Notice of Violations (Current)
NOV Number:
E0020261653
(Pending)
Issue Date:
6/26/2026
Expiration Date:
8/25/2026
View NOV Form
| Tanks |
Violations |
| Facility |
Financial responsibility must be reported yearly - The form can be found at https://webapps.sfm.illinois.gov/USTPortal/Forms/FinancialResponsibility |
IEMA Numbers Associated with the Facility
No IEMA Numbers Found
LUST
Fund Eligibility and Deductibility Determinations
No Applications Found
Tank Number 1
| Capacity: |
2500 |
|
Petroleum Use: |
Back-up Generator |
| Product: |
Diesel Fuel |
|
CERCLA Substance: |
|
| Status: |
Currently in use |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
|
|
OSFM
First Notify Date: |
5/19/1992 |
|
Abandoned Material: |
|
| Current Age: |
35 |
|
Abandoned Date: |
|
| Install Date: |
8/1/1990 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
|
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Corrosion Prot - Tank
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Leak Detect - Piping
|
European with No Test Req Suction |
Not applicable |
Not applicable |
|
Leak Detect - Tank
|
Automatic Tank Gauging Veeder Root TLS - 4c |
6/11/2025 |
6/11/2026 |
|
Leak Detect - Tank
|
Hydrostatic Reservoir Interstitial Monitoring Sensors |
6/11/2025 |
6/11/2026 |
|
Overfill Prev Device
|
Overfill Drop Tube Valve |
6/11/2025 |
6/11/2028 |
|
Piping
|
Fiberglass Chase |
Not applicable |
Not applicable |
|
Piping
|
Copper Single Wall Piping |
Not applicable |
Not applicable |
|
Piping
|
Not Installed STP/Tanktop Sump |
Not applicable |
Not applicable |
|
Spill Contain Device
|
Single Wall Spill Bucket |
6/11/2025 |
6/11/2028 |
|
Tank
|
Fiberglass Double Wall Owens Corning |
Not applicable |
Not applicable |
Additional Tests
| Equipment Type |
Equipment |
Test Type |
Test Result |
Test Date |
|
Tank
|
Fiberglass Double Wall
|
Precision Test (Tank)
|
Pass
|
8/5/2022
|
Failed test = the latest test has failed.
Not applicable = a test does not apply to this equipment type or configuration.
No passing test found = a passing test is expected but was not found from the source data.
Dispenser Information
Failed test = the latest test has failed.
Not applicable = a test does not apply to this equipment type or configuration.
No passing test found = a passing test is expected but was not found from the source data.
MFD
Motorfuel Dispensing Forms
No Forms Found