Facility Number: 2033927
Status: Active
Facility Name: Thornton's #116
Address: 1602 Essington Rd Joliet, IL 60435
County: Will
Property Parcel: 06-03-36-301-021-0000
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: AA01984
Green Tag Issue Date: 7/3/2025
Green Tag Expiration Date: 12/31/2027

Owner Details

Owner Name: Thorntons, LLC
Owner Address: 2600 James Thornton Way Louisville, KY 40245
Owner Status: Current Owner
Purchase Date: 5/9/2019
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 2/18/2026

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 7/3/2025 12/31/2027

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0039521 Thorntons, LLC Current Owner 5/9/2019
U0014995 Thornton's, Inc. - DO NOT USE THIS OWNER ID Former Owner 4/1/1995

Permits (Unexpired)

Click for permit history
Permit Number Type Status OSFM Receive Date Issue Date Expiration Date Documents
00709-2025UPG Upgrade Approved / Issued 6/6/2025 6/9/2025 12/9/2025 Documents

Notice of Violatlions (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 12000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 6/14/1995 Abandoned Material:
Current Age: 30 Abandoned Date:
Install Date: 4/11/1995 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 4/12/1995

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 3/5/2025 3/5/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 3/7/2025 3/7/2026
Overfill Prev Device Overfill Drop Tube Valve 3/5/2025 3/5/2028
Piping Fiberglass Single Wall Piping Ameron N/A N/A
Piping Single Wall STP/Tanktop Sump 3/7/2023 3/7/2026
Leak Detect - Piping Piping Sump Sensors Not Regulated N/A N/A
Piping Single Wall Transition Sump
Leak Detect - Piping Non-Discriminating Sump Sensor with positive shutdown 3/25/2021 3/25/2022
Leak Detect - Piping Non-Discriminating Sump Sensor with positive shutdown 4/26/2021 4/26/2022
Leak Detect - Piping Piping Sump Sensors Not Regulated N/A N/A
Spill Contain Device Double Wall Spill Bucket 3/7/2023 3/7/2026
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Ameron Precision Test (Piping) Pass 12/20/2022
Tank Fiberglass Single Wall Precision Test (Tank) Pass 3/7/2025



Tank Number 2

Capacity: 12000 Petroleum Use:
Product: E85 CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 6/14/1995 Abandoned Material:
Current Age: 30 Abandoned Date:
Install Date: 4/11/1995 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 4/12/1995

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 3/5/2025 3/5/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 3/5/2025 3/5/2026
Overfill Prev Device Overfill Drop Tube Valve 6/9/2025 6/9/2028
Piping Fiberglass Single Wall Piping Ameron N/A N/A
Piping Single Wall STP/Tanktop Sump 3/7/2023 3/7/2026
Leak Detect - Piping Piping Sump Sensors Not Regulated N/A N/A
Piping Single Wall Transition Sump
Leak Detect - Piping Non-Discriminating Sump Sensor with positive shutdown 3/25/2021 3/25/2022
Leak Detect - Piping Piping Sump Sensors Not Regulated N/A N/A
Spill Contain Device Double Wall Spill Bucket 6/9/2025 6/9/2028
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Tank Fiberglass Single Wall Precision Test (Tank) Pass 3/5/2025



Tank Number 3

Capacity: 12000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 6/14/1995 Abandoned Material:
Current Age: 30 Abandoned Date:
Install Date: 4/11/1995 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 4/12/1995

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 3/5/2025 3/5/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 3/5/2025 3/5/2026
Overfill Prev Device Overfill Drop Tube Valve 3/5/2025 3/5/2028
Piping Fiberglass Single Wall Piping Ameron N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated N/A N/A
Piping Single Wall Transition Sump
Leak Detect - Piping Non-Discriminating Sump Sensor with positive shutdown 3/25/2021 3/25/2022
Leak Detect - Piping Piping Sump Sensors Not Regulated N/A N/A
Spill Contain Device Double Wall Spill Bucket 3/7/2023 3/7/2026
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Tank Fiberglass Single Wall Precision Test (Tank) Pass 3/5/2025



Tank Number 4

Capacity: 6000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 6/14/1995 Abandoned Material:
Current Age: 30 Abandoned Date:
Install Date: 4/11/1995 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 4/12/1995

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 3/5/2025 3/5/2026
Leak Detect - Piping Siphon Bar N/A N/A
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 3/5/2025 3/5/2026
Overfill Prev Device Overfill Drop Tube Valve 3/5/2025 3/5/2028
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Fiberglass Single Wall Piping Ameron N/A N/A
Piping Single Wall STP/Tanktop Sump 3/7/2023 3/7/2026
Leak Detect - Piping Non-Discriminating Sump Sensor 4/9/2020 4/9/2021
Leak Detect - Piping Sump Sensor with positive shutdown 3/5/2025 3/5/2026
Piping Single Wall Transition Sump
Leak Detect - Piping Non-Discriminating Sump Sensor with positive shutdown 3/25/2021 3/25/2022
Leak Detect - Piping Piping Sump Sensors Not Regulated N/A N/A
Spill Contain Device Double Wall Spill Bucket 3/31/2023 3/31/2026
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Leak Detect - Piping Siphon Bar Functional Pass 4/9/2020
Tank Fiberglass Single Wall Precision Test (Tank) Pass 3/5/2025



Tank Number 5

Capacity: 6000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 6/14/1995 Abandoned Material:
Current Age: 30 Abandoned Date:
Install Date: 4/11/1995 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 4/12/1995

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Siphon Bar N/A N/A
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 3/5/2025 3/5/2026
Overfill Prev Device Overfill Drop Tube Valve 3/5/2025 3/5/2028
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 3/7/2023 3/7/2026
Leak Detect - Piping Non-Discriminating Sump Sensor 4/9/2020 4/9/2021
Leak Detect - Piping Sump Sensor with positive shutdown 3/5/2025 3/5/2026
Spill Contain Device Double Wall Spill Bucket 3/7/2023 3/7/2026
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Leak Detect - Piping Siphon Bar Functional Pass 4/9/2020
Tank Fiberglass Single Wall Precision Test (Tank) Pass 3/5/2025

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 12/27/2022 12/27/2025
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 11/12

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 12/27/2022 12/27/2025
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 13/14

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 12/27/2022 12/27/2025
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 15/16

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 12/27/2022 12/27/2025
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 17/18

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 12/27/2022 12/27/2025
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 19/20

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 12/27/2022 12/27/2025
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 12/27/2022 12/27/2025
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 12/27/2022 12/27/2025
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 12/27/2022 12/27/2025
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 9/10

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 12/27/2022 12/27/2025
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A