Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2038109
Status: Active
Facility Name: Lucky Place, Inc.
Address: 3780 West Lincoln Highway
Olympia Fields, IL 60461
County: Cook
Property Parcel: 31-23-107-054-0000
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Y002490
Green Tag Issue Date: 6/23/2023
Green Tag Expiration Date: 12/31/2025

Owner Details

Owner Name: Lucky Place, Inc.
Owner Address: 3780 Lincoln Hwy
Olympia Fields, IL 60461
Owner Status: Current Owner
Purchase Date: 7/15/2021
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 2/3/2026

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 6/23/2023 12/31/2025

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0040601 Lucky Place, Inc. Current Owner 7/15/2021
U0040533 Lucky Place, Inc. Former Owner 7/15/2021
U0018799 Unknown Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

NOV Number: E0020250253 (Pending)    Issue Date: 2/3/2025    Expiration Date: 4/4/2025    View NOV Form

Tanks Violation
Facility Facility Operation and Maintenance Plan not completed or available. - Not Completely filled out.
Facility Miscellaneous - Each emergency stop shall be identified by an approved sign on all-weather materials stating "EMERGENCY STOP" in 2 inch red capital letters. Reference 175.210 d)3)
Facility Missing copies of 30 day Walkthrough Inspection Report. - 30-day Walkthrough Inspection shall be completed, and documentation maintained on site. 30-Day Walkthrough Inspection form available at https://sfm.illinois.gov.
Facility Missing copy of emergency instructions or emergency procedures plan - Needs to be completely filled out.
7, 8, 9 Monthly line interstitial sensor records not available. - Maintain one NORMAL report per LINE, per month, from ATG. (Liquid Status)
7, 8, 9 Piping interstitial must be open in all sumps - Product piping sump jumper tubes shall be removed or the product piping test boots pulled back after testing to allow the interstice to be open to the sump sensors. 175.420 b) (STPs and Dispesners)
7, 8, 9 Required monthly tank interstitial sensor records not available. - Maintain one NORMAL report per TANK, per month, from ATG. (Liquid Status)
7, 8, 9 Required monthly tank leak test records not available. - Maintain one PASSING report per TANK, per month, from ATG. Reference 175.630 c)2)B)

NOV Number: E0020250254 (Pending)    Issue Date: 2/3/2025    Expiration Date: 4/4/2025    View NOV Form

Tanks Violation
Facility Farthest dispenser is greater than 40' and site lacks a communication system or system is inoperable - Intercom system not functional; repair/replace as necessary to provide communication at dispensers. Reference 175.210 h)
Facility Fire Extinguishers - Past due for annual testing - June of 2024 is when testing was required.

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 500 Petroleum Use: None
Product: Used Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 3/10/1999
OSFM First Notify Date: 3/25/1999 Abandoned Material:
Current Age: Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 4000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 3/10/1999
OSFM First Notify Date: 3/25/1999 Abandoned Material:
Current Age: Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 4000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 3/10/1999
OSFM First Notify Date: 3/25/1999 Abandoned Material:
Current Age: Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 4

Capacity: 10000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 3/10/1999
OSFM First Notify Date: 11/23/1998 Abandoned Material:
Current Age: Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 5

Capacity: 4000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 3/10/1999
OSFM First Notify Date: 11/23/1998 Abandoned Material:
Current Age: Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 6

Capacity: 500 Petroleum Use:
Product: Used Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 3/10/1999
OSFM First Notify Date: 11/23/1998 Abandoned Material:
Current Age: Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 7

Capacity: 6000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 6/9/2023 Abandoned Material:
Current Age: 1 Abandoned Date:
Install Date: 10/14/2022 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 5/12/2023

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 9/19/2024 9/19/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 Plus 9/19/2024 9/19/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 9/19/2024 9/19/2025
Overfill Prev Device Overfill Alarm 6/20/2023 6/20/2026
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 6/20/2023 6/20/2026
Leak Detect - Piping Sump Sensor with positive shutdown 9/19/2024 9/19/2025
Spill Contain Device Single Wall Spill Bucket 6/20/2023 6/20/2026
Tank Fiberglass Double Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 9/19/2024
Tank Fiberglass Double Wall Precision Test (Tank) Pass 9/19/2024



Tank Number 8

Capacity: 18000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 6/9/2023 Abandoned Material:
Current Age: 1 Abandoned Date:
Install Date: 10/14/2022 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 5/12/2023

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 9/19/2024 9/19/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 Plus 9/19/2024 9/19/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 9/19/2024 9/19/2025
Overfill Prev Device Overfill Alarm 6/20/2023 6/20/2026
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 6/20/2023 6/20/2026
Leak Detect - Piping Sump Sensor with positive shutdown 9/19/2024 9/19/2025
Spill Contain Device Single Wall Spill Bucket 6/20/2023 6/20/2026
Tank Fiberglass Double Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 9/19/2024
Tank Fiberglass Double Wall Precision Test (Tank) Pass 9/19/2024



Tank Number 9

Capacity: 6000 Petroleum Use: None
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 6/9/2023 Abandoned Material:
Current Age: 1 Abandoned Date:
Install Date: 10/14/2022 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 5/12/2023

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 9/19/2024 9/19/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 Plus 9/19/2024 9/19/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 9/19/2024 9/19/2025
Overfill Prev Device Overfill Alarm 6/20/2023 6/20/2026
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 6/20/2023 6/20/2026
Leak Detect - Piping Sump Sensor with positive shutdown 9/19/2024 9/19/2025
Spill Contain Device Single Wall Spill Bucket 6/20/2023 6/20/2026
Tank Fiberglass Double Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 9/19/2024
Tank Fiberglass Double Wall Precision Test (Tank) Pass 9/19/2024

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/20/2023 6/20/2026
Leak Detect - Piping Sump Sensor with positive shutdown 9/19/2024 9/19/2025



Name\ID 11/12

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/20/2023 6/20/2026
Leak Detect - Piping Sump Sensor with positive shutdown 9/19/2024 9/19/2025



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/20/2023 6/20/2026
Leak Detect - Piping Sump Sensor with positive shutdown 9/19/2024 9/19/2025



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/20/2023 6/20/2026
Leak Detect - Piping Sump Sensor with positive shutdown 9/19/2024 9/19/2025



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/20/2023 6/20/2026
Leak Detect - Piping Sump Sensor with positive shutdown 9/19/2024 9/19/2025



Name\ID 9/10

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/20/2023 6/20/2026
Leak Detect - Piping Sump Sensor with positive shutdown 9/19/2024 9/19/2025

MFD Motorfuel Dispensing Forms

Facility Number Name City Received Date Letter
2038109 Lucky Place, Inc. Olympia Fields 06/12/2023 Letter Form