Owner Summary
Click for Facility/Tank Ownership history
| Owner Number |
Owner Name |
Owner Status |
Purchase Date |
| U0002560 |
Casey's Retail Company |
Current Owner |
5/14/2021 |
| U0036012 |
Buchanan Energy (S), LLC |
Former Owner |
12/9/2010 |
| U0010471 |
ExxonMobil Oil Corporation |
Former Owner |
|
Notice of Violations (Current)
NOV Number:
E0020261623
(Pending)
Issue Date:
6/24/2026
Expiration Date:
8/23/2026
View NOV Form
| Tanks |
Violations |
| Facility |
Farthest dispenser is greater than 40' and site lacks a communication system or system is inoperable - Dispenser 7/8 Intercom is not functioning.
175.210 h)The attendant shall at all times be able to communicate with persons in the dispensing area. Repair or replace intercom. |
NOV Number:
E0020261624
(Pending)
Issue Date:
6/24/2026
Expiration Date:
8/23/2026
View NOV Form
| Tanks |
Violations |
| 1, 2 |
Dispensers - hoses cracked, split or worn and require replacement - Replace main hose |
| 1, 2 |
Line interstitial sensors have been raised and rendered inoperational. - Sensors are raised in STP sumps.
Section 175.640 a)2) All new and existing sump sensors must be installed so as to detect liquid
per manufacturer's specifications or, if not specified by the manufacturer, at the lowest point in the sump. |
| 2 |
Miscellaneous - ATG is in alarm. L4 Fuel Alarm. |
| 2 |
Miscellaneous - ATG shows 4 gallons .79" of water in tank. |
| 2 |
Water in containment with required interstitial sensors - Remove water and repair containments to prevent water ingress. |
IEMA Numbers Associated with the Facility
No IEMA Numbers Found
LUST
Fund Eligibility and Deductibility Determinations
No Applications Found
Tank Number 1
| Capacity: |
20000 |
|
Petroleum Use: |
|
| Product: |
Gasoline - Regular |
|
CERCLA Substance: |
|
| Status: |
Currently in use |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
|
|
OSFM
First Notify Date: |
10/16/1996 |
|
Abandoned Material: |
|
| Current Age: |
29 |
|
Abandoned Date: |
|
| Install Date: |
5/31/1996 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
8/19/1996 |
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Flexible Non-Corrosive |
Not applicable |
Not applicable |
|
Corrosion Prot - Tank
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Leak Detect - Piping
|
Electronic Pressurized Line Leak Detection |
6/22/2026 |
6/22/2027 |
|
Leak Detect - Tank
|
Automatic Tank Gauging Veeder Root TLS 350 |
6/22/2026 |
6/22/2027 |
|
Leak Detect - Tank
|
Hydrostatic Reservoir Interstitial Monitoring Sensors |
6/22/2026 |
6/22/2027 |
|
Overfill Prev Device
|
Overfill Drop Tube Valve |
8/19/2024 |
8/19/2027 |
|
Piping
|
Flexible Double Wall Environ Geo Flex |
Not applicable |
Not applicable |
|
Piping
|
Single Wall STP/Tanktop Sump |
8/19/2024 |
8/19/2027 |
Leak Detect - Piping
|
Sump Sensor |
8/19/2024 |
8/19/2027 |
|
Spill Contain Device
|
Single Wall Spill Bucket |
8/19/2024 |
8/19/2027 |
|
Tank
|
Fiberglass Double Wall Fluid Containment Brine Filled |
Not applicable |
Not applicable |
Additional Tests
No Tests Listed
Tank Number 2
| Capacity: |
15000 |
|
Petroleum Use: |
|
| Product: |
Gasoline - Premium |
|
CERCLA Substance: |
|
| Status: |
Currently in use |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
|
|
OSFM
First Notify Date: |
10/16/1996 |
|
Abandoned Material: |
|
| Current Age: |
29 |
|
Abandoned Date: |
|
| Install Date: |
5/31/1996 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
8/19/1996 |
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Flexible Non-Corrosive |
Not applicable |
Not applicable |
|
Corrosion Prot - Tank
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Leak Detect - Piping
|
Electronic Pressurized Line Leak Detection |
6/22/2026 |
6/22/2027 |
|
Leak Detect - Tank
|
Automatic Tank Gauging Veeder Root TLS 350 |
6/22/2026 |
6/22/2027 |
|
Leak Detect - Tank
|
Hydrostatic Reservoir Interstitial Monitoring Sensors |
6/22/2026 |
6/22/2027 |
|
Overfill Prev Device
|
Overfill Drop Tube Valve |
8/19/2024 |
8/19/2027 |
|
Piping
|
Flexible Double Wall Environ Geo Flex |
Not applicable |
Not applicable |
|
Piping
|
Single Wall STP/Tanktop Sump |
8/19/2024 |
8/19/2027 |
Leak Detect - Piping
|
Sump Sensor |
8/19/2024 |
8/19/2027 |
|
Spill Contain Device
|
Single Wall Spill Bucket |
8/19/2024 |
8/19/2027 |
|
Tank
|
Fiberglass Double Wall Fluid Containment Brine Filled |
Not applicable |
Not applicable |
Additional Tests
| Equipment Type |
Equipment |
Test Type |
Test Result |
Test Date |
|
Piping
|
Flexible Double Wall Environ Geo Flex
|
Precision Test (Piping)
|
Pass
|
8/19/2024
|
Failed test = the latest test has failed.
Not applicable = a test does not apply to this equipment type or configuration.
No passing test found = a passing test is expected but was not found from the source data.
MFD
Motorfuel Dispensing Forms
No Forms Found