Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2040285
Status: Active
Facility Name: Will County Division of Transportation
Address: 1240 Caton Farm Road Crest Hill, IL 60435
County: Will
Property Parcel: 11-04-33-100-006
Facility Type: County
Owner Type: County
Green Tag Decal: AA04301
Green Tag Issue Date: 8/7/2025
Green Tag Expiration Date: 12/31/2027

Owner Details

Owner Name: Will County Division of Transportation
Owner Address: 16841 West Laraway Road Joliet, IL 60433
Owner Status: Current Owner
Purchase Date:
Type of Financial Responsibility: Self-Insurance
Financial Responsibility Reporting Due Date: 8/31/2026

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Fleet 8/7/2025 12/31/2027

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0016414 Will County Division of Transportation Current Owner

Permits (Unexpired)

Click for permit history
Permit Number Type Status OSFM Receive Date Issue Date Expiration Date Documents
00518-2025INS Install Approved / Issued 4/30/2025 4/30/2025 10/30/2025 Documents
00515-2025REM Removal Approved / Issued 4/30/2025 4/30/2025 10/30/2025 Documents

Notice of Violatlions (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
2025-0473 6/25/2025 Removal Log 00515-2025REM

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
20250473 Eligible 8/13/2025 8/19/2025 $5,000 Letter
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 10000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 6/25/2025
OSFM First Notify Date: 12/26/2001 Abandoned Material:
Current Age: 24 Abandoned Date:
Install Date: 5/20/2001 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 3/12/2024 3/12/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 3/12/2024 3/12/2025
Overfill Prev Device Overfill Drop Tube Valve 9/20/2024 9/20/2027
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Flex Connector Steel N/A N/A
Piping Single Wall STP/Tanktop Sump 9/20/2024 9/20/2027
Leak Detect - Piping Non-Discriminating Sump Sensor 3/27/2023 3/27/2024
Leak Detect - Piping Sump Sensor with positive shutdown 3/12/2024 3/12/2025
Spill Contain Device Single Wall Spill Bucket 9/20/2024 9/20/2027
Tank Fiberglass Double Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 3/12/2024



Tank Number 2

Capacity: 10000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 6/25/2025
OSFM First Notify Date: 12/26/2001 Abandoned Material:
Current Age: 24 Abandoned Date:
Install Date: 5/24/2001 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 3/12/2024 3/12/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 3/12/2024 3/12/2025
Overfill Prev Device Overfill Drop Tube Valve 9/20/2024 9/20/2027
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Flex Connector Steel N/A N/A
Piping Single Wall STP/Tanktop Sump 9/20/2024 9/20/2027
Leak Detect - Piping Non-Discriminating Sump Sensor 3/27/2023 3/27/2024
Leak Detect - Piping Sump Sensor with positive shutdown 3/12/2024 3/12/2025
Spill Contain Device Single Wall Spill Bucket 9/20/2024 9/20/2027
Tank Fiberglass Double Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 3/12/2024



Tank Number 3

Capacity: 10000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 8/4/2025 Abandoned Material:
Current Age: 0 Abandoned Date:
Install Date: 7/2/2025 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 7/31/2025

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 8/4/2025 8/4/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 8/4/2025 8/4/2026
Overfill Prev Device Overfill Alarm 8/4/2025 8/4/2028
Overfill Prev Device Overfill Drop Tube Valve 8/4/2025 8/4/2028
Piping Flexible Double Wall A.P.T. Poly Tech N/A N/A
Piping Single Wall STP/Tanktop Sump 7/10/2025 7/10/2028
Leak Detect - Piping Sump Sensor with positive shutdown 8/4/2025 8/4/2026
Spill Contain Device Double Wall Spill Bucket 7/10/2025 7/10/2028
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall A.P.T. Poly Tech Precision Test (Piping) Pass 8/4/2025
Tank Fiberglass Double Wall XERXES Precision Test (Tank) Pass 8/4/2025



Tank Number 4

Capacity: 10000 Petroleum Use: None
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 8/4/2025 Abandoned Material:
Current Age: 0 Abandoned Date:
Install Date: 7/2/2025 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 7/31/2025

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 8/4/2025 8/4/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 8/4/2025 8/4/2026
Overfill Prev Device Overfill Alarm 8/4/2025 8/4/2028
Overfill Prev Device Overfill Drop Tube Valve 8/4/2025 8/4/2028
Piping Flexible Double Wall A.P.T. Poly Tech N/A N/A
Piping Single Wall STP/Tanktop Sump 7/10/2025 7/10/2028
Leak Detect - Piping Sump Sensor with positive shutdown 8/4/2025 8/4/2026
Spill Contain Device Double Wall Spill Bucket 7/10/2025 7/10/2028
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall A.P.T. Poly Tech Precision Test (Piping) Pass 8/4/2025
Tank Fiberglass Double Wall XERXES Precision Test (Tank) Pass 8/4/2025

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 7/10/2025 7/10/2028
Leak Detect - Piping Sump Sensor with positive shutdown 8/4/2025 8/4/2026



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 7/10/2025 7/10/2028
Leak Detect - Piping Sump Sensor with positive shutdown 8/4/2025 8/4/2026

MFD Motorfuel Dispensing Forms

No Forms Found