Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2044196
Status: Active
Facility Name: UNFI Wholesale, Inc.
Address: 2600 Haven W. Joliet, IL 60433
County: Will
Property Parcel: 15-08-19-101-009-0000
Facility Type: Trucking Company
Owner Type: Private
Green Tag Decal: AA04309
Green Tag Issue Date: 9/17/2025
Green Tag Expiration Date: 12/31/2027

Owner Details

Owner Name: SV Distribution Joliet Illinois, LLC
Owner Address: 313 Iron Horse Way Providence, RI 02908
Owner Status: Current Owner
Purchase Date: 10/23/2018
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 3/14/2026

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Fleet 9/17/2025 12/31/2027

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0041173 SV Distribution Joliet Illinois, LLC Current Owner 10/23/2018
U0038904 SuperValu Holdings, Inc. Former Owner 9/14/2017
U0034995 Central Grocers Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violatlions (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 25000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 3/10/2009 Abandoned Material:
Current Age: 16 Abandoned Date:
Install Date: 12/4/2008 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 12/5/2008

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 9/30/2024 9/30/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 300c 9/2/2025 9/2/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 9/2/2025 9/2/2026
Overfill Prev Device Overfill Drop Tube Valve 10/3/2024 10/3/2027
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 9/9/2025 9/9/2028
Leak Detect - Piping Sump Sensor 9/2/2025 9/2/2026
Spill Contain Device Single Wall Spill Bucket 9/9/2025 9/9/2028
Tank Fiberglass Double Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 9/2/2025



Tank Number 2

Capacity: 10000 Petroleum Use:
Product: Dyed Diesel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 3/10/2009 Abandoned Material:
Current Age: 16 Abandoned Date:
Install Date: 12/4/2008 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 12/5/2008

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 9/2/2025 9/2/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 300c 9/2/2025 9/2/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 9/2/2025 9/2/2026
Overfill Prev Device Overfill Drop Tube Valve 10/3/2024 10/3/2027
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 9/9/2025 9/9/2028
Leak Detect - Piping Sump Sensor 9/2/2025 9/2/2026
Spill Contain Device Single Wall Spill Bucket 9/9/2025 9/9/2028
Tank Fiberglass Double Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 9/2/2025

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 9/9/2025 9/9/2028
Leak Detect - Piping Sump Sensor 9/2/2025 9/2/2026



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 9/9/2025 9/9/2028
Leak Detect - Piping Sump Sensor 9/2/2025 9/2/2026

MFD Motorfuel Dispensing Forms

No Forms Found