Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2040413
Status: Active
Facility Name: Circle K #6830
Address: 1352 U.S. Route 12
Fox Lake, IL 60020
County: Lake
Property Parcel:
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Y001227
Green Tag Issue Date: 3/30/2023
Green Tag Expiration Date: 12/31/2025

Owner Details

Owner Name: RDK Ventures, LLC
Owner Address: 1120 W. Warner Rd.
Tempe, AZ 85284
Owner Status: Current Owner
Purchase Date: 11/7/2011
Type of Financial Responsibility: Guarantee
Financial Responsibility Reporting Due Date: 10/24/2025

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 12/21/2022 12/31/2025

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0035671 RDK Ventures, LLC Current Owner 11/7/2011
U0033591 ASP Realty, Inc. Former Owner 1/2/2006
U0028677 Albertson's, Inc. Former Owner 9/1/2001

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 15000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 12/21/2001 Abandoned Material:
Current Age: 23 Abandoned Date:
Install Date: 9/21/2001 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 11/28/2001

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 11/18/2024 11/18/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350R with CSLD 11/18/2024 11/18/2025
Leak Detect - Tank Hydrostatic Reservoir Interstitial Monitoring Sensors 11/18/2024 11/18/2025
Overfill Prev Device Ball Only Removed Ball Float Vent Valve N/A N/A
Overfill Prev Device Overfill Alarm 1/9/2023 1/9/2026
Overfill Prev Device Overfill Drop Tube Valve 1/23/2023 1/23/2026
Piping Polyethylene Chase N/A N/A
Piping Flexible Double Wall OPW Flexworks N/A N/A
Piping Single Wall STP/Tanktop Sump 6/4/2024 6/4/2027
Leak Detect - Piping Non-Discriminating Sump Sensor 2/8/2021 2/8/2022
Leak Detect - Piping Sump Sensor with positive shutdown 11/18/2024 11/18/2025
Spill Contain Device Double Wall Spill Bucket 12/11/2023 12/11/2026
Tank Fiberglass Brine Filled Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Environ Geo Flex Precision Test (Piping) Pass 2/8/2021
Piping Flexible Double Wall OPW Flexworks Precision Test (Piping) Pass 11/18/2024
Piping Polyethylene Chase Precision Test (Piping) Pass 11/18/2024
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors Sensor Functional Pass 9/16/2009



Tank Number 2

Capacity: 10000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 12/21/2001 Abandoned Material:
Current Age: 23 Abandoned Date:
Install Date: 9/21/2001 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 11/28/2001

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 11/18/2024 11/18/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350R with CSLD 11/18/2024 11/18/2025
Leak Detect - Tank Hydrostatic Reservoir Interstitial Monitoring Sensors 11/18/2024 11/18/2025
Overfill Prev Device Ball Only Removed Ball Float Vent Valve N/A N/A
Overfill Prev Device Overfill Alarm 1/9/2023 1/9/2026
Overfill Prev Device Overfill Drop Tube Valve 1/9/2023 1/9/2026
Piping Polyethylene Chase N/A N/A
Piping Flexible Double Wall OPW Flexworks N/A N/A
Piping Single Wall STP/Tanktop Sump 6/4/2024 6/4/2027
Leak Detect - Piping Non-Discriminating Sump Sensor 2/8/2021 2/8/2022
Leak Detect - Piping Sump Sensor with positive shutdown 11/18/2024 11/18/2025
Spill Contain Device Single Wall Spill Bucket 12/11/2023 12/11/2026
Tank Fiberglass Brine Filled Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Environ Geo Flex Precision Test (Piping) Pass 2/8/2021
Piping Flexible Double Wall OPW Flexworks Precision Test (Piping) Pass 11/18/2024
Piping Polyethylene Chase Precision Test (Piping) Pass 11/18/2024
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors Sensor Functional Pass 9/16/2009

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/4/2024 6/4/2027
Leak Detect - Piping Sump Sensor with positive shutdown 11/18/2024 11/18/2025



Name\ID 11/12

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/4/2024 6/4/2027
Leak Detect - Piping Sump Sensor with positive shutdown 11/18/2024 11/18/2025



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/4/2024 6/4/2027
Leak Detect - Piping Sump Sensor with positive shutdown 11/18/2024 11/18/2025



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/4/2024 6/4/2027
Leak Detect - Piping Sump Sensor with positive shutdown 11/18/2024 11/18/2025



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/4/2024 6/4/2027
Leak Detect - Piping Sump Sensor with positive shutdown 11/18/2024 11/18/2025



Name\ID 9/10

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/4/2024 6/4/2027
Leak Detect - Piping Sump Sensor with positive shutdown 11/18/2024 11/18/2025

MFD Motorfuel Dispensing Forms

No Forms Found