Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2037431
Status: Inactive
Facility Name: Imperial Realty Group, LLC
Address: 16635 Crawford Avenue Markham, IL 60428
County: Cook
Property Parcel: 28-23-300-012-0000
Facility Type: Private Institution
Owner Type: Private
Green Tag Decal: X000967
Green Tag Issue Date: 1/4/2023
Green Tag Expiration Date: 12/31/2024

Owner Details

Owner Name: Imperial Realty Group, LLC
Owner Address: 16635 Crawford Avenue Markham, IL 60428
Owner Status: Current Owner
Purchase Date: 8/5/2021
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 2/15/2026

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Fleet 1/4/2023 12/31/2024

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0040518 Imperial Realty Group, LLC Current Owner 8/5/2021
U0027723 Morehouse Cartage Inc Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violatlions (Current)

NOV Number: E0020252111 (Pending)    Issue Date: 8/14/2025    Expiration Date: 10/13/2025    View NOV Form

Tanks Violations
1 Remove tank(s) - Single-Walled, Over 30 Years Old and OOS Over One Year - Last used was 7/3/2023.

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 8000 Petroleum Use: None
Product: Diesel Fuel CERCLA Substance:
Status: Out of service CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 9/29/1998 Abandoned Material:
Current Age: Abandoned Date:
Install Date: Red Tag Issue Date: 6/5/2024
Last Used Date: 7/3/2023 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping European with No Test Req Suction N/A N/A
Leak Detect - Tank Automatic Tank Gauging EBW Auto-Stik Jr. 12/15/2022 12/15/2023
Overfill Prev Device Overfill Drop Tube Valve 6/4/2024 6/4/2027
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 5/7/2020 5/7/2023
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A

MFD Motorfuel Dispensing Forms

No Forms Found