Owner Summary
Click for Facility/Tank Ownership history
| Owner Number |
Owner Name |
Owner Status |
Purchase Date |
| U0041771 |
MC Huntley Real Estate, Inc. |
Current Owner |
1/9/2026 |
| U0028842 |
Drendel Enterprises LLC |
Former Owner |
|
Notice of Violations (Current)
No Notice of Violations Found
IEMA Numbers Associated with the Facility
No IEMA Numbers Found
LUST
Fund Eligibility and Deductibility Determinations
No Applications Found
Tank Number 1
| Capacity: |
15000 |
|
Petroleum Use: |
|
| Product: |
Gasoline - Premium |
|
CERCLA Substance: |
|
| Status: |
Currently in use |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
|
|
OSFM
First Notify Date: |
8/1/2000 |
|
Abandoned Material: |
|
| Current Age: |
25 |
|
Abandoned Date: |
|
| Install Date: |
11/3/1999 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
7/26/2000 |
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Flexible Non-Corrosive |
Not applicable |
Not applicable |
|
Corrosion Prot - Tank
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Leak Detect - Piping
|
Mechanical Pressurized Line Leak Detection |
9/15/2025 |
9/15/2026 |
|
Leak Detect - Tank
|
Hydrostatic Reservoir Interstitial Monitoring Sensors with monitor |
9/15/2025 |
9/15/2026 |
|
Overfill Prev Device
|
Overfill Drop Tube Valve |
2/9/2024 |
2/9/2027 |
|
Piping
|
Flexible Double Wall Environ Geo Flex |
Not applicable |
Not applicable |
|
Piping
|
Single Wall STP/Tanktop Sump |
9/9/2024 |
9/9/2027 |
Leak Detect - Piping
|
Sump Sensor |
9/9/2024 |
9/9/2027 |
|
Spill Contain Device
|
Double Wall Spill Bucket |
2/9/2024 |
2/9/2027 |
|
Tank
|
Fiberglass Double Wall Fluid Containment Brine Filled |
Not applicable |
Not applicable |
Additional Tests
| Equipment Type |
Equipment |
Test Type |
Test Result |
Test Date |
|
Piping
|
Flexible Double Wall Environ Geo Flex
|
Precision Test (Piping)
|
Pass
|
9/15/2025
|
|
Tank
|
Fiberglass Double Wall Fluid Containment Brine Filled
|
Precision Test (Tank)
|
Pass
|
2/12/2024
|
Tank Number 2
| Capacity: |
20000 |
|
Petroleum Use: |
|
| Product: |
Gasoline - Regular |
|
CERCLA Substance: |
|
| Status: |
Currently in use |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
|
|
OSFM
First Notify Date: |
8/1/2000 |
|
Abandoned Material: |
|
| Current Age: |
25 |
|
Abandoned Date: |
|
| Install Date: |
11/3/1999 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
7/26/2000 |
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Flexible Non-Corrosive |
Not applicable |
Not applicable |
|
Corrosion Prot - Tank
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Leak Detect - Piping
|
Mechanical Pressurized Line Leak Detection |
9/15/2025 |
9/15/2026 |
|
Leak Detect - Tank
|
Hydrostatic Reservoir Interstitial Monitoring Sensors with monitor |
9/15/2025 |
9/15/2026 |
|
Overfill Prev Device
|
Overfill Drop Tube Valve |
2/9/2024 |
2/9/2027 |
|
Piping
|
Flexible Double Wall Environ Geo Flex |
Not applicable |
Not applicable |
|
Piping
|
Single Wall STP/Tanktop Sump |
9/9/2024 |
9/9/2027 |
Leak Detect - Piping
|
Sump Sensor |
9/9/2024 |
9/9/2027 |
|
Spill Contain Device
|
Double Wall Spill Bucket |
2/9/2024 |
2/9/2027 |
|
Tank
|
Fiberglass Double Wall Fluid Containment Brine Filled |
Not applicable |
Not applicable |
Additional Tests
| Equipment Type |
Equipment |
Test Type |
Test Result |
Test Date |
|
Piping
|
Flexible Double Wall Environ Geo Flex
|
Precision Test (Piping)
|
Pass
|
9/15/2025
|
|
Tank
|
Fiberglass Double Wall Fluid Containment Brine Filled
|
Precision Test (Tank)
|
Pass
|
3/3/2023
|
Failed test = the latest test has failed.
Not applicable = a test does not apply to this equipment type or configuration.
No passing test found = a passing test is expected but was not found from the source data.
MFD
Motorfuel Dispensing Forms
No Forms Found