Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2029445
Status: Closed
Facility Name: Fulton-Des Plaines Garage, Inc.
Address: 225 N. Des Plaines Street
Chicago, IL 60661
County: Cook
Property Parcel: 17-09-314-001-0000
Facility Type: Full Service Station
Owner Type: Private
Green Tag Decal: X001413
Green Tag Issue Date: 11/2/2022
Green Tag Expiration Date: 8/9/2023

Owner Details

Owner Name: Edward Tefka
Owner Address: 225 N. Des Plaines Street
Chicago, IL 60661
Owner Status: Current Owner
Purchase Date: 6/1/2023
Type of Financial Responsibility:
Financial Responsibility Reporting Due Date:

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Full Service 11/2/2022 12/31/2024
Self Service 4/17/2020 12/31/2022

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0041046 Tefka, Edward Current Owner 6/1/2023
U0018769 Fulton Des Plaines Garage & Serv Former Owner 9/17/1980

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
2023-0540 7/28/2023 Removal Log 00772-2023REM
2023-0540 7/27/2023 Removal Log 00772-2023REM

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
20230540 Eligible 11/9/2023 11/15/2023 $5,000 Letter
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 4000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 7/27/2023
OSFM First Notify Date: 2/26/1992 Abandoned Material:
Current Age: 56 Abandoned Date:
Install Date: 2/26/1967 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Lining Materials Internal 12/19/2018 12/19/2023
Leak Detect - Piping European with No Test Req Suction N/A N/A
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 300 6/21/2022 6/21/2023
Overfill Prev Device Overfill Drop Tube Valve 2/28/2020 2/28/2023
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 2/12/2020 2/12/2023
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 4000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 7/27/2023
OSFM First Notify Date: 2/26/1992 Abandoned Material:
Current Age: 56 Abandoned Date:
Install Date: 2/26/1967 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Lining Materials Internal 12/19/2018 12/19/2023
Leak Detect - Piping European with No Test Req Suction N/A N/A
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 300 6/21/2022 6/21/2023
Overfill Prev Device Overfill Drop Tube Valve 2/28/2020 2/28/2023
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 2/12/2020 2/12/2023
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 8000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 7/28/2023
OSFM First Notify Date: 2/26/1992 Abandoned Material:
Current Age: 43 Abandoned Date:
Install Date: 2/26/1980 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Lining Materials Internal 12/19/2018 12/19/2023
Leak Detect - Piping European with No Test Req Suction N/A N/A
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 300 6/21/2022 6/21/2023
Overfill Prev Device Overfill Drop Tube Valve 2/28/2020 2/28/2023
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 2/28/2020 2/28/2023
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



Name\ID 1

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 3

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A

MFD Motorfuel Dispensing Forms

No Forms Found