Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2042220
Status: Active
Facility Name: IL0103
Address: 5151 Sauk Trail
Richton Park, IL 60471
County: Cook
Property Parcel: 31-33-101-041-0000
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Z001362
Green Tag Issue Date: 12/19/2024
Green Tag Expiration Date: 12/31/2026

Owner Details

Owner Name: Lehigh Gas Wholesale Services
Owner Address: 645 Hamilton, Suite 400
Allentown, PA 18101
Owner Status: Current Owner / Operator
Purchase Date: 9/27/2016
Type of Financial Responsibility: Surety Bond
Financial Responsibility Reporting Due Date: 6/12/2025

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 12/19/2024 12/31/2026

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0037337 Lehigh Gas Wholesale Services Current Owner / Operator 9/27/2016
U0025164 BAPA, LLC & PT, LLC Former Owner / Operator 7/1/2008
U0032036 First Gas, Inc. Former Owner / Operator

Permits (Unexpired)

Click for permit history
Permit Number Type Status OSFM Receive Date Issue Date Expiration Date Documents
00007-2025ABN Abandon in Place Approved / Issued 12/31/2024 1/4/2025 7/5/2025 Documents

Notice of Violations (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
2024-0954 2/13/2025 Abandonment Log 00007-2025ABN

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
20240954 Ineligible 3/5/2025 3/6/2025 $No Deductible Letter
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 12000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 1/8/2009 Abandoned Material:
Current Age: 20 Abandoned Date:
Install Date: 3/1/2005 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 1/31/2023 1/31/2026
Corrosion Prot - Piping Sacrificial Anode Flex Connector 1/31/2023 1/31/2026
Corrosion Prot - Piping Sacrificial Anode Flex Connector 1/31/2023 1/31/2026
Corrosion Prot - Piping Sacrificial Anode Flex Connector 1/31/2023 1/31/2026
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 3/12/2025 3/12/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 3/12/2025 3/12/2026
Overfill Prev Device Overfill Drop Tube Valve 3/26/2024 3/26/2027
Piping Flexible Double Wall Environ Geo Flex N/A N/A
Piping Single Wall STP/Tanktop Sump 10/10/2024 10/10/2027
Leak Detect - Piping Sump Sensor 3/12/2025 3/12/2026
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 10/10/2024 10/10/2027
Tank Composite Double Wall Modern Welding Glasteel II N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Environ Geo Flex Precision Test (Piping) Pass 3/12/2025



Tank Number 2

Capacity: 6000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 1/8/2009 Abandoned Material:
Current Age: 20 Abandoned Date:
Install Date: 3/1/2005 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 1/31/2023 1/31/2026
Corrosion Prot - Piping Sacrificial Anode Flex Connector 1/31/2023 1/31/2026
Corrosion Prot - Piping Sacrificial Anode Flex Connector 1/31/2023 1/31/2026
Corrosion Prot - Piping Sacrificial Anode Flex Connector 1/31/2023 1/31/2026
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 3/12/2025 3/12/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 3/12/2025 3/12/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 3/12/2025 3/12/2026
Overfill Prev Device Overfill Drop Tube Valve 3/26/2024 3/26/2027
Piping Flexible Double Wall Environ Geo Flex N/A N/A
Piping Single Wall STP/Tanktop Sump 10/10/2024 10/10/2027
Leak Detect - Piping Sump Sensor 3/12/2025 3/12/2026
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 10/10/2024 10/10/2027
Tank Composite Double Wall Modern Welding Glasteel II N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Environ Geo Flex Precision Test (Piping) Pass 3/12/2025



Tank Number 3

Capacity: 6000 Petroleum Use:
Product: E85 CERCLA Substance:
Status: Abandoned in place CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 1/8/2009 Abandoned Material: Tripolymer Foam
Current Age: 20 Abandoned Date: 2/13/2025
Install Date: 3/1/2005 Red Tag Issue Date:
Last Used Date: 8/24/2012 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection
Leak Detect - Piping Sump Sensor
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350
Overfill Prev Device Overfill Drop Tube Valve
Piping Flexible Double Wall Total Containment Omniflex II N/A N/A
Spill Contain Device Single Wall Spill Bucket
Tank Composite Double Wall Modern Welding Glasteel II N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 4

Capacity: 3000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 1/8/2009 Abandoned Material:
Current Age: 20 Abandoned Date:
Install Date: 3/1/2005 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 1/31/2023 1/31/2026
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 3/12/2025 3/12/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 3/12/2025 3/12/2026
Overfill Prev Device Overfill Drop Tube Valve 3/26/2024 3/26/2027
Piping Flexible Double Wall Environ Geo Flex N/A N/A
Piping Single Wall STP/Tanktop Sump 10/10/2024 10/10/2027
Leak Detect - Piping Sump Sensor 3/12/2025 3/12/2026
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 10/10/2024 10/10/2027
Tank Composite Double Wall Modern Welding Glasteel II N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Environ Geo Flex Precision Test (Piping) Pass 3/12/2025

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 9/10

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A

MFD Motorfuel Dispensing Forms

No Forms Found