Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2042512
Status: Active
Facility Name: Home City Ice
Address: 1125 International Parkway Woodridge, IL 60515
County: Du Page
Property Parcel:
Facility Type: Commercial / Retail
Owner Type: Private
Green Tag Decal: BB04293
Green Tag Issue Date: 2/24/2026
Green Tag Expire Date: 12/31/2028
MFD Type: Fleet

Owner Details

Owner Name: Home City Ice
Owner Address:
Owner Status: Current Owner
Purchase Date:
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 1/15/2027

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0032350 Home City Ice Current Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 10000 Petroleum Use: None
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 5/25/2005 Abandoned Material:
Current Age: 21 Abandoned Date:
Install Date: 11/24/2004 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 2/13/2026 2/13/2027
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 2/13/2026 2/13/2027
Overfill Prev Device Ball Float Vent Valve 2/13/2026 2/13/2029
Piping Flexible Double Wall A.P.T. Poly Tech Not applicable Not applicable
Piping Single Wall STP/Tanktop Sump 2/13/2026 2/13/2029
Leak Detect - Piping Sump Sensor 2/13/2026 2/13/2029
Spill Contain Device Single Wall Spill Bucket 2/13/2026 2/13/2029
Tank Fiberglass Double Wall Containment Solutions Not applicable Not applicable

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall A.P.T. Poly Tech Precision Test (Piping) Pass 2/13/2026
Tank Fiberglass Double Wall Containment Solutions Precision Test (Tank) Pass 8/23/2024

Failed test = the latest test has failed.

Not applicable = a test does not apply to this equipment type or configuration.

No passing test found = a passing test is expected but was not found from the source data.


Dispenser Information



Name\ID 1

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 2/13/2026 2/13/2029
Leak Detect - Piping Sump Sensor 2/13/2026 2/13/2027

Failed test = the latest test has failed.

Not applicable = a test does not apply to this equipment type or configuration.

No passing test found = a passing test is expected but was not found from the source data.


MFD Motorfuel Dispensing Forms