Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2033538
Status: Installed/Not in Use
Facility Name: Exxon Mobil Oil Corp - Joliet Refinery
Address: 25915 S Frontage Road E. Channahon, IL 60410
County: Will
Property Parcel: 04-10-15-100-006-0000
Facility Type: Industrial / Manufacturing
Owner Type: Private
Green Tag Decal: Z001640
Green Tag Issue Date: 10/10/2024
Green Tag Expiration Date: 12/31/2026

Owner Details

Owner Name: Exxon Mobil Oil Corporation
Owner Address: 25915 S. Frontage Road C/O Joliet Refinery Channahon, IL 60410
Owner Status: Current Owner
Purchase Date:
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 4/19/2026

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Fleet 10/10/2024 12/31/2026

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0010471 Exxon Mobil Oil Corporation Current Owner
U0020466 Mobil Oil Former Owner 9/1/1982
U0030882 Exxon Mobil Oil Company Former Owner

Permits (Unexpired)

Click for permit history
Permit Number Type Status OSFM Receive Date Issue Date Expiration Date Documents
00721-2025INS Install Approved / Issued 6/3/2025 6/10/2025 12/10/2025 Documents
00659-2025REM Removal Approved / Issued 5/29/2025 5/29/2025 12/2/2025 Documents

Notice of Violatlions (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
2025-0439 6/17/2025 Removal Log 00659-2025REM

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 12000 Petroleum Use: None
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 6/17/2025
OSFM First Notify Date: 7/4/1986 Abandoned Material:
Current Age: 32 Abandoned Date:
Install Date: 9/1/1982 Red Tag Issue Date:
Last Used Date: 6/4/2025 Fee Due: $0.00
Product Date: 7/17/1992

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping American with Sensors/No Test Suction N/A N/A
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 Plus with CSLD 9/3/2024 9/3/2025
Overfill Prev Device Overfill Alarm 9/3/2024 9/3/2027
Overfill Prev Device Overfill Drop Tube Valve 9/3/2024 9/3/2027
Piping Fiberglass Double Wall Ameron N/A N/A
Piping Single Wall STP/Tanktop Sump 5/2/2025 5/2/2028
Leak Detect - Piping Sump Sensor 9/3/2024 9/3/2025
Spill Contain Device Single Wall Spill Bucket 9/3/2024 9/3/2027
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Leak Detect - Piping American with Sensors/No Test Suction Functional Pass 9/3/2024



Tank Number 2

Capacity: 8000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 6/17/2025
OSFM First Notify Date: 7/4/1986 Abandoned Material:
Current Age: 32 Abandoned Date:
Install Date: 9/1/1982 Red Tag Issue Date:
Last Used Date: 6/4/2025 Fee Due: $0.00
Product Date: 7/17/1992

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping European with No Test Req Suction N/A N/A
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 Plus with CSLD 9/3/2024 9/3/2025
Overfill Prev Device Overfill Alarm 9/3/2024 9/3/2027
Overfill Prev Device Overfill Drop Tube Valve 9/3/2024 9/3/2027
Piping Fiberglass Double Wall Ameron N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated N/A N/A
Spill Contain Device Single Wall Spill Bucket 9/3/2024 9/3/2027
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 600 Petroleum Use:
Product: Diesel Fuel CERCLA Substance: 1310732
Status: Does Not Exist CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 7/4/1986 Abandoned Material:
Current Age: 26 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 4

Capacity: 1000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Does Not Exist CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 7/4/1986 Abandoned Material:
Current Age: 26 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 5

Capacity: 12000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Installed/Not in Use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: Abandoned Material:
Current Age: 0 Abandoned Date:
Install Date: 6/24/2025 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 6

Capacity: 8000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Installed/Not in Use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: Abandoned Material:
Current Age: 0 Abandoned Date:
Install Date: 6/24/2025 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



Name\ID 1/2 diesel

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A



Name\ID 3/4 diesel

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A



Name\ID 4/5 gas

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A



Name\ID 6 gas

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A

MFD Motorfuel Dispensing Forms

Facility Number Name City Received Date Letter
2033538 Exxon Mobil Oil Corp - Joliet Refinery Channahon 06/04/2025 Letter Form