Facility Details
Facility Number:
2030715
Status:
Closed
Facility Name:
Quick Fuel Bridgeview
Address:
7555 West 79th Street
Bridgeview, IL 60455
County:
Cook
Property Parcel:
Facility Type:
Attended Self-Service Station
Owner Type:
Private
Green Tag Decal:
Q000638
Green Tag Issue Date:
8/4/2015
Green Tag Expiration Date:
12/31/2017
Owner Details
Owner Name:
Jacobus Energy, Inc.
Owner Address:
11815 West Bradley Road
DBA Quick Fuels
Milwaukee, WI 53224
Owner Status:
Current Owner
Purchase Date:
Type of Financial Responsibility:
Commercial Insurance
Financial Responsibility Reporting Due Date:
10/20/2016
Motor Fuel Dispensing Permits
MFD Permit Type
Issue Date
Expiration Date
Unattended Self Service
8/4/2015
12/31/2017
Fleet
10/29/2013
12/31/2015
Self Service
3/5/2009
12/31/2011
Owner Summary
Click for Facility/Tank Ownership history
Owner Number
Owner Name
Owner Status
Purchase Date
U0029778
Jacobus Energy, Inc.
Current Owner
U0016986
Quick Fuel
Former Owner
5/2/1991
Permits (Unexpired)
Click for permit history
No Active Permits Found
Notice of Violations (Current)
No Notice of Violations Found
IEMA Numbers Associated with the Facility
IEMA Number
Inspection Date
Inspection Type
Permit Number
16-0615
7/14/2016
Removal Log
00756-2016REM
LUST
Fund Eligibility and Deductibility Determinations
IEMA Number
Status
OSFM Received Date
OSFM Response Date
Deductible
Letter
16-0615
Eligible
9/9/2016
9/29/2016
$5,000
Pay Tank Fees Online
Tank Information
Tank Number 1
Capacity:
20000
Petroleum Use:
Product:
Diesel Fuel
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
7/14/2016
OSFM
First Notify Date:
5/15/1991
Abandoned Material:
Current Age:
24
Abandoned Date:
Install Date:
5/2/1991
Red Tag Issue Date:
Last Used Date:
7/5/2016
Fee Due:
$0.00
Product Date:
8/19/1991
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Fiberglass Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Fiberglass Non-Corrosive
N/A
N/A
Leak Detect - Piping
Mechanical Pressurized Line Leak Detection
10/24/2014
10/24/2015
Leak Detect - Piping
Sump Sensor
10/24/2014
10/24/2015
Leak Detect - Tank
Automatic Tank Gauging Veeder Root TLS 350
Overfill Prev Device
Ball Float Vent Valve
Piping
Fiberglass Double Wall
N/A
N/A
Spill Contain Device
Double Wall Spill Bucket
Tank
Fiberglass Double Wall
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 2
Capacity:
8000
Petroleum Use:
Product:
Gasoline
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
7/14/2016
OSFM
First Notify Date:
5/15/1991
Abandoned Material:
Current Age:
24
Abandoned Date:
Install Date:
5/2/1991
Red Tag Issue Date:
Last Used Date:
7/5/2016
Fee Due:
$0.00
Product Date:
8/19/1991
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Fiberglass Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Fiberglass Non-Corrosive
N/A
N/A
Leak Detect - Piping
Mechanical Pressurized Line Leak Detection
10/24/2014
10/24/2015
Leak Detect - Piping
Sump Sensor
10/24/2014
10/24/2015
Leak Detect - Tank
Automatic Tank Gauging Veeder Root TLS 350
Overfill Prev Device
Ball Float Vent Valve
Piping
Fiberglass Double Wall
N/A
N/A
Spill Contain Device
Double Wall Spill Bucket
Tank
Fiberglass Double Wall
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Dispenser Information
MFD
Motorfuel Dispensing Forms
No Forms Found