Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2038367
Status: Active
Facility Name: Wood Dale Oil Co., Inc. d/b/a Thorndale Shell
Address: 1001 Wood Dale Road
Wood Dale, IL 60191
County: Du Page
Property Parcel: 03-04-401-005
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: X003247
Green Tag Issue Date: 11/3/2022
Green Tag Expiration Date: 12/31/2024

Owner Details

Owner Name: Wood Dale Oil Co., LLC
Owner Address: 5300 W. Touhy Ave.
Skokie, IL 60007
Owner Status: Current Owner / Operator
Purchase Date:
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 4/5/2025

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 11/2/2022 12/31/2024

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0028418 Wood Dale Oil Co., LLC Current Owner / Operator
U0026641 Lockhani Navroz Former Owner / Operator

Permits (Unexpired)

Click for permit history

No Active Permits Found

Deficiencies (Current)

NOV Number: E0020240410 (Pending)    Issue Date: 2/14/2024    Expiration Date: 4/14/2024    View NOV Form

Tanks Deficiency
Facility Financial responsibility must be reported yearly - The Notification Form is available at: https://webapps.sfm.illinois.gov/USTPortal/NotificationForm. This form is required to be submitted within 30 days of an ownership change.

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 20000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 9/8/1999 Abandoned Material:
Current Age: 24 Abandoned Date:
Install Date: 5/1/1999 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 9/6/2023 9/6/2024
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 9/6/2023 9/6/2024
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 9/6/2023 9/6/2024
Overfill Prev Device Overfill Drop Tube Valve 11/3/2022 11/3/2025
Piping Fiberglass Double Wall N/A N/A
Piping Single Wall STP/Tanktop Sump 10/19/2020 10/19/2023
Leak Detect - Piping Sump Sensor 9/6/2023 9/6/2024
Spill Contain Device Single Wall Spill Bucket 9/25/2021 9/25/2024
Tank Composite Double Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Precision Test Pass 9/26/2020



Tank Number 2

Capacity: 20000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 9/8/1999 Abandoned Material:
Current Age: 24 Abandoned Date:
Install Date: 5/1/1999 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 9/6/2023 9/6/2024
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 9/6/2023 9/6/2024
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 9/6/2023 9/6/2024
Overfill Prev Device Overfill Drop Tube Valve 11/3/2022 11/3/2025
Piping Fiberglass Double Wall N/A N/A
Piping Single Wall STP/Tanktop Sump 1/12/2021 1/12/2024
Leak Detect - Piping Sump Sensor 9/6/2023 9/6/2024
Spill Contain Device Single Wall Spill Bucket 9/25/2021 9/25/2024
Tank Composite Double Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Precision Test Pass 9/26/2020



Tank Number 3

Capacity: 15000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 9/8/1999 Abandoned Material:
Current Age: 24 Abandoned Date:
Install Date: 5/1/1999 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 5/1/1999

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 9/6/2023 9/6/2024
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 9/6/2023 9/6/2024
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 10/9/2023 10/9/2024
Overfill Prev Device Overfill Drop Tube Valve 9/17/2022 9/17/2025
Piping Fiberglass Double Wall N/A N/A
Piping Single Wall STP/Tanktop Sump 10/19/2020 10/19/2023
Leak Detect - Piping Sump Sensor 9/6/2023 9/6/2024
Spill Contain Device Single Wall Spill Bucket 9/25/2021 9/25/2024
Tank Composite Double Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Precision Test Pass 9/26/2020



Tank Number 4

Capacity: 15000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 6/3/2004 Abandoned Material:
Current Age: 19 Abandoned Date:
Install Date: 10/7/2003 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 5/24/2004

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 9/6/2023 9/6/2024
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 9/6/2023 9/6/2024
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 9/6/2023 9/6/2024
Overfill Prev Device Ball Float Vent Valve OPW 53VM 9/17/2022 9/17/2025
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 10/19/2020 10/19/2023
Leak Detect - Piping Sump Sensor 9/6/2023 9/6/2024
Spill Contain Device Single Wall Spill Bucket 9/25/2021 9/25/2024
Tank Composite Double Wall Glasteel II N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test Pass 9/26/2020

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 10/19/2020 10/19/2023
Leak Detect - Piping Sump Sensor 9/6/2023 9/6/2024



Name\ID 11/12

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 10/19/2020 10/19/2023
Leak Detect - Piping Sump Sensor with positive shutdown 9/6/2023 9/6/2024



Name\ID 13/14

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 1/12/2021 1/12/2024
Leak Detect - Piping Sump Sensor 9/6/2023 9/6/2024



Name\ID 15/16

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 10/19/2020 10/19/2023
Leak Detect - Piping Sump Sensor 9/6/2023 9/6/2024



Name\ID 17/18

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 10/19/2020 10/19/2023
Leak Detect - Piping Sump Sensor 9/6/2023 9/6/2024



Name\ID 19/20

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 10/19/2020 10/19/2023
Leak Detect - Piping Sump Sensor 9/6/2023 9/6/2024



Name\ID 21/22

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 1/12/2021 1/12/2024
Leak Detect - Piping Sump Sensor 9/6/2023 9/6/2024



Name\ID 23/24

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 10/19/2020 10/19/2023
Leak Detect - Piping Sump Sensor 9/6/2023 9/6/2024



Name\ID 25/26S

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 10/19/2020 10/19/2023
Leak Detect - Piping Sump Sensor with positive shutdown 9/6/2023 9/6/2024



Name\ID 25S

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 10/19/2020 10/19/2023
Leak Detect - Piping Sump Sensor with positive shutdown 9/6/2023 9/6/2024



Name\ID 26/27S

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 10/19/2020 10/19/2023
Leak Detect - Piping Sump Sensor with positive shutdown 9/6/2023 9/6/2024



Name\ID 27/28S

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 10/19/2020 10/19/2023
Leak Detect - Piping Sump Sensor with positive shutdown 9/6/2023 9/6/2024



Name\ID 28

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 10/19/2020 10/19/2023
Leak Detect - Piping Sump Sensor with positive shutdown 9/6/2023 9/6/2024



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 10/19/2020 10/19/2023
Leak Detect - Piping Sump Sensor with positive shutdown 9/6/2023 9/6/2024



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 1/12/2021 1/12/2024
Leak Detect - Piping Sump Sensor 9/6/2023 9/6/2024



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 1/12/2021 1/12/2024
Leak Detect - Piping Sump Sensor 9/6/2023 9/6/2024



Name\ID 9/10

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 10/19/2020 10/19/2023
Leak Detect - Piping Sump Sensor 9/6/2023 9/6/2024

MFD Motorfuel Dispensing Forms