Owner Summary
Click for Facility/Tank Ownership history
| Owner Number |
Owner Name |
Owner Status |
Purchase Date |
| U0035671 |
RDK Ventures LLC |
Current Owner |
11/7/2011 |
| U0033587 |
Jetco Properties, Inc. |
Former Owner |
6/2/2006 |
| U0032956 |
Albertson's, Inc. |
Former Owner |
10/12/2005 |
Notice of Violations (Current)
No Notice of Violations Found
IEMA Numbers Associated with the Facility
No IEMA Numbers Found
LUST
Fund Eligibility and Deductibility Determinations
No Applications Found
Tank Number 1
| Capacity: |
15000 |
|
Petroleum Use: |
|
| Product: |
Gasoline - Regular |
|
CERCLA Substance: |
|
| Status: |
Currently in use |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
|
|
OSFM
First Notify Date: |
1/25/2006 |
|
Abandoned Material: |
|
| Current Age: |
20 |
|
Abandoned Date: |
|
| Install Date: |
10/13/2005 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
1/4/2006 |
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Flexible Non-Corrosive |
Not applicable |
Not applicable |
|
Corrosion Prot - Tank
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Leak Detect - Piping
|
Electronic Pressurized Line Leak Detection |
4/20/2026 |
4/20/2027 |
|
Leak Detect - Tank
|
Automatic Tank Gauging Veeder Root TLS 350R with CSLD |
4/20/2026 |
4/20/2027 |
|
Leak Detect - Tank
|
Hydrostatic Reservoir Interstitial Monitoring Sensors |
4/20/2026 |
4/20/2027 |
|
Overfill Prev Device
|
Ball Only Removed Ball Float Vent Valve |
Not applicable |
Not applicable |
|
Overfill Prev Device
|
Overfill Alarm |
5/1/2024 |
5/1/2027 |
|
Overfill Prev Device
|
Overfill Drop Tube Valve |
5/1/2024 |
5/1/2027 |
|
Piping
|
Flexible Double Wall Environ Geo Flex |
Not applicable |
Not applicable |
|
Piping
|
Single Wall STP/Tanktop Sump |
11/28/2023 |
11/28/2026 |
Leak Detect - Piping
|
Sump Sensor |
11/28/2023 |
11/28/2026 |
|
Spill Contain Device
|
Double Wall Spill Bucket |
4/20/2026 |
4/20/2029 |
|
Tank
|
Fiberglass Brine Filled Double Wall XERXES |
Not applicable |
Not applicable |
Additional Tests
| Equipment Type |
Equipment |
Test Type |
Test Result |
Test Date |
|
Piping
|
Flexible Double Wall Environ Geo Flex
|
Precision Test (Piping)
|
Pass
|
4/20/2026
|
|
Tank
|
Fiberglass Brine Filled Double Wall XERXES
|
Precision Test (Tank)
|
Pass
|
3/28/2022
|
|
Leak Detect - Tank
|
Hydrostatic Reservoir Interstitial Monitoring Sensors
|
Sensor Functional
|
Pass
|
1/14/2010
|
|
Leak Detect - Piping
|
Non-Discriminating Sump Sensor
|
Sensor Functional
|
Pass
|
1/14/2010
|
Tank Number 2
| Capacity: |
10000 |
|
Petroleum Use: |
|
| Product: |
Gasoline - Premium |
|
CERCLA Substance: |
|
| Status: |
Currently in use |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
|
|
OSFM
First Notify Date: |
1/25/2006 |
|
Abandoned Material: |
|
| Current Age: |
20 |
|
Abandoned Date: |
|
| Install Date: |
10/13/2005 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
1/4/2006 |
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Flexible Non-Corrosive |
Not applicable |
Not applicable |
|
Corrosion Prot - Tank
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Leak Detect - Piping
|
Electronic Pressurized Line Leak Detection |
4/20/2026 |
4/20/2027 |
|
Leak Detect - Tank
|
Automatic Tank Gauging Veeder Root TLS 350R with CSLD |
4/20/2026 |
4/20/2027 |
|
Leak Detect - Tank
|
Hydrostatic Reservoir Interstitial Monitoring Sensors |
4/20/2026 |
4/20/2027 |
|
Overfill Prev Device
|
Ball Only Removed Ball Float Vent Valve |
Not applicable |
Not applicable |
|
Overfill Prev Device
|
Overfill Alarm |
5/1/2024 |
5/1/2027 |
|
Overfill Prev Device
|
Overfill Drop Tube Valve |
5/1/2024 |
5/1/2027 |
|
Piping
|
Flexible Double Wall Environ Geo Flex |
Not applicable |
Not applicable |
|
Piping
|
Single Wall STP/Tanktop Sump |
11/28/2023 |
11/28/2026 |
Leak Detect - Piping
|
Sump Sensor |
11/28/2023 |
11/28/2026 |
|
Spill Contain Device
|
Double Wall Spill Bucket |
4/20/2026 |
4/20/2029 |
|
Tank
|
Fiberglass Brine Filled Double Wall XERXES |
Not applicable |
Not applicable |
Additional Tests
| Equipment Type |
Equipment |
Test Type |
Test Result |
Test Date |
|
Piping
|
Flexible Double Wall Environ Geo Flex
|
Precision Test (Piping)
|
Pass
|
4/20/2026
|
|
Tank
|
Fiberglass Brine Filled Double Wall XERXES
|
Precision Test (Tank)
|
Pass
|
3/28/2022
|
|
Leak Detect - Tank
|
Hydrostatic Reservoir Interstitial Monitoring Sensors
|
Sensor Functional
|
Pass
|
1/14/2010
|
|
Leak Detect - Piping
|
Non-Discriminating Sump Sensor
|
Sensor Functional
|
Pass
|
1/14/2010
|
Failed test = the latest test has failed.
Not applicable = a test does not apply to this equipment type or configuration.
No passing test found = a passing test is expected but was not found from the source data.
Dispenser Information
Name\ID 1/2
| Status: |
Active |
|
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Dispenser
|
Single Wall UDC Sump |
11/28/2023
|
11/28/2026
|
Leak Detect - Piping
|
Sump Sensor |
4/20/2026
|
4/20/2027
|
Name\ID 3/4
| Status: |
Active |
|
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Dispenser
|
Single Wall UDC Sump |
11/28/2023
|
11/28/2026
|
Leak Detect - Piping
|
Sump Sensor |
4/20/2026
|
4/20/2027
|
Name\ID 5/6
| Status: |
Active |
|
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Dispenser
|
Single Wall UDC Sump |
11/28/2023
|
11/28/2026
|
Leak Detect - Piping
|
Sump Sensor |
4/20/2026
|
4/20/2027
|
Name\ID 7/8
| Status: |
Active |
|
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Dispenser
|
Single Wall UDC Sump |
11/28/2023
|
11/28/2026
|
Leak Detect - Piping
|
Sump Sensor |
4/20/2026
|
4/20/2027
|
Failed test = the latest test has failed.
Not applicable = a test does not apply to this equipment type or configuration.
No passing test found = a passing test is expected but was not found from the source data.
MFD
Motorfuel Dispensing Forms
No Forms Found