Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2040402
Status: Active
Facility Name: Equinix, Inc.
Address: 350 East Cermak
Chicago, IL 60616
County: Cook
Property Parcel:
Facility Type: Commercial / Retail
Owner Type: Private
Green Tag Decal: Z002155
Green Tag Issue Date: 2/6/2024
Green Tag Expiration Date: 12/31/2026

Owner Details

Owner Name: Equinix, Inc.
Owner Address: 1 Lagoon Drive
Redwood City, CA 94065
Owner Status: Current Owner
Purchase Date:
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 8/27/2025

Motor Fuel Dispensing Permits

No MFD Permits Found

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0029579 Equinix, Inc. Current Owner
U0030052 Verio, Inc. Former Owner 10/19/2000

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 8500 Petroleum Use: Back-up Generator
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 2/21/2001 Abandoned Material:
Current Age: 24 Abandoned Date:
Install Date: 10/19/2000 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 10/20/2000

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 12/19/2024 12/19/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 12/19/2024 12/19/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 12/19/2024 12/19/2025
Overfill Prev Device Overfill Alarm 1/26/2023 1/26/2026
Overfill Prev Device Overfill Drop Tube Valve 1/26/2023 1/26/2026
Piping Fiberglass Chase N/A N/A
Piping Steel Chase N/A N/A
Piping Single Wall STP/Tanktop Sump 1/26/2023 1/26/2026
Leak Detect - Piping Sump Sensor 12/19/2024 12/19/2025
Spill Contain Device Single Wall Spill Bucket 1/26/2023 1/26/2026
Tank Composite Double Wall ACT 100 N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Chase Precision Test (Piping) Pass 12/19/2024
Tank Composite Double Wall ACT 100 Precision Test (Tank) Pass 11/13/2020



Tank Number 2

Capacity: 15000 Petroleum Use: Back-up Generator
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 9/22/2000 Abandoned Material:
Current Age: 24 Abandoned Date:
Install Date: 6/3/2000 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 7/3/2000

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Other Non-vented check valve N/A N/A
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 12/19/2024 12/19/2025
Leak Detect - Tank Hydrostatic Reservoir Interstitial Monitoring Sensors 12/19/2024 12/19/2025
Overfill Prev Device Overfill Alarm 1/26/2023 1/26/2026
Overfill Prev Device Overfill Drop Tube Valve 1/26/2023 1/26/2026
Piping Fiberglass Chase N/A N/A
Piping Steel Chase N/A N/A
Piping Single Wall STP/Tanktop Sump 1/26/2023 1/26/2026
Leak Detect - Piping Sump Sensor 12/19/2024 12/19/2025
Spill Contain Device Single Wall Spill Bucket 1/26/2023 1/26/2026
Tank Composite Double Wall Modern Welding Glasteel II N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Chase Precision Test (Piping) Pass 12/19/2024



Tank Number 3

Capacity: 15000 Petroleum Use: Back-up Generator
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 9/22/2000 Abandoned Material:
Current Age: 24 Abandoned Date:
Install Date: 6/3/2000 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 6/3/2000

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Other Non-vented check valve N/A N/A
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 12/19/2024 12/19/2025
Leak Detect - Tank Hydrostatic Reservoir Interstitial Monitoring Sensors 12/19/2024 12/19/2025
Overfill Prev Device Overfill Alarm 1/26/2023 1/26/2026
Overfill Prev Device Overfill Drop Tube Valve 1/26/2023 1/26/2026
Piping Fiberglass Chase N/A N/A
Piping Steel Chase N/A N/A
Piping Single Wall STP/Tanktop Sump 1/26/2023 1/26/2026
Leak Detect - Piping Sump Sensor 12/19/2024 12/19/2025
Spill Contain Device Single Wall Spill Bucket 1/26/2023 1/26/2026
Tank Composite Double Wall Modern Welding Glasteel II N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Chase Precision Test (Piping) Pass 12/19/2024

Dispenser Information



MFD Motorfuel Dispensing Forms

No Forms Found