Facility Details
Facility Number:
2036635
Status:
Active
Facility Name:
Circle K #6876
Address:
596 S. Montgomery
Montgomery, IL 60538
County:
Kane
Property Parcel:
15-34-259-014
Facility Type:
Attended Self-Service Station
Owner Type:
Private
Green Tag Decal:
AA01567
Green Tag Issue Date:
5/14/2025
Green Tag Expiration Date:
12/31/2027
Owner Details
Owner Name:
RDK Ventures, LLC
Owner Address:
1120 W. Warner Rd.
Tempe, AZ 85284
Owner Status:
Current Owner
Purchase Date:
12/11/2014
Type of Financial Responsibility:
Guarantee
Financial Responsibility Reporting Due Date:
10/24/2025
Motor Fuel Dispensing Permits
MFD Permit Type
Issue Date
Expiration Date
Self Service
5/14/2025
12/31/2027
Owner Summary
Click for Facility/Tank Ownership history
Owner Number
Owner Name
Owner Status
Purchase Date
U0035671
RDK Ventures, LLC
Current Owner
12/11/2014
U0031954
Gas Mart USA, Inc.
Former Owner
2/13/2004
U0031087
Conoco Phillips
Former Owner
1/1/2003
U0026814
Chase Manhattan Rlty Leasing Corp
Former Owner
9/8/1998
U0011862
Phillips Petroleum Co
Former Owner
Permits (Unexpired)
Click for permit history
Permit Number
Type
Status
OSFM Receive Date
Issue Date
Expiration Date
Documents
00024-2025UPG
Upgrade
Approved / Issued
1/8/2025
1/8/2025
7/8/2025
Documents
Notice of Violations (Current)
No Notice of Violations Found
IEMA Numbers Associated with the Facility
No IEMA Numbers Found
LUST
Fund Eligibility and Deductibility Determinations
IEMA Number
Status
OSFM Received Date
OSFM Response Date
Deductible
Letter
20220982
Eligible
1/23/2023
1/30/2023
$5,000
Letter
Pay Tank Fees Online
Tank Information
Tank Number 1
Capacity:
12000
Petroleum Use:
Product:
Gasoline - Regular
CERCLA Substance:
Status:
Currently in use
CAS Code:
Regulated Status:
Federal
Removed Date:
OSFM
First Notify Date:
11/9/1998
Abandoned Material:
Current Age:
26
Abandoned Date:
Install Date:
9/8/1998
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
9/8/1998
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Flexible Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Fiberglass Non-Corrosive
N/A
N/A
Leak Detect - Piping
Electronic Pressurized Line Leak Detection
7/29/2024
7/29/2025
Leak Detect - Tank
Automatic Tank Gauging Veeder Root TLS 350R with CSLD
7/29/2024
7/29/2025
Overfill Prev Device
Overfill Drop Tube Valve
7/29/2024
7/29/2027
Piping
Flexible Double Wall Total Containment Omniflex I
N/A
N/A
Piping
Single Wall STP/Tanktop Sump
7/30/2024
7/30/2027
Leak Detect - Piping
Sump Sensor with positive shutdown
7/29/2024
7/29/2025
Spill Contain Device
Double Wall Spill Bucket
7/29/2024
7/29/2027
Tank
Fiberglass Single Wall XERXES
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Piping
Flexible Double Wall Total Containment Omniflex I
Precision Test (Piping)
Pass
7/29/2024
Tank
Fiberglass Single Wall XERXES
Precision Test (Tank)
Pass
10/23/2019
Tank Number 2
Capacity:
12000
Petroleum Use:
Product:
Gasoline - Regular
CERCLA Substance:
Status:
Currently in use
CAS Code:
Regulated Status:
Federal
Removed Date:
OSFM
First Notify Date:
11/9/1998
Abandoned Material:
Current Age:
26
Abandoned Date:
Install Date:
9/8/1998
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
9/8/1998
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Flexible Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Fiberglass Non-Corrosive
N/A
N/A
Leak Detect - Piping
Mechanical Other Non-vented check valve
N/A
N/A
Leak Detect - Tank
Automatic Tank Gauging Veeder Root TLS 350R with CSLD
7/29/2024
7/29/2025
Overfill Prev Device
Overfill Drop Tube Valve
2/17/2025
2/17/2028
Piping
Flexible Double Wall Total Containment Omniflex I
N/A
N/A
Piping
Single Wall STP/Tanktop Sump
7/30/2024
7/30/2027
Leak Detect - Piping
Sump Sensor with positive shutdown
7/29/2024
7/29/2025
Spill Contain Device
Double Wall Spill Bucket
1/23/2025
1/23/2028
Tank
Fiberglass Single Wall XERXES
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Piping
Flexible Double Wall Total Containment Omniflex I
Precision Test (Piping)
Pass
7/29/2024
Tank
Fiberglass Single Wall XERXES
Precision Test (Tank)
Pass
10/23/2019
Tank Number 3
Capacity:
12000
Petroleum Use:
Product:
Gasoline - Premium
CERCLA Substance:
Status:
Currently in use
CAS Code:
Regulated Status:
Federal
Removed Date:
OSFM
First Notify Date:
11/9/1998
Abandoned Material:
Current Age:
26
Abandoned Date:
Install Date:
9/8/1998
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
9/8/1998
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Flexible Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Fiberglass Non-Corrosive
N/A
N/A
Leak Detect - Piping
Electronic Pressurized Line Leak Detection
7/29/2024
7/29/2025
Leak Detect - Tank
Automatic Tank Gauging Veeder Root TLS 350R with CSLD
7/29/2024
7/29/2025
Overfill Prev Device
Overfill Drop Tube Valve
2/17/2025
2/17/2028
Piping
Flexible Double Wall Total Containment Omniflex I
N/A
N/A
Piping
Single Wall STP/Tanktop Sump
7/30/2024
7/30/2027
Leak Detect - Piping
Sump Sensor with positive shutdown
7/29/2024
7/29/2025
Spill Contain Device
Single Wall Spill Bucket
2/17/2025
2/17/2028
Tank
Fiberglass Single Wall XERXES
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Piping
Flexible Double Wall Total Containment Omniflex I
Precision Test (Piping)
Pass
7/29/2024
Tank
Fiberglass Single Wall XERXES
Precision Test (Tank)
Pass
12/5/2024
Dispenser Information
Name\ID 1/2
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
7/30/2024
7/30/2027
Leak Detect - Piping
Sump Sensor with positive shutdown
7/29/2024
7/29/2025
Name\ID 11/12
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
7/30/2024
7/30/2027
Leak Detect - Piping
Sump Sensor with positive shutdown
7/29/2024
7/29/2025
Name\ID 13/14
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
7/30/2024
7/30/2027
Leak Detect - Piping
Sump Sensor with positive shutdown
7/29/2024
7/29/2025
Name\ID 15/16
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
7/30/2024
7/30/2027
Leak Detect - Piping
Sump Sensor with positive shutdown
7/29/2024
7/29/2025
Name\ID 3/4
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
7/30/2024
7/30/2027
Leak Detect - Piping
Sump Sensor with positive shutdown
7/29/2024
7/29/2025
Name\ID 5/6
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
7/30/2024
7/30/2027
Leak Detect - Piping
Sump Sensor with positive shutdown
7/29/2024
7/29/2025
Name\ID 7/8
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
11/12/2024
11/12/2027
Leak Detect - Piping
Sump Sensor with positive shutdown
7/29/2024
7/29/2025
Name\ID 9/10
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
7/30/2024
7/30/2027
Leak Detect - Piping
Sump Sensor with positive shutdown
7/29/2024
7/29/2025
MFD
Motorfuel Dispensing Forms
No Forms Found