Facility Number: 2041824
Status: Active
Facility Name: BP Gas and Food, Inc.
Address: 2200 W. Galena Blvd. Aurora, IL 60504
County: Kane
Property Parcel: 15-19-180-008
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Y003354
Green Tag Issue Date: 11/14/2023
Green Tag Expiration Date: 12/31/2025

Owner Details

Owner Name: Galena Real Estate, LLC
Owner Address: 401 Hawkcrest Circle Sacramento, CA 95835
Owner Status: Current Owner
Purchase Date: 4/20/2021
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 2/25/2024

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 3/21/2023 12/31/2025

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0040400 Galena Real Estate, LLC Current Owner 4/20/2021
U0035073 Galena Gasoline, Inc. Former Owner 10/21/2008
U0000552 BP Products North America, Inc. Former Owner 11/7/2003

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violatlions (Current)

NOV Number: E0020252763 (Pending)    Issue Date: 10/20/2025    Expiration Date: 12/19/2025    View NOV Form

Tanks Violations
1, 2 Annual electronic line leak detector test not completed. - Line leak detectors need annual testing. Testing shall be performed and passing results entered on OSFM portal.
Facility Annual Emergency Stop Inspection not completed or inspection report not available. - Emergency shut off switch needs annual testing performed. OSFM form shall be kept on site.
1, 2 Annual leak detection certification not completed (Required annually). - Annual leak detection testing shall be performed and passing results entered on OSFM portal.
1, 2 Document that emergency shut-off (shear valves) are in proper working order - Shear valves need annual testing performed. OSFM form shall be completed and kept on site.
Facility Financial responsibility must be reported yearly - Section 176.220 Proof of Financial Responsibility a) Proof of financial responsibility for Section 176.215(a), (b), (c), (d) or (e) shall be maintained on the respective OSFM forms, which may be complemented by industry customs and practices so long as the OSFM form language is utilized. The forms are available at https://sfm.illinois.gov/about/divisions/petroleumchemical- safety/applications-and-forms.html
1, 2 Line interstitial sensor functional test not accomplished (Required annually). - STP, UDC, and Transition sumps need annual sensor testing. All sensors shall be tested with passing results entered on OSFM portal. STP and UDC sump sensors need annual testing performed. Passing results shall be entered on OSFM portal.
2 Line interstitial sensors have been raised and rendered inoperational. - Premium STP sump sensor is raised. 175.640 a) 2) All new and existing sump sensors must be installed so as to detect liquid per manufacturer's specifications or, if not specified by the manufacturer, at the lowest point in the sump.
1 Miscellaneous - Probe or tank sensor well needs lid secured properly.
Facility Missing copies of Annual Walkthrough Inspection Report. - Annual walkthrough needs to be performed. OSFM form shall be completed and kept on site.
1, 2 Piping interstitial must be open in all sumps - 175.420 b) Unless otherwise required by the manufacturer, the dispenser product piping sump jumper tubes shall be removed, or the product piping test boots pulled back after testing to allow the interstice to be open to the sump sensors. This is for all sumps.
1, 2 Spill prevention equipment contains liquid/debris and must be cleared of materials and maintained clean and dry. - 175.405 a) 1) A) Spill containment equipment that will prevent release of product to the environment when the transfer hose is detached from the fill pipe (e.g., a spill catch basin). Spill containment equipment shall be maintained in a dry, clean state.
1, 2 Tank interstitial sensor functional test not accomplished (Required annually.). - Annual leak detection testing shall be performed and passing results entered on OSFM portal.
1 Tank interstitial sensors in alarm or failed test, must repair or replace. - ATG is in alarm L13 High Liquid Alarm. Repair shall be made so ATG is not in alarm.

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information

Tank Number Capacity Product Status Regulated Status Red Tag Issued Fee Due Abandon/Removal Date
1 20000 Gasoline - Regular Currently in use Federal $0.00
2 15000 Gasoline - Premium Currently in use Federal $0.00

Dispenser Information

Name\ID Status
1/2 Active
11/12 Active
13/14 Active
15/16 Active
17/18 Active
19/20 Active
3/4 Active
5/6 Active
7/8 Active
9/10 Active

MFD Motorfuel Dispensing Forms

No Forms Found