Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2041824
Status: Active
Facility Name: BP Gas and Food, Inc.
Address: 2200 W. Galena Blvd. Aurora, IL 60504
County: Kane
Property Parcel: 15-19-180-008
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Y003354
Green Tag Issue Date: 11/14/2023
Green Tag Expiration Date: 12/31/2025

Owner Details

Owner Name: Galena Real Estate, LLC
Owner Address: 401 Hawkcrest Circle Sacramento, CA 95835
Owner Status: Current Owner
Purchase Date: 4/20/2021
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 2/25/2024

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 3/21/2023 12/31/2025

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0040400 Galena Real Estate, LLC Current Owner 4/20/2021
U0035073 Galena Gasoline, Inc. Former Owner 10/21/2008
U0000552 BP Products North America, Inc. Former Owner 11/7/2003

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violatlions (Current)

NOV Number: E0020252763 (Pending)    Issue Date: 10/20/2025    Expiration Date: 12/19/2025    View NOV Form

Tanks Violations
1, 2 Annual electronic line leak detector test not completed. - Line leak detectors need annual testing. Testing shall be performed and passing results entered on OSFM portal.
Facility Annual Emergency Stop Inspection not completed or inspection report not available. - Emergency shut off switch needs annual testing performed. OSFM form shall be kept on site.
1, 2 Annual leak detection certification not completed (Required annually). - Annual leak detection testing shall be performed and passing results entered on OSFM portal.
1, 2 Document that emergency shut-off (shear valves) are in proper working order - Shear valves need annual testing performed. OSFM form shall be completed and kept on site.
Facility Financial responsibility must be reported yearly - Section 176.220 Proof of Financial Responsibility a) Proof of financial responsibility for Section 176.215(a), (b), (c), (d) or (e) shall be maintained on the respective OSFM forms, which may be complemented by industry customs and practices so long as the OSFM form language is utilized. The forms are available at https://sfm.illinois.gov/about/divisions/petroleumchemical- safety/applications-and-forms.html
1, 2 Line interstitial sensor functional test not accomplished (Required annually). - STP, UDC, and Transition sumps need annual sensor testing. All sensors shall be tested with passing results entered on OSFM portal. STP and UDC sump sensors need annual testing performed. Passing results shall be entered on OSFM portal.
2 Line interstitial sensors have been raised and rendered inoperational. - Premium STP sump sensor is raised. 175.640 a) 2) All new and existing sump sensors must be installed so as to detect liquid per manufacturer's specifications or, if not specified by the manufacturer, at the lowest point in the sump.
1 Miscellaneous - Probe or tank sensor well needs lid secured properly.
Facility Missing copies of Annual Walkthrough Inspection Report. - Annual walkthrough needs to be performed. OSFM form shall be completed and kept on site.
1, 2 Piping interstitial must be open in all sumps - 175.420 b) Unless otherwise required by the manufacturer, the dispenser product piping sump jumper tubes shall be removed, or the product piping test boots pulled back after testing to allow the interstice to be open to the sump sensors. This is for all sumps.
1, 2 Spill prevention equipment contains liquid/debris and must be cleared of materials and maintained clean and dry. - 175.405 a) 1) A) Spill containment equipment that will prevent release of product to the environment when the transfer hose is detached from the fill pipe (e.g., a spill catch basin). Spill containment equipment shall be maintained in a dry, clean state.
1, 2 Tank interstitial sensor functional test not accomplished (Required annually.). - Annual leak detection testing shall be performed and passing results entered on OSFM portal.
1 Tank interstitial sensors in alarm or failed test, must repair or replace. - ATG is in alarm L13 High Liquid Alarm. Repair shall be made so ATG is not in alarm.

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 20000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/23/2004 Abandoned Material:
Current Age: 21 Abandoned Date:
Install Date: 4/16/2004 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 10/29/2025 10/29/2026
Leak Detect - Piping Electronic Pressurized Line Leak Detection 10/29/2025 10/29/2026
Leak Detect - Tank Hydrostatic Reservoir Interstitial Monitoring Sensors with monitor 10/29/2025 10/29/2026
Overfill Prev Device Overfill Drop Tube Valve 9/18/2024 9/18/2027
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 9/18/2024 9/18/2027
Leak Detect - Piping Non-Discriminating Sump Sensor 5/3/2021 5/3/2022
Leak Detect - Piping Discriminating Sump Sensor 3/17/2022 3/17/2023
Leak Detect - Piping Sump Sensor with positive shutdown 10/29/2025 10/29/2026
Piping Single Wall Transition Sump 9/18/2024 9/18/2027
Leak Detect - Piping Sump Sensor with positive shutdown 10/29/2025 10/29/2026
Piping Single Wall Transition Sump 9/18/2024 9/18/2027
Leak Detect - Piping Sump Sensor with positive shutdown 10/29/2025 10/29/2026
Piping Single Wall Transition Sump 9/18/2024 9/18/2027
Leak Detect - Piping Sump Sensor with positive shutdown 10/29/2025 10/29/2026
Piping Single Wall Transition Sump 9/18/2024 9/18/2027
Leak Detect - Piping Sump Sensor with positive shutdown 10/29/2025 10/29/2026
Piping Single Wall Transition Sump 9/18/2024 9/18/2027
Leak Detect - Piping Sump Sensor with positive shutdown 10/29/2025 10/29/2026
Spill Contain Device Single Wall Spill Bucket 9/18/2024 9/18/2027
Tank Fiberglass Brine Filled Double Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 6/15/2022



Tank Number 2

Capacity: 15000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/23/2004 Abandoned Material:
Current Age: 21 Abandoned Date:
Install Date: 4/16/2004 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 10/29/2025 10/29/2026
Leak Detect - Piping Electronic Pressurized Line Leak Detection 10/29/2025 10/29/2026
Leak Detect - Tank Hydrostatic Reservoir Interstitial Monitoring Sensors with monitor 10/29/2025 10/29/2026
Overfill Prev Device Overfill Drop Tube Valve 9/18/2024 9/18/2027
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 9/18/2024 9/18/2027
Leak Detect - Piping Non-Discriminating Sump Sensor 3/17/2022 3/17/2023
Leak Detect - Piping Sump Sensor with positive shutdown 10/29/2025 10/29/2026
Piping Single Wall Transition Sump 9/18/2024 9/18/2027
Leak Detect - Piping Sump Sensor with positive shutdown 10/29/2025 10/29/2026
Piping Single Wall Transition Sump 9/18/2024 9/18/2027
Leak Detect - Piping Sump Sensor with positive shutdown 10/29/2025 10/29/2026
Piping Single Wall Transition Sump 9/18/2024 9/18/2027
Leak Detect - Piping Sump Sensor with positive shutdown 10/29/2025 10/29/2026
Piping Single Wall Transition Sump 9/18/2024 9/18/2027
Leak Detect - Piping Sump Sensor with positive shutdown 10/29/2025 10/29/2026
Piping Single Wall Transition Sump 9/18/2024 9/18/2027
Leak Detect - Piping Sump Sensor with positive shutdown 10/29/2025 10/29/2026
Spill Contain Device Single Wall Spill Bucket 9/18/2024 9/18/2027
Tank Fiberglass Brine Filled Double Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 6/15/2022

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 9/18/2024 9/18/2027
Leak Detect - Piping Sump Sensor with positive shutdown 10/29/2025 10/29/2026



Name\ID 11/12

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 9/18/2024 9/18/2027
Leak Detect - Piping Sump Sensor with positive shutdown 10/29/2025 10/29/2026



Name\ID 13/14

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 9/18/2024 9/18/2027
Leak Detect - Piping Sump Sensor with positive shutdown 10/29/2025 10/29/2026



Name\ID 15/16

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 9/18/2024 9/18/2027
Leak Detect - Piping Sump Sensor with positive shutdown 10/29/2025 10/29/2026



Name\ID 17/18

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 9/18/2024 9/18/2027
Leak Detect - Piping Sump Sensor with positive shutdown 10/29/2025 10/29/2026



Name\ID 19/20

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 9/18/2024 9/18/2027
Leak Detect - Piping Sump Sensor with positive shutdown 10/29/2025 10/29/2026



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 9/18/2024 9/18/2027
Leak Detect - Piping Sump Sensor with positive shutdown 10/29/2025 10/29/2026



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 9/18/2024 9/18/2027
Leak Detect - Piping Sump Sensor with positive shutdown 10/29/2025 10/29/2026



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 9/18/2024 9/18/2027
Leak Detect - Piping Sump Sensor with positive shutdown 10/29/2025 10/29/2026



Name\ID 9/10

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 9/18/2024 9/18/2027
Leak Detect - Piping Sump Sensor with positive shutdown 10/29/2025 10/29/2026

MFD Motorfuel Dispensing Forms

No Forms Found