Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2031320
Status: Closed
Facility Name: Department Of Public Works
Address: 1440 Hillgrove Ave
Western Springs, IL 60558
County: Cook
Property Parcel: 18-05-300-025-0000
Facility Type: City / Town
Owner Type: Municipal
Green Tag Decal: V003877
Green Tag Issue Date: 7/30/2020
Green Tag Expiration Date: 6/17/2021

Owner Details

Owner Name: Village of Western Springs
Owner Address: 740 Hillgrove Avenue
Western Springs, IL 60558
Owner Status: Current Owner
Purchase Date: 1/1/1980
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 4/27/2022

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Fleet 9/26/2018 12/31/2020

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0016259 Village of Western Springs Current Owner 1/1/1980

Permits (Unexpired)

Click for permit history

No Active Permits Found

Deficiencies (Current)

No Deficiencies Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
91-3508 Eligible 3/3/1994 3/10/1994 $10,000
20210612 Eligible 7/19/2021 7/23/2021 $5,000 Letter
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 4000 Petroleum Use: None
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 6/16/2021
OSFM First Notify Date: 3/26/1986 Abandoned Material:
Current Age: 37 Abandoned Date:
Install Date: 12/1/1983 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 1/24/2020 1/24/2021
Leak Detect - Tank Automatic Tank Gauging OPW Site Sentinel 1 1/24/2020 1/24/2021
Overfill Prev Device Overfill Drop Tube Valve 7/9/2018 7/9/2021
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Spill Contain Device Single Wall Spill Bucket 12/26/2018 12/26/2021
Tank Fiberglass Single Wall N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test Fail 12/2/2020



Tank Number 2

Capacity: 4000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 6/16/2021
OSFM First Notify Date: 3/26/1986 Abandoned Material:
Current Age: 37 Abandoned Date:
Install Date: 12/1/1983 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 1/24/2020 1/24/2021
Leak Detect - Tank Automatic Tank Gauging OPW Site Sentinel 1 1/24/2020 1/24/2021
Overfill Prev Device Overfill Drop Tube Valve 7/9/2018 7/9/2021
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Spill Contain Device Single Wall Spill Bucket 12/26/2018 12/26/2021
Tank Fiberglass Single Wall N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test Pass 12/2/2020



Tank Number 3

Capacity: 2000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 10/26/1992
OSFM First Notify Date: 3/26/1986 Abandoned Material:
Current Age: 8 Abandoned Date:
Install Date: 12/1/1983 Red Tag Issue Date:
Last Used Date: 10/26/1992 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 4

Capacity: 2000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Abandoned in place CAS Code:
Regulated Status: Exempt Removed Date:
OSFM First Notify Date: 3/26/1986 Abandoned Material: Inert material mixed with portland cement
Current Age: Abandoned Date: 1/1/1980
Install Date: Red Tag Issue Date:
Last Used Date: 1/1/1980 Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A

MFD Motorfuel Dispensing Forms

No Forms Found