017

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0005059 Federal Aviation Administration Current Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 600 Petroleum Use: Back-up Generator
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 4/4/2017
OSFM First Notify Date: 12/5/2012 Abandoned Material:
Current Age: 4 Abandoned Date:
Install Date: 11/2/2012 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 11/3/2012

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive Not applicable Not applicable
Corrosion Prot - Piping Flexible Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping American with Sensors/No Test Suction Not applicable Not applicable
Leak Detect - Piping Sump Sensor 8/16/2016 8/16/2017
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 No passing test found No passing test found
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 8/16/2016 8/16/2017
Overfill Prev Device Ball Float Vent Valve No passing test found No passing test found
Overfill Prev Device Overfill Alarm No passing test found No passing test found
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Not applicable Not applicable
Piping Flexible Double Wall Western Co-Flex Not applicable Not applicable
Spill Contain Device Single Wall Spill Bucket No passing test found No passing test found
Tank Fiberglass Double Wall XERXES Not applicable Not applicable

Additional Tests

No Tests Listed


Failed test = the latest test has failed.

Not applicable = a test does not apply to this equipment type or configuration.

No passing test found = a passing test is expected but was not found from the source data.


Dispenser Information




Failed test = the latest test has failed.

Not applicable = a test does not apply to this equipment type or configuration.

No passing test found = a passing test is expected but was not found from the source data.


MFD Motorfuel Dispensing Forms

No Forms Found