Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2038979
Status: Active
Facility Name: PB Food Mart, Inc.
Address: 2000 N. Harlem Avenue
Elmwood Park, IL 60707
County: Cook
Property Parcel: 12-36-231-029-0000
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Y002001
Green Tag Issue Date: 7/26/2023
Green Tag Expiration Date: 12/31/2025

Owner Details

Owner Name: PB Real Estate Enterprises, Inc.
Owner Address: 2000 N. Harlem Avenue
Elmwood Park, IL 60707
Owner Status: Current Owner
Purchase Date: 5/4/2022
Type of Financial Responsibility: Designated Savings Account
Financial Responsibility Reporting Due Date: 1/21/2026

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 5/23/2023 12/31/2025

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0040847 PB Real Estate Enterprises, Inc. Current Owner 5/4/2022
U0032000 2000 N. Harlem, L.L.C. Former Owner 1/1/2002
U0032414 Jaquar, Inc. Former Owner
U0028774 Bill Reichardt Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

NOV Number: E0020250843 (Pending)    Issue Date: 4/1/2025    Expiration Date: 5/31/2025    View NOV Form

Tanks Violation
Facility Annual Emergency Stop Inspection not completed or inspection report not available.
Facility Facility Operation and Maintenance Plan not completed or available.
7 Miscellaneous - Sump sensor must remain in vertical position
Facility Missing copies of 30 day Walkthrough Inspection Report.
Facility Missing copies of Annual Walkthrough Inspection Report.
6, 7 Overfill alarm does not appear to function properly.
6, 7 Shear valve inspection report not completed (Required during Annual Walkthrough Inspection).
6, 7 Spill prevention equipment contains liquid/debris and must be cleared of materials and maintained clean and dry.

NOV Number: E0020250844 (Pending)    Issue Date: 4/1/2025    Expiration Date: 5/31/2025    View NOV Form

Tanks Violation
Facility Farthest dispenser is greater than 40' and site lacks a communication system or system is inoperable

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
99-2317 10/12/1999 Removal Log 02455-1999REM

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 500 Petroleum Use:
Product: Hazardous Substance CERCLA Substance: Trichloro Ethylene
Status: Removed CAS Code: 79016
Regulated Status: Exempt Removed Date: 10/12/1999
OSFM First Notify Date: 10/21/1999 Abandoned Material:
Current Age: Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 12/31/1973 Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 1000 Petroleum Use:
Product: Hazardous Substance CERCLA Substance: Trichloro Ethylene
Status: Removed CAS Code: 79016
Regulated Status: Exempt Removed Date: 10/12/1999
OSFM First Notify Date: 10/21/1999 Abandoned Material:
Current Age: Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 12/31/1973 Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 1000 Petroleum Use:
Product: Hazardous Substance CERCLA Substance: Trichloro Ethylene
Status: Removed CAS Code: 79016
Regulated Status: Exempt Removed Date: 10/12/1999
OSFM First Notify Date: 10/21/1999 Abandoned Material:
Current Age: Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 12/31/1973 Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 4

Capacity: 2000 Petroleum Use:
Product: Hazardous Substance CERCLA Substance: Trichloro Ethylene
Status: Removed CAS Code: 79016
Regulated Status: Exempt Removed Date: 10/12/1999
OSFM First Notify Date: 10/21/1999 Abandoned Material:
Current Age: Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 12/31/1973 Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 5

Capacity: 5000 Petroleum Use:
Product: Hazardous Substance CERCLA Substance: Trichloro Ethylene
Status: Removed CAS Code: 79016
Regulated Status: Exempt Removed Date: 10/12/1999
OSFM First Notify Date: 10/21/1999 Abandoned Material:
Current Age: Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 12/31/1973 Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 6

Capacity: 10000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 11/3/2004 Abandoned Material:
Current Age: 21 Abandoned Date:
Install Date: 8/6/2002 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 5/12/2004

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 10/29/2024 10/29/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 300i 10/29/2024 10/29/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 10/29/2024 10/29/2025
Overfill Prev Device Overfill Alarm 4/18/2023 4/18/2026
Overfill Prev Device Overfill Drop Tube Valve 6/22/2023 6/22/2026
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 4/18/2023 4/18/2026
Leak Detect - Piping Non-Discriminating Sump Sensor 11/10/2020 11/10/2021
Leak Detect - Piping Sump Sensor with positive shutdown 10/29/2024 10/29/2025
Spill Contain Device Double Wall Spill Bucket 6/22/2023 6/22/2026
Tank Composite Double Wall Modern Welding Glasteel II N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 10/29/2024
Piping Flexible Double Wall Precision Test (Piping) Pass 10/19/2022
Tank Composite Double Wall Modern Welding Glasteel II Precision Test (Tank) Pass 12/19/2019



Tank Number 7

Capacity: 12000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 11/3/2004 Abandoned Material:
Current Age: 21 Abandoned Date:
Install Date: 8/6/2002 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 5/12/2004

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 10/29/2024 10/29/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 300i 10/29/2024 10/29/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 10/29/2024 10/29/2025
Overfill Prev Device Overfill Alarm 4/18/2023 4/18/2026
Overfill Prev Device Overfill Drop Tube Valve 4/18/2023 4/18/2026
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 4/18/2023 4/18/2026
Leak Detect - Piping Non-Discriminating Sump Sensor 11/10/2020 11/10/2021
Leak Detect - Piping Sump Sensor with positive shutdown 10/29/2024 10/29/2025
Spill Contain Device Single Wall Spill Bucket 4/18/2023 4/18/2026
Tank Composite Double Wall Modern Welding Glasteel II N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 10/29/2024
Piping Flexible Double Wall Precision Test (Piping) Pass 10/19/2022
Tank Composite Double Wall Modern Welding Glasteel II Precision Test (Tank) Pass 8/3/2021

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/18/2023 4/18/2026
Leak Detect - Piping Sump Sensor with positive shutdown 10/29/2024 10/29/2025



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/18/2023 4/18/2026
Leak Detect - Piping Sump Sensor with positive shutdown 10/29/2024 10/29/2025



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/18/2023 4/18/2026
Leak Detect - Piping Sump Sensor with positive shutdown 10/29/2024 10/29/2025



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/18/2023 4/18/2026
Leak Detect - Piping Sump Sensor with positive shutdown 10/29/2024 10/29/2025

MFD Motorfuel Dispensing Forms