Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2033658
Status: Active
Facility Name: Valloor, Inc. BP
Address: 4257 W. 26th Street Chicago, IL 60623
County: Cook
Property Parcel:
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: AA02375
Green Tag Issue Date: 5/20/2025
Green Tag Expiration Date: 12/31/2027

Owner Details

Owner Name: Chackochan Kizhakkekuttu
Owner Address: 1600 S. Oak Park Avenue Berwyn, IL 60402
Owner Status: Current Owner
Purchase Date: 11/20/2011
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 1/13/2026

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 5/20/2025 12/31/2027

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0036690 Kizhakkekuttu, Chackochan Current Owner 11/20/2011
U0023494 A&J Gas, Inc., d/b/a Minuteman Former Owner 10/1/1988

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violatlions (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 10000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 10/28/1994 Abandoned Material:
Current Age: 36 Abandoned Date:
Install Date: 10/1/1988 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 6/1/1989

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Impressed Current Cathodic Protection 10/15/2024 10/15/2025
Corrosion Prot - Tank Impressed Current Cathodic Protection 10/15/2024 10/15/2025
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 3/27/2025 3/27/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 300 with CSLD 3/27/2025 3/27/2026
Overfill Prev Device Overfill Drop Tube Valve 4/7/2025 4/7/2028
Piping Steel Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 3/27/2025 3/27/2028
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Steel Single Wall Piping Precision Test (Piping) Pass 3/27/2025



Tank Number 2

Capacity: 10000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 10/28/1994 Abandoned Material:
Current Age: 36 Abandoned Date:
Install Date: 10/1/1988 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 6/1/1989

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Impressed Current Cathodic Protection 10/15/2024 10/15/2025
Corrosion Prot - Tank Impressed Current Cathodic Protection 10/15/2024 10/15/2025
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 3/27/2025 3/27/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 300 with CSLD 3/27/2025 3/27/2026
Overfill Prev Device Overfill Drop Tube Valve 4/7/2025 4/7/2028
Piping Steel Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 3/27/2025 3/27/2028
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Steel Single Wall Piping Precision Test (Piping) Pass 3/27/2025



Tank Number 3

Capacity: 3000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 10/28/1994 Abandoned Material:
Current Age: 36 Abandoned Date:
Install Date: 10/1/1988 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 6/1/1989

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Impressed Current Cathodic Protection 10/15/2024 10/15/2025
Corrosion Prot - Tank Impressed Current Cathodic Protection 10/15/2024 10/15/2025
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 10/15/2024 10/15/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 300 with CSLD 3/27/2025 3/27/2026
Overfill Prev Device Overfill Drop Tube Valve 3/27/2025 3/27/2028
Piping Steel Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 3/27/2025 3/27/2028
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Steel Single Wall Piping Precision Test (Piping) Pass 6/12/2023

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A

MFD Motorfuel Dispensing Forms

No Forms Found