Information
JB Pritzker, Governor
Michele L Pankow, State Fire Marshal
Division of Petroleum & Chemical Safety
State of Illinois
Employment Opportunities
Ready Illinois
Find us on Facebook
UST
Search
Contractor Search
Permit Search
Disclaimer & Rules/Statutes
Disclaimer
Rules
Statutes
Statistics & Reports
Statistics
Red Tag Tanks
Blended Fuel Tanks
Federal Energy Act Reports
Help
Division of Petroleum & Chemical Safety
Facility Details
Facility Number:
2039831
Status:
Closed
Facility Name:
Chicagoland Speedway #0493-2802
Address:
500 Speedway Blvd. Joliet, IL 60433
County:
Will
Property Parcel:
30-07-34-400-008-0000
Facility Type:
Private Institution
Owner Type:
Private
Green Tag Decal:
U001781
Green Tag Issue Date:
1/27/2020
Green Tag Expiration Date:
12/31/2021
Owner Details
Owner Name:
Sunoco, LLC
Owner Address:
1815 Gallagher Rd. Plymouth Meeting, PA 19462
Owner Status:
Current Owner
Purchase Date:
6/1/2014
Type of Financial Responsibility:
Commercial Insurance
Financial Responsibility Reporting Due Date:
9/30/2026
Motor Fuel Dispensing Permits
MFD Permit Type
Issue Date
Expiration Date
Fleet
10/29/2019
12/31/2021
Owner Summary
Click for Facility/Tank Ownership history
Owner Number
Owner Name
Owner Status
Purchase Date
U0037871
Sunoco, LLC
Current Owner
6/1/2014
U0039706
Sunoco, LLC
Former Owner
6/1/2014
U0037871
Sunoco, LLC
Former Owner
6/1/2014
U0030824
Phillips 66
Former Owner
1/1/2004
U0031863
Sunoco, Inc.
Former Owner
U0029565
Tosco Corporation
Former Owner
Permits (Unexpired)
Click for permit history
Permit Number
Type
Status
OSFM Receive Date
Issue Date
Expiration Date
Documents
01566-2025REM
Removal
Approved / Issued
11/20/2025
11/21/2025
5/21/2026
Documents
Notice of Violatlions (Current)
No Notice of Violations Found
IEMA Numbers Associated with the Facility
No IEMA Numbers Found
LUST
Fund Eligibility and Deductibility Determinations
No Applications Found
Pay Tank Fees Online
Tank Information
Tank Number 1
Capacity:
15000
Petroleum Use:
Product:
Racing Fuel
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
12/17/2025
OSFM
First Notify Date:
5/15/2001
Abandoned Material:
Current Age:
24
Abandoned Date:
Install Date:
10/6/2000
Red Tag Issue Date:
Last Used Date:
3/30/2021
Fee Due:
$0.00
Product Date:
4/27/2001
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Fiberglass Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Fiberglass Non-Corrosive
N/A
N/A
Leak Detect - Piping
Mechanical Pressurized Line Leak Detection
6/19/2020
6/19/2021
Leak Detect - Tank
Automatic Tank Gauging Veeder Root TLS 350 Plus
6/19/2020
6/19/2021
Leak Detect - Tank
Non-Discriminating Interstitial Monitoring Sensors
6/19/2020
6/19/2021
Overfill Prev Device
Overfill Drop Tube Valve
8/31/2020
8/31/2023
Piping
Fiberglass Double Wall A.O. Smith
N/A
N/A
Piping
Single Wall STP/Tanktop Sump
7/28/2017
7/28/2020
Leak Detect - Piping
Sump Sensor
6/19/2020
6/19/2021
Spill Contain Device
Single Wall Spill Bucket
7/15/2019
7/15/2022
Tank
Fiberglass Double Wall XERXES
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Piping
Fiberglass Double Wall A.O. Smith
Precision Test (Piping)
Pass
6/19/2020
Dispenser Information
Name\ID 1/2
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
Leak Detect - Piping
Piping Sump Sensors Not Regulated Not Required
N/A
N/A
Name\ID 3/4
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
Leak Detect - Piping
Piping Sump Sensors Not Regulated Not Required
N/A
N/A
MFD
Motorfuel Dispensing Forms
No Forms Found