Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2041888
Status: Active
Facility Name: Citgo Gas & Mini-Mart
Address: 1530 W. 111th Street
Chicago, IL 60643
County: Cook
Property Parcel:
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: AA02327
Green Tag Issue Date: 2/19/2025
Green Tag Expiration Date: 12/31/2027

Owner Details

Owner Name: Mohamed Elnatour
Owner Address: 9229 S Beloit Ave
Bridgeview, IL 60455
Owner Status: Current Owner
Purchase Date:
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 11/19/2025

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 2/19/2025 12/31/2027

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0031569 Elnatour, Mohamed Current Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 12000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 7/30/2004 Abandoned Material:
Current Age: 21 Abandoned Date:
Install Date: 10/23/2003 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 10/23/2003

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 10/3/2024 10/3/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 10/3/2024 10/3/2025
Overfill Prev Device Overfill Drop Tube Valve 3/13/2023 3/13/2026
Piping Flexible Double Wall N/A N/A
Piping Single Wall STP/Tanktop Sump 3/13/2023 3/13/2026
Leak Detect - Piping Sump Sensor 10/3/2024 10/3/2025
Spill Contain Device Single Wall Spill Bucket 3/13/2023 3/13/2026
Tank Composite Double Wall Modern Welding Glasteel II N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Precision Test (Piping) Pass 10/3/2024
Tank Composite Double Wall Modern Welding Glasteel II Precision Test (Tank) Pass 3/13/2023



Tank Number 2

Capacity: 8000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 7/30/2004 Abandoned Material:
Current Age: 21 Abandoned Date:
Install Date: 10/23/2003 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 10/23/2003

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 10/3/2024 10/3/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 11/13/2024 11/13/2025
Overfill Prev Device Overfill Drop Tube Valve 3/13/2023 3/13/2026
Piping Flexible Double Wall N/A N/A
Piping Single Wall STP/Tanktop Sump 3/13/2023 3/13/2026
Leak Detect - Piping Sump Sensor 10/3/2024 10/3/2025
Spill Contain Device Single Wall Spill Bucket 3/13/2023 3/13/2026
Tank Composite Double Wall Modern Welding Glasteel II N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Precision Test (Piping) Pass 10/3/2024
Tank Composite Double Wall Modern Welding Glasteel II Precision Test (Tank) Pass 3/13/2023



Tank Number 3

Capacity: 4000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 7/30/2004 Abandoned Material:
Current Age: 21 Abandoned Date:
Install Date: 10/23/2003 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 10/23/2003

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 10/3/2024 10/3/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 10/3/2024 10/3/2025
Overfill Prev Device Overfill Drop Tube Valve 3/13/2023 3/13/2026
Piping Flexible Double Wall N/A N/A
Piping Single Wall STP/Tanktop Sump 3/13/2023 3/13/2026
Leak Detect - Piping Sump Sensor 10/3/2024 10/3/2025
Spill Contain Device Single Wall Spill Bucket 3/13/2023 3/13/2026
Tank Composite Double Wall Modern Welding Glasteel II N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Precision Test (Piping) Pass 10/3/2024
Tank Composite Double Wall Modern Welding Glasteel II Precision Test (Tank) Pass 3/13/2023

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 5/25/2023 5/25/2026
Leak Detect - Piping Sump Sensor 10/3/2024 10/3/2025



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 5/25/2023 5/25/2026
Leak Detect - Piping Sump Sensor 10/3/2024 10/3/2025



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 5/25/2023 5/25/2026
Leak Detect - Piping Sump Sensor 10/3/2024 10/3/2025



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 5/25/2023 5/25/2026
Leak Detect - Piping Sump Sensor 10/3/2024 10/3/2025

MFD Motorfuel Dispensing Forms

No Forms Found