Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2035598
Status: Active
Facility Name: Halsted 844, Inc. d/b/a Midwest Gas
Address: 844 S. Halsted
Chicago Heights, IL 60411
County: Cook
Property Parcel: 32-17-424-008-0000
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Y002040
Green Tag Issue Date: 1/8/2024
Green Tag Expiration Date: 12/31/2025

Owner Details

Owner Name: HPG Holding, Inc.
Owner Address: 12346 S. Keeler Ave.
Alsip, IL 60803
Owner Status: Current Owner
Purchase Date: 3/5/2021
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 12/9/2025

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 1/8/2024 12/31/2025

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0039315 HPG Holding, Inc. Current Owner 3/5/2021
U0040108 Chicago Title Land Trust Co. Trust #11557 Former Owner 3/6/2018
U0027952 Ali, Akhtar Former Owner 12/10/1998
U0025636 Ali Akhtar Former Owner 3/10/1995
U0025636 Ali Akhtar Former Owner 3/10/1995
U0025636 Ali Akhtar Former Owner 3/10/1995
U0038057 Khan, Atlas Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

NOV Number: E0020250357 (Pending)    Issue Date: 2/11/2025    Expiration Date: 4/12/2025    View NOV Form

Tanks Violation
Facility Farthest dispenser is greater than 40' and site lacks a communication system or system is inoperable - Intercom system not functional; repair/replace as necessary to provide communication at dispensers. Reference 175.210 h)

NOV Number: E0020250358 (Pending)    Issue Date: 2/11/2025    Expiration Date: 4/12/2025    View NOV Form

Tanks Violation
Facility Annual Emergency Stop Inspection not completed or inspection report not available. - All emergency shutoff switches shall be tested annually to verify they shut down all STPs and dispensers. Perform test, complete form (form is available at https://sfm.illinois.gov) and maintain on site with other annual testing documentation.
4, 5 Annual leak detection certification not completed (Required annually). - Annual leak detection certification (ATG) not completed. Testing shall be completed and submitted to OSFM.
4, 5 Mechanical line leak detector requires annual functional test.
Facility Missing copies of 30 day Walkthrough Inspection Report. - 30-day Walkthrough Inspection shall be completed, and documentation maintained on site. 30-Day Walkthrough Inspection form available at https://sfm.illinois.gov.
Facility Missing copies of Annual Walkthrough Inspection Report. - Annual Walkthrough by a licensed contractor shall be conducted and documentation maintained on site.
Facility Missing copies of current testing certificates for operator training - Primary A / B certified operator shall be retrained as a result of NOV being issued. (Ahemd Moctar)
4, 5 Precision line test required. - Annual Precision line test past due.
4, 5 Shear valve inspection report not completed (Required during Annual Walkthrough Inspection). - Provide documentation that annual testing of all shear valves has been conducted and passed. Go to https://sfm.illinois.gov to print out the Shear Valve inspection form.
4 Spill prevention equipment contains liquid/debris and must be cleared of materials and maintained clean and dry.
4, 5 Tank monitor does not appear to function properly and requires maintenance. - Indicator light(s) on panel of Veeder-Root ATG is/are not functional. Replace as necessary to provide proper operation. (Green and Yellow)

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
99-1221 5/20/1999 Removal Log 00224-1999REM

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
99-1221 Eligible 5/1/2000 5/10/2000 $100,000
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 7500 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 5/20/1999
OSFM First Notify Date: 3/28/1997 Abandoned Material:
Current Age: 29 Abandoned Date:
Install Date: 8/2/1969 Red Tag Issue Date:
Last Used Date: 4/1/1992 Fee Due: $0.00
Product Date: 8/3/1969

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 7500 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 5/20/1999
OSFM First Notify Date: 3/28/1997 Abandoned Material:
Current Age: 29 Abandoned Date:
Install Date: 8/2/1969 Red Tag Issue Date:
Last Used Date: 4/1/1992 Fee Due: $0.00
Product Date: 8/3/1969

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 7500 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 5/20/1999
OSFM First Notify Date: 3/28/1997 Abandoned Material:
Current Age: 29 Abandoned Date:
Install Date: 8/2/1969 Red Tag Issue Date:
Last Used Date: 4/1/1992 Fee Due: $0.00
Product Date: 8/3/1969

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 4

Capacity: 10000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 7/10/2001 Abandoned Material:
Current Age: 24 Abandoned Date:
Install Date: 3/7/2000 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 6/1/2000

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 2/14/2025 2/14/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 Plus with CSLD 2/14/2025 2/14/2026
Overfill Prev Device Ball Float Vent Valve 2/26/2024 2/26/2027
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 2/26/2024 2/26/2027
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test (Piping) Pass 2/14/2025
Tank Fiberglass Single Wall Precision Test (Tank) Pass 3/18/2021



Tank Number 5

Capacity: 6000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 7/10/2001 Abandoned Material:
Current Age: 24 Abandoned Date:
Install Date: 3/7/2000 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 6/1/2000

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 2/14/2025 2/14/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 Plus with CSLD 2/14/2025 2/14/2026
Overfill Prev Device Ball Only Removed Ball Float Vent Valve N/A N/A
Overfill Prev Device Overfill Drop Tube Valve 2/26/2024 2/26/2027
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 2/26/2024 2/26/2027
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test (Piping) Pass 2/14/2025
Tank Fiberglass Single Wall Precision Test (Tank) Pass 3/18/2021



Tank Number 6

Capacity: 10000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Does Not Exist CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: Abandoned Material:
Current Age: Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection
Leak Detect - Tank Automatic Tank Gauging Incon TS 1000
Overfill Prev Device Overfill Drop Tube Valve
Piping Fiberglass Single Wall Piping Ameron N/A N/A
Spill Contain Device Single Wall Spill Bucket
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A

MFD Motorfuel Dispensing Forms