Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2035300
Status: Active
Facility Name: Shree Sudarsan BP, Inc.
Address: 2791 West Ogden Avenue
Oswego, IL 60543
County: Kendall
Property Parcel: 03-10-304-001
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Y003381
Green Tag Issue Date: 1/4/2024
Green Tag Expiration Date: 12/31/2025

Owner Details

Owner Name: Shree Sudarsan BP, Inc.
Owner Address: 2791 US Route 34
Oswego, IL 60446
Owner Status: Current Owner
Purchase Date: 5/26/2015
Type of Financial Responsibility: Certificate of Deposit
Financial Responsibility Reporting Due Date: 9/3/2025

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 1/4/2024 12/31/2025

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0037856 Shree Sudarsan BP, Inc. Current Owner 5/26/2015
U0035189 PAV 2, LLC, Former Owner 12/5/2013
U0034435 Oswego Petroleum, LLC Former Owner 10/9/2007
U0000574 Amoco Oil Company Former Owner 10/25/1996
U0000552 BP Products North America, Inc. Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

NOV Number: E0020251060 (Pending)    Issue Date: 4/17/2025    Expiration Date: 6/16/2025    View NOV Form

Tanks Violation
Facility Annual Emergency Stop Inspection not completed or inspection report not available. - Emergency shut off switch needs annual testing performed. OSFM form shall be kept on site.
1, 2, 3 Document that emergency shut-off (shear valves) are in proper working order - Shear valves need annual testing performed. OSFM form shall be completed and kept on site.
1 Miscellaneous - Vapor cap is missing.
Facility Missing copies of Annual Walkthrough Inspection Report. - Annual walkthrough needs to be performed. OSFM form shall be completed and kept on site.
1, 2, 3 Piping containment sump failed triennial testing. Repair or replace. - Dispenser 1/2 sump failed. Repair sump and retest. Passing results shall be entered on OSFM portal.
1, 2, 3 Spill prevention equipment contains liquid/debris and must be cleared of materials and maintained clean and dry. - 175.405 a) 1) A) Spill containment equipment that will prevent release of product to the environment when the transfer hose is detached from the fill pipe (e.g., a spill catch basin). Spill containment equipment shall be maintained in a dry, clean state.
2, 3 Triennial testing for qualifying piping containment sump not completed (Required every 3 years). - STP sumps need triannual testing. Passing results shall be entered on OSFM portal.

NOV Number: E0020251061 (Pending)    Issue Date: 4/17/2025    Expiration Date: 6/16/2025    View NOV Form

Tanks Violation
Facility Farthest dispenser is greater than 40' and site lacks a communication system or system is inoperable - 175.210 h)The attendant shall at all times be able to communicate with persons in the dispensing area. Repair or replace intercom.

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 10000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 3/27/1997 Abandoned Material:
Current Age: 28 Abandoned Date:
Install Date: 10/25/1996 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 10/25/1996

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 11/7/2024 11/7/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 11/7/2024 11/7/2025
Leak Detect - Tank Hydrostatic Reservoir Interstitial Monitoring Sensors 11/7/2024 11/7/2025
Overfill Prev Device Overfill Drop Tube Valve 12/8/2022 12/8/2025
Piping Fiberglass Double Wall A.O. Smith N/A N/A
Piping Single Wall STP/Tanktop Sump 8/10/2023 8/10/2026
Leak Detect - Piping Sump Sensor 11/7/2024 11/7/2025
Spill Contain Device Single Wall Spill Bucket 11/7/2024 11/7/2027
Tank Fiberglass Double Wall Fluid Containment Brine Filled N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall A.O. Smith Precision Test (Piping) Pass 4/10/2023
Tank Fiberglass Double Wall Fluid Containment Brine Filled Precision Test (Tank) Pass 4/10/2023



Tank Number 2

Capacity: 10000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 3/27/1997 Abandoned Material:
Current Age: 28 Abandoned Date:
Install Date: 10/25/1996 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 10/25/1996

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 11/7/2024 11/7/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 11/7/2024 11/7/2025
Leak Detect - Tank Hydrostatic Reservoir Interstitial Monitoring Sensors 11/7/2024 11/7/2025
Overfill Prev Device Overfill Drop Tube Valve 12/8/2022 12/8/2025
Piping Fiberglass Double Wall A.O. Smith N/A N/A
Piping Single Wall STP/Tanktop Sump 5/8/2025 5/8/2028
Leak Detect - Piping Sump Sensor 11/7/2024 11/7/2025
Spill Contain Device Single Wall Spill Bucket 11/7/2024 11/7/2027
Tank Fiberglass Double Wall Fluid Containment Brine Filled N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall A.O. Smith Precision Test (Piping) Pass 4/10/2023
Tank Fiberglass Double Wall Fluid Containment Brine Filled Precision Test (Tank) Pass 4/10/2023



Tank Number 3

Capacity: 10000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 3/27/1997 Abandoned Material:
Current Age: 28 Abandoned Date:
Install Date: 10/25/1996 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 10/25/1996

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 11/7/2024 11/7/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 11/7/2024 11/7/2025
Leak Detect - Tank Hydrostatic Reservoir Interstitial Monitoring Sensors 11/7/2024 11/7/2025
Overfill Prev Device Overfill Drop Tube Valve 12/8/2022 12/8/2025
Piping Fiberglass Double Wall A.O. Smith N/A N/A
Piping Single Wall STP/Tanktop Sump 5/8/2025 5/8/2028
Leak Detect - Piping Sump Sensor 11/7/2024 11/7/2025
Spill Contain Device Single Wall Spill Bucket 11/7/2024 11/7/2027
Tank Fiberglass Double Wall Fluid Containment Brine Filled N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall A.O. Smith Precision Test (Piping) Pass 4/10/2023
Tank Fiberglass Double Wall Fluid Containment Brine Filled Precision Test (Tank) Pass 4/10/2023

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/9/2021 3/6/2024
Leak Detect - Piping Sump Sensor with positive shutdown 11/7/2024 11/7/2025



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/6/2024 3/6/2027
Leak Detect - Piping Sump Sensor 11/7/2024 11/7/2025



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/6/2024 3/6/2027
Leak Detect - Piping Sump Sensor 11/7/2024 11/7/2025



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/6/2024 3/6/2027
Leak Detect - Piping Sump Sensor with positive shutdown 11/7/2024 11/7/2025

MFD Motorfuel Dispensing Forms

No Forms Found