Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2040463
Status: Active
Facility Name: Circle K #6827
Address: 1127 North Eola Road
Aurora, IL 60504
County: Kane
Property Parcel:
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Y002817
Green Tag Issue Date: 2/7/2024
Green Tag Expiration Date: 12/31/2025

Owner Details

Owner Name: RDK Ventures, LLC
Owner Address: 1120 W. Warner Rd.
Tempe, AZ 85284
Owner Status: Current Owner
Purchase Date: 11/7/2011
Type of Financial Responsibility: Guarantee
Financial Responsibility Reporting Due Date: 10/24/2025

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 2/7/2024 12/31/2025

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0035671 RDK Ventures, LLC Current Owner 11/7/2011
U0033589 Jewel Food Stores, Inc. Former Owner
U0028677 Albertson's, Inc. Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

NOV Number: E0020250725 (Pending)    Issue Date: 3/19/2025    Expiration Date: 5/18/2025    View NOV Form

Tanks Violation
Facility Farthest dispenser is greater than 40' and site lacks a communication system or system is inoperable - 175.210 h)The attendant shall at all times be able to communicate with persons in the dispensing area. Repair or replace intercom.

NOV Number: E0020250726 (Pending)    Issue Date: 3/19/2025    Expiration Date: 5/18/2025    View NOV Form

Tanks Violation
Facility Annual Emergency Stop Inspection not completed or inspection report not available. - Emergency shut off switch needs annual testing performed. OSFM form shall be kept on site.
2 Containment support components are cracked, deteriorated or missing. The cover and supporting components that are defective shall be replaced with factory manufactured components. - Top steel lid rim support is deteriorated and broken. This needs to be repaired or replaced so lid does not fall into sump.
1, 2 Document that emergency shut-off (shear valves) are in proper working order - Shear valves need annual testing performed. OSFM form shall be completed and kept on site.
Facility Miscellaneous - Emergency shut off switch at control station needs a sign install. 175.210 d) 3) Equipped with an emergency stop at all control stations, which shall be conspicuously marked and readily accessible to the attendant, whether or not the control station is less than 20 feet from any dispenser or a security booth is provided for the attendant. The emergency stop shall be located in a position to allow all dispensing devices to be readily visible to the attendant, or as approved by OSFM. Each emergency stop shall be identified by a sign on all-weather materials stating "EMERGENCY STOP" in 2 inch red capital letters.
Facility Missing copies of Annual Walkthrough Inspection Report. - Annual walkthrough needs to be performed. OSFM form shall be completed and kept on site.
1, 2 Piping interstitial must be open in all sumps - 175.420 b) Unless otherwise required by the manufacturer, the dispenser product piping sump jumper tubes shall be removed or the product piping test boots pulled back after testing to allow the interstice to be open to the sump sensors. This is for all sumps.

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 15000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 9/28/2001 Abandoned Material:
Current Age: 23 Abandoned Date:
Install Date: 7/9/2001 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 9/7/2001

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 10/28/2024 10/28/2025
Leak Detect - Tank Hydrostatic Reservoir Interstitial Monitoring Sensors with monitor 10/28/2024 10/28/2025
Overfill Prev Device Overfill Alarm 11/17/2022 11/17/2025
Overfill Prev Device Overfill Drop Tube Valve 11/6/2023 11/6/2026
Piping Flexible Double Wall Environ Geo Flex N/A N/A
Piping Single Wall STP/Tanktop Sump 3/29/2024 3/29/2027
Leak Detect - Piping Sump Sensor 10/28/2024 10/28/2025
Spill Contain Device Double Wall Spill Bucket 11/6/2023 11/6/2026
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Environ Geo Flex Precision Test (Piping) Pass 10/28/2024



Tank Number 2

Capacity: 10000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 9/28/2001 Abandoned Material:
Current Age: 23 Abandoned Date:
Install Date: 7/9/2001 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 9/7/2001

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 10/28/2024 10/28/2025
Leak Detect - Tank Hydrostatic Reservoir Interstitial Monitoring Sensors with monitor 10/28/2024 10/28/2025
Overfill Prev Device Overfill Alarm 11/17/2022 11/17/2025
Overfill Prev Device Overfill Drop Tube Valve 11/6/2023 11/6/2026
Piping Flexible Double Wall Environ Geo Flex N/A N/A
Piping Single Wall STP/Tanktop Sump 3/29/2024 3/29/2027
Leak Detect - Piping Sump Sensor 10/28/2024 10/28/2025
Spill Contain Device Double Wall Spill Bucket 11/6/2023 11/6/2026
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Environ Geo Flex Precision Test (Piping) Pass 10/28/2024



Tank Number 3

Capacity: 10000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Does Not Exist CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: Abandoned Material:
Current Age: Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/29/2024 3/29/2027
Leak Detect - Piping Sump Sensor 10/28/2024 10/28/2025



Name\ID 11/12

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/29/2024 3/29/2027
Leak Detect - Piping Sump Sensor 10/28/2024 10/28/2025



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/29/2024 3/29/2027
Leak Detect - Piping Sump Sensor 10/28/2024 10/28/2025



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/29/2024 3/29/2027
Leak Detect - Piping Sump Sensor 10/28/2024 10/28/2025



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/29/2024 3/29/2027
Leak Detect - Piping Sump Sensor 10/28/2024 10/28/2025



Name\ID 9/10

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/29/2024 3/29/2027
Leak Detect - Piping Sump Sensor 10/28/2024 10/28/2025

MFD Motorfuel Dispensing Forms

No Forms Found