Notice of Violations (Current)
NOV Number:
E0020260486
(Referred to Legal)
Issue Date:
2/24/2026
Expiration Date:
4/25/2026
View NOV Form
| Tanks |
Violations |
| 1 |
Containment support components are cracked, deteriorated or missing. The cover and supporting components that are defective shall be replaced with factory manufactured components. - Sump lid is caving in, must be replaced. North most tank.
Containments shall have a factory manufactured protective cover and supporting components that are
properly maintained. Reference 175.410 a)
The other two are still ok but will be need to be replaced soon. |
| Facility |
Financial responsibility must be reported yearly - Financial Responsibility must be declared annually. The form can be found at: https://webapps.sfm.illinois.gov/USTPortal/Forms/FinancialResponsibility. |
| Facility |
Submit Notification Form for Ownership Change - Must provide a proof of ownership. We need a copy of the current deed. The county website has conflicting information. |
NOV Number:
E0020261239
(Pending)
Issue Date:
5/11/2026
Expiration Date:
7/10/2026
View NOV Form
| Tanks |
Violations |
| 1, 2, 3 |
Annual electronic line leak detector test not completed. |
| 1, 2, 3 |
Annual leak detection certification not completed (Required annually). |
| 1 |
Line interstitial sensor functional test not accomplished (Required annually). - For dispensers 1/2, 3/4, 5/6, 7/8, 9/10, and 11/12. |
| 1 |
Line interstitial sensor functional test not accomplished (Required annually). - Tank sumps 1 and 3. |
| 2, 3 |
Line interstitial sensor functional test not accomplished (Required annually). - For dispensers 1/2, 3/4, 5/6, 7/8, 9/10, and 11/12. |
| 3 |
Line interstitial sensor functional test not accomplished (Required annually). - Tank sumps 1 and 3. |
| 1, 2, 3 |
Tank interstitial sensor functional test not accomplished (Required annually). |
IEMA Numbers Associated with the Facility
No IEMA Numbers Found
LUST
Fund Eligibility and Deductibility Determinations
No Applications Found
Tank Number 1
| Capacity: |
12000 |
|
Petroleum Use: |
|
| Product: |
Gasoline - Regular |
|
CERCLA Substance: |
|
| Status: |
Currently in use |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
|
|
OSFM
First Notify Date: |
12/21/1999 |
|
Abandoned Material: |
|
| Current Age: |
26 |
|
Abandoned Date: |
|
| Install Date: |
7/28/1999 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
11/30/1999 |
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Corrosion Prot - Tank
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Leak Detect - Piping
|
Electronic Pressurized Line Leak Detection |
4/29/2026 |
4/29/2027 |
|
Leak Detect - Tank
|
Automatic Tank Gauging Veeder Root TLS 350 with CSLD |
7/9/2026 |
7/9/2027 |
|
Leak Detect - Tank
|
Hydrostatic Reservoir Interstitial Monitoring Sensors |
4/29/2026 |
4/29/2027 |
|
Overfill Prev Device
|
Ball Only Removed Ball Float Vent Valve |
Not applicable |
Not applicable |
|
Overfill Prev Device
|
Overfill Alarm |
11/8/2023 |
11/8/2026 |
|
Piping
|
Fiberglass Double Wall Ameron |
Not applicable |
Not applicable |
|
Piping
|
Single Wall STP/Tanktop Sump |
11/8/2023 |
11/8/2026 |
Leak Detect - Piping
|
Sump Sensor |
11/8/2023 |
11/8/2026 |
|
Spill Contain Device
|
Single Wall Spill Bucket |
11/8/2023 |
11/8/2026 |
|
Tank
|
Fiberglass Double Wall Fluid Containment Brine Filled |
Not applicable |
Not applicable |
Additional Tests
| Equipment Type |
Equipment |
Test Type |
Test Result |
Test Date |
|
Piping
|
Fiberglass Double Wall Ameron
|
Precision Test (Piping)
|
Pass
|
9/17/2020
|
Tank Number 2
| Capacity: |
10000 |
|
Petroleum Use: |
|
| Product: |
Gasoline - Regular |
|
CERCLA Substance: |
|
| Status: |
Currently in use |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
|
|
OSFM
First Notify Date: |
12/21/1999 |
|
Abandoned Material: |
|
| Current Age: |
26 |
|
Abandoned Date: |
|
| Install Date: |
7/28/1999 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
11/30/1999 |
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Corrosion Prot - Tank
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Leak Detect - Piping
|
Electronic Pressurized Line Leak Detection |
4/29/2026 |
4/29/2027 |
|
Leak Detect - Tank
|
Automatic Tank Gauging Veeder Root TLS 350 with CSLD |
7/9/2026 |
7/9/2027 |
|
Leak Detect - Tank
|
Hydrostatic Reservoir Interstitial Monitoring Sensors |
4/29/2026 |
4/29/2027 |
|
Overfill Prev Device
|
Ball Only Removed Ball Float Vent Valve |
Not applicable |
Not applicable |
|
Overfill Prev Device
|
Overfill Alarm |
11/8/2023 |
11/8/2026 |
|
Piping
|
Fiberglass Double Wall Ameron |
Not applicable |
Not applicable |
|
Piping
|
Single Wall STP/Tanktop Sump |
3/13/2024 |
3/13/2027 |
Leak Detect - Piping
|
Sump Sensor with positive shutdown |
3/13/2024 |
3/13/2027 |
|
Spill Contain Device
|
Single Wall Spill Bucket |
11/8/2023 |
11/8/2026 |
|
Tank
|
Fiberglass Double Wall Fluid Containment Brine Filled |
Not applicable |
Not applicable |
Additional Tests
No Tests Listed
Tank Number 3
| Capacity: |
10000 |
|
Petroleum Use: |
|
| Product: |
Gasoline - Premium |
|
CERCLA Substance: |
|
| Status: |
Currently in use |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
|
|
OSFM
First Notify Date: |
12/21/1999 |
|
Abandoned Material: |
|
| Current Age: |
26 |
|
Abandoned Date: |
|
| Install Date: |
7/28/1999 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
11/30/1999 |
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Corrosion Prot - Tank
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Leak Detect - Piping
|
Electronic Pressurized Line Leak Detection |
4/29/2026 |
4/29/2027 |
|
Leak Detect - Tank
|
Automatic Tank Gauging Veeder Root TLS 350 with CSLD |
7/9/2026 |
7/9/2027 |
|
Leak Detect - Tank
|
Hydrostatic Reservoir Interstitial Monitoring Sensors |
4/29/2026 |
4/29/2027 |
|
Overfill Prev Device
|
Ball Only Removed Ball Float Vent Valve |
Not applicable |
Not applicable |
|
Overfill Prev Device
|
Overfill Alarm |
11/8/2023 |
11/8/2026 |
|
Piping
|
Fiberglass Double Wall Ameron |
Not applicable |
Not applicable |
|
Piping
|
Single Wall STP/Tanktop Sump |
11/8/2023 |
11/8/2026 |
Leak Detect - Piping
|
Sump Sensor |
11/8/2023 |
11/8/2026 |
|
Spill Contain Device
|
Single Wall Spill Bucket |
11/8/2023 |
11/8/2026 |
|
Tank
|
Fiberglass Double Wall Fluid Containment Brine Filled |
Not applicable |
Not applicable |
Additional Tests
No Tests Listed
Failed test = the latest test has failed.
Not applicable = a test does not apply to this equipment type or configuration.
No passing test found = a passing test is expected but was not found from the source data.
MFD
Motorfuel Dispensing Forms
No Forms Found