Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2039335
Status: Active
Facility Name: Speedway #1417
Address: 4032 Route 34 Oswego, IL 60543
County: Kendall
Property Parcel: 03-17-280-002
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Y002816
Green Tag Issue Date: 2/7/2024
Green Tag Expiration Date: 12/31/2025

Owner Details

Owner Name: Speedway, LLC
Owner Address: P.O. Box 1500 Springfield, OH 45501
Owner Status: Current Owner
Purchase Date: 5/13/2011
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 12/13/2025

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 2/7/2024 12/31/2025

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0026552 Speedway, LLC Current Owner 5/13/2011
U0005658 Gas City, Ltd. Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violatlions (Current)

NOV Number: E0020251822 (Pending)    Issue Date: 7/15/2025    Expiration Date: 9/13/2025    View NOV Form

Tanks Violations
Facility Miscellaneous - Emergency shut off switch between dispensers 13/14 rquires a new sign.

NOV Number: E0020251823 (Pending)    Issue Date: 7/15/2025    Expiration Date: 9/13/2025    View NOV Form

Tanks Violations
1, 5 Install or replace lockable fill pipe caps. - Tank # 1 regular Northwest and Tank # 5 E85 require new fill caps since existing caps are broken.
5 Miscellaneous - Tank 5 E85 is missing vapor cap.
1, 2, 3, 4, 5, 6 Spill prevention equipment contains liquid/debris and must be cleared of materials and maintained clean and dry. - 175.405 a) 1) A) Spill containment equipment that will prevent release of product to the environment when the transfer hose is detached from the fill pipe (e.g., a spill catch basin). Spill containment equipment shall be maintained in a dry, clean state.

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
00-0347 3/1/2000 Removal Log 00245-2000REM

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 12000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 7/12/2000 Abandoned Material:
Current Age: 25 Abandoned Date:
Install Date: 4/7/2000 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 4/7/2000

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 6/25/2025 6/25/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 6/25/2025 6/25/2026
Overfill Prev Device Overfill Drop Tube Valve 7/26/2023 7/26/2026
Overfill Prev Device Overfill Drop Tube Valve 7/26/2023 7/26/2026
Piping Flexible Double Wall Environ Geo Flex N/A N/A
Piping Single Wall STP/Tanktop Sump 6/2/2024 6/2/2027
Leak Detect - Piping Sump Sensor 6/25/2025 6/25/2026
Spill Contain Device Single Wall Spill Bucket 6/2/2024 6/2/2027
Spill Contain Device Single Wall Spill Bucket 6/2/2024 6/2/2027
Tank Composite Double Wall Modern Welding Glasteel II N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 8000 Petroleum Use:
Product: Gasoline - Mid-grade CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 7/12/2000 Abandoned Material:
Current Age: 25 Abandoned Date:
Install Date: 4/7/2000 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 4/7/2000

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 6/25/2025 6/25/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 6/25/2025 6/25/2026
Overfill Prev Device Overfill Drop Tube Valve 7/26/2023 7/26/2026
Piping Flexible Double Wall Environ Geo Flex N/A N/A
Piping Single Wall STP/Tanktop Sump 6/2/2024 6/2/2027
Leak Detect - Piping Sump Sensor 6/25/2025 6/25/2026
Spill Contain Device Single Wall Spill Bucket 6/2/2024 6/2/2027
Tank Composite Double Wall Modern Welding Glasteel II N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 8000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 7/12/2000 Abandoned Material:
Current Age: 25 Abandoned Date:
Install Date: 4/7/2000 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 4/7/2000

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 6/25/2025 6/25/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 6/25/2025 6/25/2026
Overfill Prev Device Overfill Drop Tube Valve 7/26/2023 7/26/2026
Piping Flexible Double Wall Environ Geo Flex N/A N/A
Piping Single Wall STP/Tanktop Sump 6/2/2024 6/2/2027
Leak Detect - Piping Sump Sensor 6/25/2025 6/25/2026
Spill Contain Device Single Wall Spill Bucket 6/2/2024 6/2/2027
Tank Composite Double Wall Modern Welding Glasteel II N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 4

Capacity: 8000 Petroleum Use:
Product: B-11 CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 7/12/2000 Abandoned Material:
Current Age: 25 Abandoned Date:
Install Date: 4/7/2000 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 4/7/2000

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 6/25/2025 6/25/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 6/25/2025 6/25/2026
Overfill Prev Device Overfill Drop Tube Valve 7/26/2023 7/26/2026
Piping Flexible Double Wall Environ Geo Flex N/A N/A
Piping Single Wall STP/Tanktop Sump 6/2/2024 6/2/2027
Leak Detect - Piping Sump Sensor 6/25/2025 6/25/2026
Spill Contain Device Single Wall Spill Bucket 6/2/2024 6/2/2027
Tank Composite Double Wall Modern Welding Glasteel II N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 5

Capacity: 2000 Petroleum Use:
Product: E85 CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 7/12/2000 Abandoned Material:
Current Age: 25 Abandoned Date:
Install Date: 4/7/2000 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 4/7/2000

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 6/25/2025 6/25/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 6/25/2025 6/25/2026
Overfill Prev Device Overfill Drop Tube Valve 7/26/2023 7/26/2026
Piping Flexible Double Wall Environ Geo Flex N/A N/A
Piping Single Wall STP/Tanktop Sump 6/2/2024 6/2/2027
Leak Detect - Piping Sump Sensor 6/25/2025 6/25/2026
Spill Contain Device Single Wall Spill Bucket 6/2/2024 6/2/2027
Tank Composite Double Wall Modern Welding Glasteel II N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 6

Capacity: 2000 Petroleum Use:
Product: Kerosene CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 7/12/2000 Abandoned Material:
Current Age: 25 Abandoned Date:
Install Date: 4/7/2000 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 4/7/2000

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 6/25/2025 6/25/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 6/25/2025 6/25/2026
Overfill Prev Device Overfill Drop Tube Valve 7/26/2023 7/26/2026
Piping Flexible Double Wall Environ Geo Flex N/A N/A
Piping Single Wall STP/Tanktop Sump 6/2/2024 6/2/2027
Leak Detect - Piping Sump Sensor 6/25/2025 6/25/2026
Spill Contain Device Single Wall Spill Bucket 6/2/2024 6/2/2027
Tank Composite Double Wall Modern Welding Glasteel II N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 7

Capacity: 550 Petroleum Use:
Product: Heating Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: State Removed Date: 3/1/2000
OSFM First Notify Date: 4/24/2000 Abandoned Material:
Current Age: Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 12/31/1973 Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/2/2024 6/2/2027
Leak Detect - Piping Sump Sensor with positive shutdown 6/25/2025 6/25/2026



Name\ID 11/12

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/2/2024 6/2/2027
Leak Detect - Piping Sump Sensor with positive shutdown 6/25/2025 6/25/2026



Name\ID 13

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/2/2024 6/2/2027
Leak Detect - Piping Sump Sensor with positive shutdown 6/25/2025 6/25/2026



Name\ID 14

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/2/2024 6/2/2027
Leak Detect - Piping Sump Sensor with positive shutdown 6/25/2025 6/25/2026



Name\ID 15

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/2/2024 6/2/2027
Leak Detect - Piping Sump Sensor with positive shutdown 6/25/2025 6/25/2026



Name\ID 16

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/2/2024 6/2/2027
Leak Detect - Piping Sump Sensor with positive shutdown 6/25/2025 6/25/2026



Name\ID 17

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/2/2024 6/2/2027
Leak Detect - Piping Sump Sensor with positive shutdown 6/25/2025 6/25/2026



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/2/2024 6/2/2027
Leak Detect - Piping Sump Sensor with positive shutdown 6/25/2025 6/25/2026



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/2/2024 6/2/2027
Leak Detect - Piping Sump Sensor with positive shutdown 6/25/2025 6/25/2026



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/2/2024 6/2/2027
Leak Detect - Piping Sump Sensor with positive shutdown 6/25/2025 6/25/2026



Name\ID 9/10

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/2/2024 6/2/2027
Leak Detect - Piping Sump Sensor with positive shutdown 6/25/2025 6/25/2026

MFD Motorfuel Dispensing Forms

No Forms Found