Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2034942
Status: Closed
Facility Name: The North Shore Country Day School
Address: 310 Green Bay Rd
Winnetka, IL 600934094
County: Cook
Property Parcel:
Facility Type: Private Institution
Owner Type: Private
Green Tag Decal: K006993
Green Tag Issue Date: 7/30/2009
Green Tag Expiration Date: 12/31/2011

Owner Details

Owner Name: The North Shore Country Day School
Owner Address: 310 Green Bay Rd
Winnetka, IL 600934094
Owner Status: Current Owner
Purchase Date: 6/22/1987
Type of Financial Responsibility: Self-Insurance
Financial Responsibility Reporting Due Date: 8/31/2010

Motor Fuel Dispensing Permits

No MFD Permits Found

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0024766 The North Shore Country Day School Current Owner 6/22/1987

Permits (Unexpired)

Click for permit history

No Active Permits Found

Deficiencies (Current)

No Deficiencies Found

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
10-0588 6/7/2010 Removal Log 00207-2010REM

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 2000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 6/7/2010
OSFM First Notify Date: 5/7/1996 Abandoned Material:
Current Age: 23 Abandoned Date:
Install Date: 6/22/1987 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 6/22/1987

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Lining Materials Internal 8/15/2007 8/15/2012
Leak Detect - Piping European with No Test Req Suction N/A N/A
Leak Detect - Piping Sump Sensor
Leak Detect - Tank Automatic Tank Gauging OPW EECO 1500
Manway At Grade Accessible Manway Accessible at Grade N/A N/A
Overfill Prev Device Overfill Drop Tube Valve
Piping Fiberglass Double Wall N/A N/A
Spill Contain Device Manhole Field Constructed
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Leak Detect - Piping Sump Sensor Sensor Functional Pass 8/14/2007



Tank Number 2

Capacity: 250 Petroleum Use:
Product: Heating Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: State Removed Date: 8/13/2012
OSFM First Notify Date: Abandoned Material:
Current Age: Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 12/31/1973 Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 250 Petroleum Use:
Product: Heating Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: State Removed Date: 8/13/2012
OSFM First Notify Date: Abandoned Material:
Current Age: Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 12/31/1973 Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



MFD Motorfuel Dispensing Forms

No Forms Found